Background: The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure.
Methods And Results: All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE.
We describe the role of three-dimensional echocardiography in the assessment of the aortic valve and the aorta. The manuscript is heavily illustrated with figures and movie clips.
View Article and Find Full Text PDFWe describe an adult patient who presented with purulent pericarditis (PP) in whom two-dimensional transthoracic echocardiography demonstrated a marked decrease in the area of the right ventricular (RV) wall together with the overlying fibrin following intrapericardial administration of a fibrinolytic agent. Documentation of this decrease by measurements performed and illustrated on two-dimensional images has not been reported previously in an adult patient with PP, to the best of our knowledge.
View Article and Find Full Text PDFEchocardiography
June 2021
We report the incremental value of live/real-time three-dimensional transthoracic echocardiography (3DTTE) over two-dimensional transthoracic echocardiography (2DTTE) in making a definitive diagnosis of left ventricular endocardial rupture with myocardial dissection and contained apical epicardial rupture in an elderly male patient presenting with acute myocardial infarction. To the best of our knowledge, this has not been described previously.
View Article and Find Full Text PDFWe describe an elderly male patient with two MitraClip devices, one fixed and the other detached, in whom live/real-time three-dimensional echocardiography (3DTEE) provided incremental value and additional information compared to two-dimensional transesophageal echocardiography (2DTEE). 3DTEE offered the ability to comprehensively assess the mitral valve (MV) utilizing full volume and multiplanar reconstruction (MPR) modes. 3DTEE proved useful in assessing the position of the properly attached and the partially detached MitraClip, including assessment of orifice size and degree of mitral regurgitation (MR).
View Article and Find Full Text PDFWe present an adult female in whom two-dimensional transthoracic echocardiography demonstrated encroachment of the thoracic spine on the left atrium (LA) resulting in a very small, compressed LA cavity by a prominent thoracic spine shadow. Computed tomography (CT) scan of the chest showed compression of the LA produced by localized anterior deformation of the thoracic spine which had resulted from blunt injury to her spine following a fall from a swing several years previously.
View Article and Find Full Text PDF