Demonstrated is a standalone RF self-interference canceller for simultaneous transmit and receive (STAR) magnetic resonance imaging (MRI) at 1.5T. Standalone STAR cancels the leakage signal directly coupled between transmit and receive RF coils.
View Article and Find Full Text PDFThe radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise ratio (SNR) at the receive signal chain are directly dependent on the impedance matching condition presented by a loaded coil, tuned to the Larmor frequency. Sub-optimal impedance condition of receive coils significantly reduces coil sensitivity and image quality. In this study we propose a Standalone Wireless Impedance Matching (SWIM) system for RF coils to automatically compensate for the impedance mismatch caused by the loading effect at the target frequency.
View Article and Find Full Text PDFIEEE Antennas Wirel Propag Lett
October 2022
Magnetic resonance imaging (MRI) requires spatial uniformity of the radiofrequency (RF) field inside the subject for maximum signal-to-noise ratio (SNR) and image contrast. Bulky high permittivity dielectric pads (HPDPs) focus magnetic fields into the region of interest (ROI) and increase RF field uniformity when placed between the patient and RF coils in the MR scanner. Metamaterials could replace HPDPs and reduce system bulkiness, but those in the literature often require a complicated fabrication process and cannot conform to patient body shape.
View Article and Find Full Text PDFMedicine (Baltimore)
December 2021
Rationale: Complications from COVID-19 vaccines have yet to be sufficiently analyzed because they are rapidly approved without long-term data. In particular, there are no case reports of lymphedema in a healthy patient following vaccination. Herein, we report a patient who underwent transient lymphedema after vaccination with BNT16b2.
View Article and Find Full Text PDFBackground: The umbilicus is a key aesthetic unit of the abdominal wall. It contributes to the natural curvature of the abdomen and is now considered as one of the most important factors in the overall results and patient satisfaction. In this study, we present an inverted-U incisional technique for umbilicoplasty.
View Article and Find Full Text PDFJ Plast Surg Hand Surg
August 2020
In end-to-side vessel-anastomoses, a side fenestration should be made by a slit incision or partial excision of the vessel wall. However, a slit incision might restrict blood flow across the anastomosis, and a partial vessel wall excision using micro-scissors may be time-consuming and result in irregular edges, which may weaken the vessel wall and cause flow disturbances. We used a biopsy punch for end-to-side anastomosis, and obtained satisfactory results.
View Article and Find Full Text PDFPurpose: Deep brain stimulation electrodes composed of carbon fibers were tested as a means of administering and imaging magnetic resonance electrical impedance tomography (MREIT) currents. Artifacts and heating properties of custom carbon-fiber deep brain stimulation (DBS) electrodes were compared with those produced with standard DBS electrodes.
Methods: Electrodes were constructed from multiple strands of 7-μm carbon-fiber stock.
In acquired immunodeficiency syndrome (AIDS) patients, immune reconstitution inflammatory syndrome (IRIS) due to complex (MAC) infection is one of the most difficult IRIS types to manage. We report an unusual case of MAC-associated IRIS. At first the patient was diagnosed human immunodeficiency virus (HIV) infection after he was admitted with pneumocystis pneumonia.
View Article and Find Full Text PDFCongenital cardiovascular anomalies, such as dextrocardia, persistent left superior vena cava (SVC), and pulmonary artery (PA) sling, are rare disorders. These congenital anomalies can occur alone, or coincide with other congenital malformations. In the majority of cases, congenital anomalies are detected early in life by certain signs and symptoms.
View Article and Find Full Text PDFIEEE Trans Microw Theory Tech
October 2016
A mixed infection of (Mab) and (MTB) in the lung is an unusual clinical manifestation and has not yet been reported. A 61-year-old woman had been treated for Mab lung disease and concomitant pneumonia, and was diagnosed with pulmonary tuberculosis (PTB). Despite both anti-PTB and anti-Mab therapy, her entire left lung was destroyed and collapsed.
View Article and Find Full Text PDFPurpose: To present a practical scheme of a simultaneous radiofrequency (RF) transmit (Tx) and receive (Rx) (STAR) system for MRI, discuss the challenges and solutions, and show preliminary in vivo MR images obtained with this new technique.
Methods: A remotely controlled STAR system was built and tested with a transverse electromagnetic head coil on a 4T (Oxford, 90 cm-bore) MRI scanner equipped with an Agilent DirectDrive console (Agilent, Santa Clara, CA). In vivo head images have been acquired using continuous sweep excitation and acquisition.
IEEE Trans Microw Theory Tech
August 2014
Higher magnetic field strength in magnetic resonance imaging (MRI) systems offers higher signal-to-noise ratio (SNR), contrast, and spatial resolution in MR images. However, the wavelength in ultra-high fields (7 tesla and beyond) becomes shorter than the human body at the Larmor frequency with increasing static magnetic field (B) of MRI system. At short wavelengths, interference effect appears resulting in non- uniformity of the RF magnetic near-field (B) over the subject and MR images may have spatially anomalous contrast.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
October 2015
Magnetic resonance imaging (MRI) is a widely used nonionizing and noninvasive diagnostic instrument to produce detailed images of the human body. The radio-frequency (RF) coil is an essential part of MRI hardware as an RF front-end. RF coils transmit RF energy to the subject and receive the returning MR signal.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
February 2014
Multi-element volume radio-frequency (RF) coils are an integral aspect of the growing field of high-field magnetic resonance imaging. In these systems, a popular volume coil of choice has become the transverse electromagnetic (TEM) transceiver coil consisting of microstrip resonators. In this paper, to further advance this design approach, a new microstrip resonator strategy in which the transmission line is segmented into alternating impedance sections, referred to as stepped impedance resonators (SIRs), is investigated.
View Article and Find Full Text PDF