Natural killer (NK) cells are a crucial component of the innate immune system. This study introduces Cellytics NK, a novel platform for rapid and precise measurement of NK cell activity. This platform combines an NK-specific activation stimulator cocktail (ASC) and lens-free shadow imaging technology (LSIT), using optoelectronic components.
View Article and Find Full Text PDFAccurate and efficient classification and quantification of CD34+ cells are essential for the diagnosis and monitoring of leukemia. Current methods, such as flow cytometry, are complex, time-consuming, and require specialized expertise and equipment. This study proposes a novel approach for the label-free identification of CD34+ cells using a deep learning model and lens-free shadow imaging technology (LSIT).
View Article and Find Full Text PDFFluorescent microbeads (MBs) are widely used as next-generation biosensors for the detection of target chemicals at highly sensitive concentrations, and for imaging and tracking and . However, most known methods for producing fluorescent MBs require complicated multistep processes that result in low production rates. In this study, we report a method for fabricating micrometer-sized quantum dot microbeads (QD-MBs) using a microfluidic chip and specially designed QD photoresist (QD-PR).
View Article and Find Full Text PDFNanomaterials (Basel)
July 2023
Micro/nano patterns based on quantum dots (QDs) are of great interest for applications ranging from electronics to photonics to sensing devices for biomedical purposes. Several patterning methods have been developed, but all lack the precision and reproducibility required to fabricate precise, complex patterns of less than one micrometer in size, or require specialized crosslinking ligands, limiting their application. In this study, we present a novel approach to directly pattern QD nanopatterns by electron beam lithography using commercially available colloidal QDs without additional modifications.
View Article and Find Full Text PDFSmartphone-based point-of-care testing (POCT) is rapidly emerging as an alternative to traditional screening and laboratory testing, particularly in resource-limited settings. In this proof-of-concept study, we present a smartphone- and cloud-based artificial intelligence quantitative analysis system (SCAISY) for relative quantification of SARS-CoV-2-specific IgG antibody lateral flow assays that enables rapid evaluation (<60 s) of test strips. By capturing an image with a smartphone camera, SCAISY quantitatively analyzes antibody levels and provides results to the user.
View Article and Find Full Text PDFPlasmonics is the study of surface plasmons formed by the interaction of incident light with electrons to form a surface-bound electromagnetic wave [...
View Article and Find Full Text PDFThe accidental spill of hazardous and noxious substances (HNSs) in the ocean has serious environmental and human health consequences. Assessing the ecotoxicity of seawater exposed to various HNS is challenging due to the constant development of new HNS or mixtures, and assessment methods are also limited. Microalgae viability tests are often used among the various biological indicators for ecotoxicity testing, as they are the primary producers in aquatic ecosystems.
View Article and Find Full Text PDFQuantum dots (QDs) have emerged as an important class of materials for diverse applications such as solid-state lighting, energy conversion, displays, biomedicine, and plasmonics due to their excellent photonic properties and durability. Soft lithography, inkjet printing, nanoimprinting, and polymer deep-pen lithography are primary lithography techniques employed to implement micro-patterns with QDs, however, there are limited reports on QD photolithography using conventional photolithography processes suitable for mass production. This study reports a QD photolithography technique using a custom-developed QD photoresist made of an organic-inorganic hybrid coating layer.
View Article and Find Full Text PDFThe lens-free shadow imaging technique (LSIT) is a well-established technique for the characterization of microparticles and biological cells. Due to its simplicity and cost-effectiveness, various low-cost solutions have been developed, such as automatic analysis of complete blood count (CBC), cell viability, 2D cell morphology, 3D cell tomography, etc. The developed auto characterization algorithm so far for this custom-developed LSIT cytometer was based on the handcrafted features of the cell diffraction patterns from the LSIT cytometer, that were determined from our empirical findings on thousands of samples of individual cell types, which limit the system in terms of induction of a new cell type for auto classification or characterization.
View Article and Find Full Text PDFThe complete blood count (CBC) is one of the most important clinical steps in clinical diagnosis. The instruments used for CBC are usually expensive and bulky and require well-trained operators. Therefore, it is difficult for medical institutions below the tertiary level to provide these instruments, especially in underprivileged countries.
View Article and Find Full Text PDFThe refractive index (RI), an important optical property of a material, is measured by commercial refractometers in the food, agricultural, chemical, and manufacturing industries. Most of these refractometers must be equipped with a prism for light dispersion, which drastically limits the design and size of the refractometer. Recently, there have been several reports on the development of a surface plasmon resonance (SPR)-based RI detector, which is characterized by its high sensitivity and simplicity.
View Article and Find Full Text PDFThis paper demonstrates a commercial-level field-portable lens-free cell analyzer called the NaviCell (No-stain and Automated Versatile Innovative cell analyzer) capable of automatically analyzing cell count and viability without employing an optical microscope and reagents. Based on the lens-free shadow imaging technique, the NaviCell (162 × 135 × 138 mm³ and 1.02 kg) has the advantage of providing analysis results with improved standard deviation between measurement results, owing to its large field of view.
View Article and Find Full Text PDFWe demonstrate a flexible strain-gauge sensor and its use in a wearable application for heart rate detection. This polymer-based strain-gauge sensor was fabricated using a double-sided fabrication method with polymer and metal, i.e.
View Article and Find Full Text PDFThe incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels.
View Article and Find Full Text PDFRecently, lens-free imaging has evolved as an alternative imaging technology. The key advantages of this technology, including simplicity, compactness, low cost, and flexibility of integration with other components, have facilitated the realization of many innovative applications, especially, in the fields of the on-chip lens-free imaging and sensing. In this review, we discuss the development of lens-free imaging, from theory to applications.
View Article and Find Full Text PDFLens-free imaging technology has been extensively used recently for microparticle and biological cell analysis because of its high throughput, low cost, and simple and compact arrangement. However, this technology still lacks a dedicated and automated detection system. In this paper, we describe a custom-developed automated micro-object detection method for a lens-free imaging system.
View Article and Find Full Text PDFJ Microbiol Methods
December 2014
A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive.
View Article and Find Full Text PDFFor monitoring of human cellular response to repetitive bacterial stimulations (e.g., Pseudomonas aeruginosa in a lysate form), we devised a chemiluminescent immuno-analytical system for toll-like receptor 1 (TLR1) as marker present on cell surfaces (e.
View Article and Find Full Text PDFA label-free immunosensing method based on the conformational change of calcium-binding protein (CBP) depending on analyte concentration was explored for semi-continuous analysis of free Ca(2+). Glucose-galactose-binding protein as a CBP and produced as a recombinant protein by Escherichia coli was used as the immunogen to produce monoclonal antibodies by hybridoma technology. We finally screened the 3-6F cell clone, which produced the desired antibody specific to a particular structural conformation of the protein that occurred only upon CBP-calcium complex formation.
View Article and Find Full Text PDFIn this study, a novel mammalian cell receptor-based immuno-analytical method was developed for the detection of food-poisoning microorganisms by employing toll-like receptors (TLRs) as sensing elements. Upon infection with bacterium, the host cells respond by expressing TLRs, particularly TLR1, TLR2, and TLR4, on the outer membrane surfaces. To demonstrate the potential of using this method for detection of foodborne bacteria, we initially selected two model sensing systems, expression of TLR1 on a cell line, A549, for Escherichia coli and TLR2 on a cell line, RAW264.
View Article and Find Full Text PDFBiosens Bioelectron
December 2012
A high-throughput continuous cell monitoring technique which does not require any labeling reagents or destruction of the specimen is demonstrated. More than 6000 human alveolar epithelial A549 cells are monitored for up to 72 h simultaneously and continuously with a single digital image within a cost and space effective lens-free shadow imaging platform. In an experiment performed within a custom built incubator integrated with the lens-free shadow imaging platform, the cell nucleus division process could be successfully characterized by calculating the signal-to-noise ratios (SNRs) and the shadow diameters (SDs) of the cell shadow patterns.
View Article and Find Full Text PDFBiosens Bioelectron
September 2012
A flexible glucose sensor using a CVD-grown graphene-based field-effect-transistor (FET) is demonstrated. The CVD-grown graphene was functionalized with linker molecules in order to immobilize the enzymes that induce the catalytic response of glucose. Polyethylene terephthalate (PET) was employed as the substrate material to realize a flexible sensor.
View Article and Find Full Text PDFGeneration of minimally diffracting beam arrays in the midfield region using periodic metal annular apertures is investigated. The relations between the patterns of the diffraction fields and the structural parameters of the periodic metal annular aperture are numerically analyzed. Material dependent transmission characteristics are also studied with finite difference time-domain simulation.
View Article and Find Full Text PDF