Background: In ovo MR presents a promising and viable alternative to traditional in vivo small animal experiments. Sodium MRI complements proton MRI by providing potential access to tissue cellular metabolism. Despite its abundance, sodium MRI is challenged by lower MR sensitivity and faster relaxation times compared to proton MRI.
View Article and Find Full Text PDFThis study presents a novel MRI coil design approach explicitly tailored for chick embryo measurements, with the primary objective of improving sensitivity and coverage. The limitations posed by conventional birdcage coils were addressed by introducing a curvature feature into a standard coil. The performance of the modified coil was assessed using EM simulations and experimental evaluations, which were subsequently validated using a 7 T MRI scanner.
View Article and Find Full Text PDFA polyurethane series (PHEI-PU) was prepared via a one-shot bulk polymerization method using hexamethylene diisocyanate (HDI), polycarbonate diol (PCD), and isosorbide derivatives (ISBD) as chain extenders. The mechanical properties were evaluated using a universal testing machine (UTM), and the thermal properties were evaluated using thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The PHEI-PU series exhibited excellent mechanical properties with an average tensile strength of 44.
View Article and Find Full Text PDFIEEE Trans Med Imaging
May 2023
MR measurement using a combination of X-nuclei and proton MRI is of great interest as the information provided by the two nuclei is highly complementary, with the X-nuclei signal giving metabolic data relating to potential biomarkers and the proton signal affording anatomical details. Due to the relatively weak signal obtained from X-nuclei, combining an X-nuclei coil with a proton coil is also advantageous for [Formula: see text] shimming and scout images. One approach to building a double-resonant coil is to modify the coil geometry.
View Article and Find Full Text PDFIsosorbide is a bio-based renewable resource that has been utilized as a stiffness component in the synthesis of novel polymers. Modified isosorbide-based bis(2-hydroxyethyl)isosorbide (BHIS) has favorable structural features, such as fused bicyclic rings and a primary hydroxyl function with improved reactivity to polymerization when compared to isosorbide itself. Polyurethane series (PBH PU series) using polycarbonate diol (PCD) and bis(2-hydroxyethyl)isosorbide (BHIS) were polymerized through a simple, one-shot polymerization without a catalyst using various ratios of BHIS, PCD, and hexamethylene diisocyanate (HDI).
View Article and Find Full Text PDFNovel polycaprolactone-based polyurethane (PCL-PU) copolymers with hyperelasticity, shape-memory, and ultra-cell-adhesion properties are reported as clinically applicable tissue-regenerative biomaterials. New isosorbide derivatives (propoxylated or ethoxylated ones) were developed to improve mechanical properties by enhanced reactivity in copolymer synthesis compared to the original isosorbide. Optimized PCL-PU with propoxylated isosorbide exhibited notable mechanical performance (50 MPa tensile strength and 1150% elongation with hyperelasticity under cyclic load).
View Article and Find Full Text PDFIEEE Trans Med Imaging
May 2022
Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept.
View Article and Find Full Text PDFWith the increasing availability of ultra-high field MRI systems, studying non-proton nuclei (X-nuclei), such as Na and P has received great interest. X-nuclei are able to provide insight into important cellular processes and energy metabolism in tissues and by monitoring these nuclei closely it is possible to establish links to pathological conditions and neurodegenerative diseases. In order to investigate X-nuclei, a well-designed radiofrequency (RF) system with a multi-tuned RF coil is required.
View Article and Find Full Text PDFProstate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances.
View Article and Find Full Text PDFProton magnetic resonance imaging (MRI) can be combined with signals from non-proton nuclei (X-nuclei) to provide metabolic information. Double-resonant coils are often used for X-nuclei MR studies where the proton element is employed for scout imaging and B shimming. This work describes the development of a new double-resonant coil capable of operating at both proton and X-nuclei frequencies.
View Article and Find Full Text PDFPurpose: Functional MRI (fMRI) is a well-established method used to investigate localised brain activation by virtue of the blood oxygen level dependent (BOLD) effect. It often relies on visual presentations using beam projectors, liquid crystal display (LCD) screens, and goggle systems. In this study, we designed an MR compatible, low-cost display unit based on organic light-emitting diodes (OLED) and demonstrated its performance.
View Article and Find Full Text PDFIEEE Trans Med Imaging
December 2018
MRI using nuclei other than protons is of clinical interest due to the important role of these nuclei in cellular processes. Phosphorous-31 (P), for example, plays an important role in energy metabolism. However, measurement of P can be challenging, as the receive signal is weak compared with that of proton (H).
View Article and Find Full Text PDFA double-tuned H/F coil using PIN-diode switches was developed and its performance evaluated. The is a key difference from the previous developments being that this design used a PIN-diode switch in series with an additionally inserted inductor in parallel to one of the capacitors on the loop. The probe was adjusted to F when the reverse bias voltage was applied (PIN-diode OFF), whilst it was switched to H when forward current was flowing (PIN-diode ON).
View Article and Find Full Text PDFIn this study, polycarbonate diol/isosorbide-based antibacterial polyurethane nanofiber fabrics containing Ag nanoparticles were prepared by electrospinning process. Bio-based highly elastic polyurethane was prepared from hexamethylene diisocyanate and isosorbide/polycarbonate diol (8/2) by a simple one-shot bulk polymerization. Ag nanoparticles were formed using simple thermal reduction of silver 2-ethylhexylcarbamate at 120℃.
View Article and Find Full Text PDFPurpose: To propose a new Extended Monopole antenna Array with individual Shields (EMAS) coil that improves the B1 field coverage and uniformity along the z-direction.
Methods: To increase the spatial coverage of Monopole antenna Array (MA) coil, each monopole antenna was shielded and extended in length. Performance of this new coil, which is referred to as EMAS coil, was compared with the original MA coil and an Extended Monopole antenna Array coil with no shield (EMA).
Magn Reson Imaging
November 2014
Purpose: To investigate intracranial microvascular images with transceiver radio-frequency (RF) coils at ultra-high field 7 T magnetic resonance imaging (MRI).
Materials And Methods: We designed several types of RF coils for the study of 7 T magnetic resonance angiography and analyzed quantitatively each coil's performance in terms of the signal-to-noise ratio (SNR) profiles to evaluate the usefulness of RF coils for microvascular imaging applications. We also obtained the microvascular images with different resolutions and parallel imaging technique.
Purpose: To enhance sensitivity and coverage for calf muscle studies, a novel, form-fitted, three-channel phosphorus-31 ((31) P), two-channel proton ((1) H) transceiver coil array for 7 T MR imaging and spectroscopy is presented.
Methods: Electromagnetic simulations employing individually generated voxel models were performed to design a coil array for studying nonpathological muscle metabolism. Static phase combinations of the coil elements' transmit fields were optimized based on homogeneity and efficiency for several voxel models.
Purpose: We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications.
Methods: We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight-channel monopole antenna array and conventional eight-channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity.
Unlabelled: Multimodal nanoparticles have been extensively studied for target-specific imaging and therapy of various diseases, including cancer. In this study, radiolabeled arginine-glycine-aspartic acid (RGD)-functionalized Er(3+)/Yb(3+) co-doped NaGdF(4) upconversion nanophosphors (UCNPs) were synthesized and evaluated as a multimodal PET/MR/optical probe with tumor angiogenesis-specific targeting properties.
Methods: A dimeric cyclic RGDyk ((cRGDyk)(2)) peptide was conjugated to polyacrylic acid-coated NaGdF(4):Yb(3+)/Er(3+) UCNPs along with polyethylene glycol molecules and was consecutively radiolabeled with (124)I.
Coronary artery fistulas have been diagnosed with aortography, coronary angiography, and coronary computed tomography (CT). A large fistula can be occasionally found as a mass lesion on echocardiography but cannot be easily confirmed. Here, we report a new diagnostic approach to coronary artery fistulas using a contrast agent and transthoracic echocardiography.
View Article and Find Full Text PDFBackgrounds: Recent studies have shown that thermal therapy by means of warm waterbaths and sauna has beneficial effects in chronic heart failure. However, a comprehensive investigation of the hemodynamic effects of thermal vasodilation on coronary arteries has not been previously undertaken. In this study, we studied the effect of a warm footbath (WFB) on coronary arteries in patients with coronary artery disease (CAD), as well as any adverse effect.
View Article and Find Full Text PDFImaging of specific intracellular target proteins in living cells has been of great challenge and importance for understanding intracellular events and elucidating various biological phenomena. Highly photoluminescent and water-soluble semiconductor nanocrystal quantum dots (QDs) have been extensively applied to various cellular imaging applications due to the long-term photostability and the tunable narrow emission spectra with broad excitation. Despite the great success of various bioimaging and diagnostic applications, visualization of intracellular targets in live cells still has been of great challenge.
View Article and Find Full Text PDFAn oligonucleotide modified with Ni-nitrilotriacetate (NTA) was successfully synthesized and used for the stoichiometric functionalization of QDs. This synthetic approach allowed for the facile preparation of DNA-QD conjugates with a defined DNA/QD ratio using well-known Ni-histidine coordination chemistry. A FRET based DNA-QD nanoprobe was prepared using this method highlighting the great potential of this synthetic strategy.
View Article and Find Full Text PDFJ Magn Reson Imaging
September 2010
Purpose: To visualize the perforating arteries originating from basilar artery (BA) by using ultra-high resolution 7T MR angiography (MRA) and optimizing MR parameters as well as radio frequency (RF) coils, which may provide important information for neurosurgery and understanding diseases of the pons, but was unable to clearly visualize with conventional MRA techniques.
Materials And Methods: Seven healthy volunteers (five males and two females, age [mean +/- SD] = 28.71 +/- 7.
Synthesis of biologically active antibody conjugated quantum dots (QDs) has been of great importance in cellular imaging and diagnostics. Cetuximab (or Erbitux) is the first monoclonal antibody drug which targets the epidermal growth factor receptor (EGFR) overexpressed in most cancer cells. In the present work, we investigated three different conjugation strategies to obtain the biologically functional QD-cetuximab conjugates for the tumor-specific imaging.
View Article and Find Full Text PDF