Objective: To assess tumour factors that reduce primary technical efficacy (PTE) from CT-guided renal cryoablation.
Methods: Patients were taken from the EuRECA registry between December 2014 and November 2020. To focus on tumour factors rather than individual technique, this study was limited to cases using CT and excluded procedures using cone beam, US, MRI, or laparoscopy.
Purpose: Currently, significant medical practice variation exists in thermal ablation (TA) of malignant liver tumors with associated differences in outcomes. The IMaging and Advanced Guidance for workflow optimization in Interventional Oncology (IMAGIO) consortium aims to integrate interventional oncology into the standard clinical pathway for cancer treatment in Europe by 2030, by development of a standardized low-complex-high-precision workflow for TA of malignant liver tumors. This study was conducted at the start of the IMAGIO project with the aim to explore the current state and future role of modern technology in TA of malignant liver tumors.
View Article and Find Full Text PDFPurpose: Treatment of renal cell carcinoma (RCC) in patients with solitary kidneys remains challenging. The purpose of this multicentre cohort study was to explore how renal function is affected by percutaneous image-guided cryoablation in patients with solitary kidneys.
Material And Methods: Data from the European Registry for Renal Cryoablation database were extracted on patients with RCC in solitary kidneys treated with image-guided, percutaneous cryoablation.
Patients presenting with a Stanford type A acute aortic dissection require immediate surgical treatment; however, up to 30% of patients are deemed inoperable. Here we describe a case of a patient with a complicated type A acute aortic dissection presenting with a severe impact of brain malperfusion. In contrast with open surgery, an emergent thoracic endovascular aortic repair was performed with a Gore cTAG 45 × 150 mm graft and an additional chimney graft Advanta V12 7 × 59 mm graft for the brachiocephalic trunk.
View Article and Find Full Text PDFObjectives: To evaluate the use of pre-cryoablation biopsy for small renal masses (SRMs) and the effects of increasing uptake on histological results of treated SRMs.
Methods: From 2015 to 2019, patients with sporadic T1N0M0 SRMs undergoing percutaneous, laparoscopic, or open cryoablation from 14 European institutions within the European Registry for Renal Cryoablation (EuRECA) were included for the retrospective analysis. Univariate and multivariate logistic models were used to evaluate the trends, histological results, and the factors influencing use of pre-cryoablation biopsy.
Background: Complementary to percutaneous intra-abdominal drainage, percutaneous transhepatic biliary drainage (PTBD) might ameliorate healing of pancreatic fistula and biliary leakage after pancreatoduodenectomy by diversion of bile from the site of leakage. This study evaluated technical and clinical outcomes of PTBD for this indication.
Methods: All patients undergoing PTBD for leakage after pancreatoduodenectomy were retrospectively evaluated in two tertiary pancreatic centers (2014-2019).
Objectives: Over 2500 percutaneous transhepatic cholangiography and biliary drainage (PTCD) procedures are yearly performed in the Netherlands. Most interventions are performed for treatment of biliary obstruction following unsuccessful endoscopic biliary cannulation. Our aim was to evaluate complication rates and risk factors for complications in PTCD patients after failed ERCP.
View Article and Find Full Text PDFAim: To determine whether there are differences between idiopathic and hereditary haemorrhagic telangiectasia (HHT) associated pulmonary arteriovenous malformations (PAVMs) (HHT-PAVM) regarding clinical and radiographic characteristics, and the results of embolotherapy.
Materials And Methods: A retrospective analysis was undertaken of all adult and adolescent patients who were diagnosed with a PAVM on chest computed tomography (CT) from January 2006 until August 2019.
Results: In total, 41 patients with idiopathic PAVMs and 194 patients with genetically confirmed HHT and PAVMs were included.
Objective: To investigate the safety profile of percutaneous cryoablation of renal tumours < 7 cm, utilising data extracted from an international multicentre registry.
Materials And Methods: A retrospective review of all immediate and delayed complications from a multicentre database was performed and was categorised according to the Clavien-Dindo classification. Statistical analysis was performed for both overall complications (all Clavien-Dindo) and major complications (Clavien-Dindo 3 to 5).
Background: Endovascular iliac artery interventions rely on the use of two-dimensional digital subtraction angiographies with an iodinated contrast agent and ionizing radiation. The amount of iodinated contrast agent should be limited because of its potentially nephrotoxic effects. Three-dimensional (3D) image fusion requires registration of a preprocedural magnetic resonance angiogram (MRA) or computed tomography (CT) angiogram to a perprocedurally acquired cone-beam CT or two fluoroscopic orthogonal projections.
View Article and Find Full Text PDFRenal cryoablation is becoming an established treatment option for small renal masses. It allows preservation of renal function without compromising cancer control. The technique has evolved considerably since it was first reported using liquid nitrogen over 20 years ago.
View Article and Find Full Text PDFBackground: Cryoablation has emerged as an alternative to the more invasive partial nephrectomy for small renal masses. The approach can be carried out by two techniques, either laparoscopic cryoablation (LCA) or percutaneous cryoablation, (PCA) with CT guidance. We aimed to compare between the two procedures.
View Article and Find Full Text PDFIntroduction: The effect of the insertion of guidewires and catheters on fusion accuracy of the three-dimensional (3D) image fusion technique during iliac percutaneous transluminal angioplasty (PTA) procedures has not yet been investigated.
Evidence Acquisition: Technical validation of the 3D fusion technique was evaluated in 11 patients with common and/or external iliac artery lesions. A preprocedural contrast-enhanced magnetic resonance angiogram (CE-MRA) was segmented and manually registered to a cone-beam computed tomography image created at the beginning of the procedure for each patient.
Purpose: To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time.
Methods: Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time.
Cardiovasc Intervent Radiol
September 2016
Purpose: To determine whether equivalent-quality images can be obtained from digital subtraction angiography (DSA) of the iliac artery after implementation of a novel imaging technology that reduces patient and scatter x-ray dose.
Materials And Methods: Imaging using two randomly ordered DSA runs was performed in 51 adults scheduled for iliac artery angiography or intervention or both. One DSA run used standard acquisition chain and image processing algorithms (referred to as " reference DSA"), and the other DSA run used dose-reduction and real-time advanced image noise reduction technology (referred to as "study DSA").
J Cardiovasc Surg (Torino)
October 2014
Endovascular aneurysm management (EVAR) is hampered by persistent arterial blood flow in the aneurysm sac after treatment, known as endoleak (EL). Type II EL consist of blood flow from one or more aortic branch vessels; they only require treatment when the aneurysm sac fails to shrink. Post-EVAR follow up is mostly done with contrast enhanced computed tomography.
View Article and Find Full Text PDFBackground: Transcatheter embolisation is widely used to close pulmonary arteriovenous malformations (PAVMs) in patients with hereditary haemorrhagic telangiectasia (HHT). Data on the direct cardiovascular haemodynamic changes induced by this treatment are scarce.
Objectives: We investigated the direct haemodynamic effects of transcatheter embolisation of PAVMs, using non-invasive finger pressure measurements.
Objective: To determine the accuracy of cone beam CT (CBCT) guidance and CT guidance in reaching small targets in relation to needle path complexity in a phantom.
Methods: CBCT guidance combines three-dimensional CBCT imaging with fluoroscopy overlay and needle planning software to provide real-time needle guidance. The accuracy of needle positioning, quantified as deviation from a target, was assessed for inplane, angulated and double angulated needle paths.
Malignant mesothelioma is primarily located in the pleura. Progression usually involves adjacent tissue invasion. Both lymphatic and haematogenous spreads are possible, but rare.
View Article and Find Full Text PDFObjective: To investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.
Materials And Methods: On 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy.
Objective: To determine whether 3D cone-beam computed tomography (CBCT) guidance allows safe and accurate biopsy of suspected small renal masses (SRM), especially in hard-to-reach anatomical locations.
Materials And Methods: CBCT guidance was used to perform 41 stereotactic biopsy procedures of lesions that were inaccessible for ultrasound guidance or CT guidance. In CBCT guidance, a 3D-volume data set is acquired by rotating a C-arm flat-panel detector angiosystem around the patient.
The Angio-Seal (St. Jude Medical, Minnetonka, Minn) is a frequently used percutaneous femoral artery closure device to obtain hemostasis after arterial catheterization. Separation and migration of the device, leading to distal embolization and limb-threatening ischemia necessitating emergency surgery, is reported but extremely rare.
View Article and Find Full Text PDFPurpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques.
Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis.