J Appl Clin Med Phys
March 2022
Purpose: Detector arrays and profile-scans have widely replaced film-measurements for quality assurance (QA) on linear accelerators. Film is still used for relative output factor (ROF) measurements, positioning, and dose-profile verification for annual Leksell Gamma Knife (LGK) QA. This study shows that small-field active detector measurements can be performed in the easily accessed clinical mode and that they are an effective replacement to time-consuming and exacting film measurements.
View Article and Find Full Text PDFThe purpose of this work is to establish an automated approach for a multiple isocenter volumetric arc therapy (VMAT)-based TBI treatment planning approach. Five anonymized full-body CT imaging sets were used. A script was developed to automate and standardize the treatment planning process using the Varian Eclipse v15.
View Article and Find Full Text PDFThe American Association of Physicists in Medicine (AAPM) has established a comprehensive Code of Ethics for its members. The Code is a formal part of AAPM governance, maintained as Professional Policy 24, and includes both principles of ethical practice and the rules by which a complaint will be adjudicated. The structure and content of the Code have been crafted to also serve the much broader purpose of giving practical ethical guidance to AAPM members for making sound decisions in their professional lives.
View Article and Find Full Text PDFThe goal of this study was to implement and validate a noninvasive, quantitative ultrasonic technique for accurate and reproducible measurement of normal-tissue toxicity in radiation therapy. The authors adapted an existing ultrasonic tissue characterization (UTC) technique that used a calibrated 1D spectrum based on region-of-interest analysis. They modified the calibration procedure by using a reference phantom instead of a planar reflector.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
May 2008
Skin injury is a common side effect of breast-cancer radiation therapy. Although physicians often observe skin toxicity, quantifying its severity remains a challenge. We present a novel quantitative ultrasonic technique to evaluate skin changes associated with radiotherapy.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
February 2007
Purpose: To investigate how the performance characteristics of ultrasound tissue typing (UTT) affect the design of a population-based prostate dose-painting protocol.
Methods And Materials: The performance of UTT is evaluated using the receiver operating characteristic curve. As the imager's sensitivity increases, more tumors are detected, but the specificity worsens, causing more false-positive results.
A detailed understanding of non-targeted normal tissue response is necessary for the optimization of radiation treatment plans in cancer therapy. In this study, we evaluate the ability of electrical impedance spectroscopy (EIS) to non-invasively determine and quantify the injury response in soft tissue after high dose rate (HDR) irradiation, which is characterized by large localized dose distributions possessing steep spatial gradients. The HDR after-loading technique was employed to irradiate small volumes of muscle tissue with single doses (26-52 Gy targeted 5 mm away from the source).
View Article and Find Full Text PDF