Background: The optimal mode of fixation in total knee arthroplasty is a continuing subject of debate.
Methods: Previously, we reported 2-year results for this prospective, randomized trial. Knee Society Scores, Oxford scores, and pain visual analog scales were collected pre-operatively and post-operatively.
Background: Crosslinked polyethylene (XLPE) liners used for primary THA have demonstrated lower wear rates than noncrosslinked, conventional polyethylene (CPE) liners through the first decade of clinical service. However, little high-quality evidence is currently available regarding the second decade performance of these implants and it remains uncertain whether the onset of osteolysis has simply been delayed or if the wear associated with XLPE liners will remain low enough that osteolysis will not occur. It is also unknown how the potential reductions in wear and osteolysis will influence long-term revision rates.
View Article and Find Full Text PDFBackground: Hard-on-hard bearings for total hip arthroplasty continue to warrant analysis even though crosslinked polyethylene is performing very well. Ceramic-on-metal (CoM) has low in vitro wear and did well in an early clinical trial. We report on a prospective, randomized, multicenter investigational device trial comparing CoM with metal-on-metal (MoM).
View Article and Find Full Text PDFThe optimal mode of fixation in total knee arthroplasty (TKA) is a subject of debate. We enrolled 100 TKA patients randomized to cemented or cementless fixation. Knee Society Scores (KSS), Oxford scores and pain visual analog scales (VAS) were collected pre-operatively and post-operatively.
View Article and Find Full Text PDFIn 1999, our institution initiated a prospective study to compare the outcome of total hip arthroplasty patients randomized to either non-cross-linked liners or polyethylene liners that were cross-linked with 5.0 Mrad of gamma-irradiation and heat treated to eliminate free radicals. Among 230 randomized THAs, 13 have had reoperations, and 31 patients with 32 THAs died with less than 9-year follow-up.
View Article and Find Full Text PDFHigh-flexion total knee arthroplasty (TKA) designs have been available for several years for patients desiring a greater postoperative flexion. We conducted a focused review on published results of prospective, randomized clinical trials that compared a standard posterior-stabilized TKA with a high-flexion posterior-stabilized TKA design. Follow-up ranged from 1 to 2.
View Article and Find Full Text PDFWe sought to determine if the rotating platform (RP) high-flex design provides improved flexion compared with the standard RP total knee. A total of 142 patients were randomized to receive an RP flex (RP-F) or RP TKA. Supine flexion was measured with a goniometer and lateral x-ray.
View Article and Find Full Text PDFBackground: Previously described molecular biology techniques used to detect periprosthetic infections have been complicated by false-positive results. We have reported the development of a messenger RNA (mRNA)-based procedure to reduce these false-positive results. The limitations of this procedure are the lack of a universal target and reduced sensitivity due to a low concentration of bacterial mRNAs in test samples.
View Article and Find Full Text PDFUnlabelled: Metal-on-metal bearing total hip arthroplasty is performed more commonly than in the past. There may be manufacturing differences such as clearance, roughness, metallurgy, and head size that affect performance. In a prospective, randomized trial, we compared 2-year postoperative ion levels for a 28-mm metal-on-polyethylene bearing with 28-mm and 36-mm metal-on-metal bearings.
View Article and Find Full Text PDF