Publications by authors named "Susan C Scholes"

It has been proposed that an increased surface roughness of the femoral components of Total Knee Replacements (TKRs) may be a contributing factor to the accelerated wear of the polyethylene (PE) bearing and ultimately prosthesis failure. Oxidised Zirconium was introduced to the orthopaedic market in an attempt to reduce PE wear associated failures and increase the longevity of the prosthesis. In this study, non-contacting profilometry was used to measure the surface roughness of the femoral components of 6 retrieved TKRs (3 Oxidised Zirconium (OxZr) and 3 Cobalt Chromium alloy (CoCr) femoral components) and 2 as-manufactured femoral components (1 OxZr and 1 CoCr).

View Article and Find Full Text PDF

Background: Large-diameter (≥36-mm) metal-on-metal (MoM) total hip replacements have been shown to fail at an unacceptably high rate. Globally, the DePuy Pinnacle prosthesis was the most widely used device of this type. There is evidence to suggest that one of the main reasons for the poor clinical performance of large-diameter MoM prostheses is the metal debris released from the head-stem taper junction-i.

View Article and Find Full Text PDF

In contrast to the articulating and taper surfaces of failed total hip replacements, volumetric wear analysis of trunnions is not routinely performed. Metal wear particles from the trunnion may contribute not only to the failures of metal-on-metal total hip replacements but also to all hip replacements utilising metal trunnions. A validation study was performed with the material removed in stages from the trunnions of an Exeter V40 stem, a Corail stem and an Accolade stem to simulate different magnitudes of wear.

View Article and Find Full Text PDF

Purpose: With the advent of modular total knee arthroplasty (TKA) systems, backside wear at the articulation between the ultra-high-molecular-weight-polyethylene (UHMWPE) component undersurface and the tibial baseplate has received increasing attention as a source of clinically significant polyethylene wear debris. The aim of this study was to investigate the reciprocating interface at the TKA undersurface articulation using profilometry after in vivo service. Our null hypothesis was that there would be no discernible pattern or relationship between the metal tibial baseplate and UHMWPE surface profile.

View Article and Find Full Text PDF

The role of surface tension in the lubrication of metal-on-metal (CoCrMo alloy) hip resurfacings has been investigated to try to explain why all metal joints fail to be lubricated with simple water-based lubricants (sodium carboxymethyl cellulose), which have similar rheology to synovial fluid, but are lubricated with the same fluid with the addition of a proportion of bovine serum. As part of this study, surfactants, in the form of detergents, when added to carboxymethyl cellulose, have been shown to produce a predominantly fluid-film lubrication mechanism with friction even lower than the biological lubricant containing serum. Friction factors were reduced by 80% when a detergent was added to the lubricant.

View Article and Find Full Text PDF

Bovine serum is the lubricant recommended by several international standards for the wear testing of orthopaedic biomaterials; however, there are issues over its use due to batch variation, degradation, cost and safety. For these reasons, alternative lubricants were investigated. A 50-station Super-CTPOD (circularly translating pin-on-disc) wear test rig was used, which applied multidirectional motion to ultra-high-molecular-weight polyethylene test pins rubbing against cobalt chromium discs.

View Article and Find Full Text PDF

With greater numbers of primary knee replacements now performed in younger patients there is a demand for improved performance. Surface roughness of the femoral component has been proposed as a causative mechanism for premature prosthesis failure. Nineteen retrieved total knee replacements were analysed using a non-contacting profilometer to measure the femoral component surface roughness.