Objectives: Exposure to humidifier disinfectants has been linked to respiratory diseases, including interstitial lung disease, asthma, and pneumonia. Consequently, numerous toxicological studies have explored respiratory damage as both a necessary and sufficient condition for these diseases. We systematically reviewed and integrated evidence from toxicological studies by applying the evidence integration method established in previous research to confirm the biological plausibility of the association between exposure and disease.
View Article and Find Full Text PDFDissolved organic matter (DOM) in river watersheds dynamically changes based on its source during a monsoon period with storm event. However, the variations in DOM in urban and rural river watersheds that are dominated by point and non-point sources have not been adequately explored to date. We developed an innovative approach to reveal DOM sources in complex river watershed systems during pre-monsoon, monsoon, and post-monsoon periods using end-member mixing analysis (EMMA) by combining multi-isotope values (δC-DOC, δN-NO and δO-NO) and spectroscopic indices (fluorescence index [FI], biological index [BIX], humification index [HIX], and specific UV absorbance [SUVA]).
View Article and Find Full Text PDFThe Ministry of Environment, South Korea, is involved in efforts to reduce safety-related accidents that could occur during hazardous waste disposal and minimise the environmental impacts of waste disposal. To reach such goals, new factors have been added that contribute to the hazardous characteristics of hazardous waste. The Ministry is also expanding regulations on inorganic and organic components present in hazardous waste for these factors and continues to correct the classification system to establish standards for waste components.
View Article and Find Full Text PDFIn this study, we compared the results of biomass and biocarbon content analysis of Solid Refuse Fuels using C method and selective dissolution method. Solid Refuse fuel Samples for biomass and biocarbon contents analysis were each collected from the silos and stack of the respective three facilities. Samples collected for 1, 10, 20, and 30 days for each method were analyzed.
View Article and Find Full Text PDFKorea's Ministry of Environment has implemented the Framework Act on Resource Recirculation to activate waste resource recovery. However, industrial waste treatment facilities have some problems related to diversity of waste received for proper management of wastes. Waste incineration facilities are required to receive and process combustible waste and are forbidden to re-consign waste to other waste treatment facilities without any processing.
View Article and Find Full Text PDFThe Ministry of Environment, Republic of Korea has implemented the "Framework Act on Resource Recirculation" to activate waste resource recovery. However, industrial waste treatment facilities have some problems related to diversity of waste received for proper management of wastes. Waste incineration facilities are required to receive and process combustible waste and are forbidden to re-consign waste to other waste treatment facilities without any processing.
View Article and Find Full Text PDFManagement of solid recovered fuel (SRF) in South Korea is unique from most other countries in that it is based on a single standard. All SRFs are distributed at the same price irrespective of their performance, resulting in utilization problems and a low degree of acceptance among consumers. Moreover, the difficulty of temperature maintenance during transportation, excessive ash content, and the use of inappropriate microwave acid digestion methods pose challenges to SRF reliability.
View Article and Find Full Text PDFThis study examines the new policy framework, which includes effective environmental assessment procedure to manage waste in Korea. Concept of this framework pursues the important strategies toward the waste reduction, preservation of landfill area, stabilization and removal of hazardous substance in wastes, and optimal treatment for energy and material recovery from wastes. Therefore, it has begun on three points.
View Article and Find Full Text PDFToxic polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in 45 stack gas samples were measured from 19 medical waste incinerators in South Korea using high-resolution gas chromatography equipped with a high-resolution mass spectrometer. The average concentrations of the sum of 17 toxic PCDD/PCDF congeners emitted from the medical waste incinerators ranged from 0.153 to 101.
View Article and Find Full Text PDFThis study investigated 24 pharmaceuticals compounds belonging to the classes of analgesics, stimulants, anti-seizures, non-steroidal anti-inflammatory drugs (NSAIDs), and antibiotics in the sludge of 12 municipal sewage treatment plants (S-sludge) and 4 livestock wastewater treatment plants (L-sludge) located across Korea. Over 70% of the target compounds were detected in at least one sample of S-sludge and L-sludge. The total concentration of the target pharmaceutical compounds detected in S-sludge was 2.
View Article and Find Full Text PDFThis study focused on a quantitative substance flow analysis (SFA) of polybrominated diphenyl ethers (PBDEs) in plastics from obsolete TVs and computer monitors that often contain large amounts of the flame retardants. According to the results of the static SFA study, 1.87 tons and 0.
View Article and Find Full Text PDFThe emission rates of polybrominated diphenyl ethers (PBDEs) from electric/electronic products during their use and disposal were estimated. E-wastes, including televisions and refrigerators, gathered at recycling centers were also analyzed to estimate their emissions. The average concentrations of PBDEs in TV rear covers produced before and after the year 2000 were 145,027 mg/kg and 14,049 mg/kg, respectively.
View Article and Find Full Text PDFWe measured five estrogens in the wastewater samples from the municipal wastewater treatment plants (M-WWTPs), livestock wastewater treatment plants (L-WWTPs), hospital WWTPs (H-WWTPs) and pharmaceutical manufacture WWTPs (P-WWTPs) in Korea. The L-WWTPs showed the highest total concentration (0.195-10.
View Article and Find Full Text PDFTwenty-four pharmaceuticals were measured in wastewater from 12 municipal wastewater treatment plants (M-WWTPs), four livestock WWTPs (L-WWTPs), four hospital WWTPs (H-WWTPs) and four pharmaceutical manufacture WWTPs (P-WWTPs). The total concentration of pharmaceuticals in the influent samples was highest in the L-WWTPs followed by the P-WWTPs, H-WWTPs and M-WWTPs. The effluents had different patterns of pharmaceuticals than their corresponding influents because of the different fate of each compound in the WWTPs.
View Article and Find Full Text PDFSince South Korea ratified Stockholm Convention in January 2007, there is an obligation to survey the national emission of PCDD/Fs through environmental routes other than the air for taking actions to reduce and/or eliminate the release of PCDD/Fs. In this study, PCDD/F-containing wastes from various industrial emission sources in Korea (n=388) except from incinerators were investigated to elucidate the emission characteristics and their emission factors of PCDD/Fs in each industry. The concentrations of PCDD/Fs in waste samples ranged ND-96,200 ng I-TEQ kg(-1) (or 66,600 ng WHO-TEQ kg(-1)) for solid phase samples and ND-11,100 pg I-TEQL(-1) (or 6800 ng WHO-TEQ L) for liquid samples, respectively.
View Article and Find Full Text PDFTo examine the levels of PCDD/DFs pollution in environmental samples in the vicinity of various incinerators, the levels of PCDD/DFs in air and soil samples collected near 17 incinerators and stack emission gases were investigated between 2003 and 2006. A total of 434 soil, 28 stack emission gas, and 38 air samples were analyzed for their PCDD/DFs concentrations. The PCDD/DFs concentrations in the flue gas samples ranged from 0.
View Article and Find Full Text PDFIn the present study, individual PCB congeners were determined in the flue gases of 10 industrial and 5 municipal solid waste incinerators using HRGC/HRMS. The total PCBs concentration of all congeners (168 tetra to deca-chlorinated congeners) ranged from 26 to 343 ng/Nm(3), and from 36 to 1095 ng/Nm(3) in industrial waste incinerators (IWI) and municipal solid waste incinerators (MSWI), respectively. The total TEQ concentrations of PCBs, calculated using WHO-TEF values, varied from 0.
View Article and Find Full Text PDF