Background: Increased posterior wall acetabular fractures among older adults, require precise treatment to restore stability to the joint, lower the risk of degenerative arthritis, and enhance overall functional recovery. The purpose of this study was to compare the fixation stability and mechanical characteristics of calcaneal buttress plate and conventional reconstruction plate under different loading condition.
Methods: Typical acetabular posterior wall fractures were created on twenty synthetic hemipelvis models.