Publications by authors named "Streel B"

Nowadays, many efforts are devoted to improve analytical methods regarding efficiency, analysis time and greenness. In this context, Supercritical Fluid Chromatography (SFC) is often regarded as a good alternative over Normal Phase Liquid Chromatography (NPLC). Indeed, modern SFC separations are fast, efficient with suitable quantitative performances.

View Article and Find Full Text PDF

In the uprising context of green analytical chemistry, Supercritical Fluid Chromatography (SFC) is often suggested as an alternative to Normal Phase Liquid Chromatography. Indeed, SFC provides fast, efficient and green separations. In this report, the quantitative performances of SFC were challenged on a real-life case study: the Quality Control (QC) of vitamin D3.

View Article and Find Full Text PDF

Fenofibrate, a BCS class II compound, has a low bioavailability especially when taken orally on an empty stomach. The challenge to find a new formulation for providing bioavailability, independent of food, is still ongoing. If the development of a suitable oral delivery formulation of BCS class II compounds is a frequent and great challenge to formulation scientists, the in vitro evaluation of these new formulations is also a great challenge.

View Article and Find Full Text PDF

Recurrent Pseudomonas aeruginosa infections involving biofilm formation are frequent in cystic fibrosis, aggravating the respiratory distress. Co-administration of clarithromycin and classical tobramycin could improve the health status of patients. Antibiotic toxicity was assessed on epithelial (CFBE41o(-)) and macrophagic (THP-1) cell lines.

View Article and Find Full Text PDF

Purpose: The therapeutic equivalence of multiple registered fenofibrate formulations, several of which are suprabioavailable and therefore marketed at lower dosage strengths than their reference products, is based on the results of bioequivalence studies. Most of these formulations show a higher bioavailability when taken with a high-fat meal. The relative bioavailability of two of these formulations, the 200 mg Lidose hard capsules and the 145 mg nanoparticle tablets, was assessed when taken with a high-fat meal.

View Article and Find Full Text PDF

The aim of this study was to develop a formulation containing fenofibrate and Gelucire(®) 50/13 (Gattefossé, France) in order to improve the oral bioavailability of the drug. Particles from gas saturated solutions (PGSS) process was chosen for investigation as a manufacturing process for producing a solid dispersion. The PGSS process was optimized according to the in vitro drug dissolution profile obtained using a biphasic dissolution test.

View Article and Find Full Text PDF

Newly developed drugs often have poor bioavailability due to their poor water solubility (BCS class 2 drugs). It is therefore necessary to develop new strategies to enhance their solubility and their activity, among which, Self-Emulsifying Drug Delivery System (SEDDS). The efficacy of the drugs contained in these preparations is mainly affected by the solid state and the particle size of the active pharmaceutical ingredient (API).

View Article and Find Full Text PDF

During galenic formulation development, homogeneity of distribution is a critical parameter to check since it may influence activity and safety of the drug. Raman hyperspectral imaging is a technique of choice for assessing the distributional homogeneity of compounds of interest. Indeed, the combination of both spectroscopic and spatial information provides a detailed knowledge of chemical composition and component distribution.

View Article and Find Full Text PDF

The present study focuses on the implementation of an in-line quantitative near infrared (NIR) spectroscopic method for determining the active content of pharmaceutical pellets. The first aim was to non-invasively interface a dispersive NIR spectrometer with four realistic particle streams existing in the pellets manufacturing environment. Regardless of the particle stream characteristics investigated, NIR together with Principal Component Analysis (PCA) was able to classify the samples according to their active content.

View Article and Find Full Text PDF

A robust near infrared (NIR) method able to quantify the active content of pilot non-coated pharmaceutical pellets was developed. A protocol of calibration was followed, involving 2 operators, independent pilot batches of non-coated pharmaceutical pellets and two different NIR acquisition temperatures. Prediction models based on Partial Least Squares (PLS) regression were then carried out.

View Article and Find Full Text PDF

Analytical method validation is a mandatory step at the end of the development in all analytical laboratories. It is a highly regulated step of the life cycle of a quantitative analytical method. However, even if some documents have been published there is a lack of clear guidance for the methodology to follow to adequately decide when a method can be considered as valid.

View Article and Find Full Text PDF

The aim of the present study was to develop and validate a near infrared method able to accurately determine a moisture content of pharmaceutical pellets ranging from 1% to 8% in order to check their moisture content conformity. A calibration and validation set were designed for the conception and evaluation of the method adequacy. An experimental protocol was then followed, involving two operators, independent production campaign batches and different temperatures for data acquisition.

View Article and Find Full Text PDF

A robust, sensitive and selective method to quantify budesonide epimers in human plasma using solid-phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. The drug was first isolated from the biological matrix by automated solid-phase extraction (SPE) on disposable extraction cartridges (C-2). The methanolic eluate was then collected and evaporated to dryness.

View Article and Find Full Text PDF

In this study, a sensitive and selective method based on liquid chromatography combined with diode array and tandem mass spectrometry detection (LC-DAD-MS/MS) was developed for the simultaneous quantitative determination of fenofibric acid, pravastatin and its main metabolites in human plasma. In this method, an automated solid-phase extraction (SPE) on disposable extraction cartridges (DECs) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-DAD-MS/MS system. On-line LC-DAD-MS/MS system using an atmospheric pressure ionization (TurboIonSpray) was then developed for the simultaneous determination of pravastatin, 3-hydroxy isomeric metabolite (3-OH metab), pravalactone and fenofibric acid.

View Article and Find Full Text PDF

It is recognized that the purpose of validation of analytical methods is to demonstrate that the method is suited for its intended purpose. Validation is not only required by regulatory authorities, but is also a decisive phase before the routine use of the method. For a quantitative analytical method the objective is to quantify the target analytes with a known and suitable accuracy.

View Article and Find Full Text PDF

Two new statistical approaches to assess the validity of the transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid were investigated and compared to the conventional approaches generally used in this domain. These new approaches, namely the Tolerance Interval and the Risk approaches, are based on the simultaneous evaluation of the systematic (or trueness) and random (or precision) errors of the transfer into a single criterion called total error (or accuracy). The results of the transfer showed that only the total error based approaches fulfilled the objective of an analytical method transfer, i.

View Article and Find Full Text PDF

A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water.

View Article and Find Full Text PDF

A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.

View Article and Find Full Text PDF

Aims: To compare the pharmacokinetic profile of a new modified release formulation of tramadol (Tramadol LP 200 mg, SMB Technology, Marche-en-Famenne, Belgium) with that of an immediate release capsule (Topalgic) 50 mg, Grünenthal, Aachen, Germany) after single and multiple dosing and to assess the potential effect of food on its relative bioavailability.

Methods: The first study had an open, single-dose, three-treatment, three-period, six-sequence, randomised, crossover design with at least a five-day wash-out. The second study had an open, steady-state, two-treatment, two-period, two-sequence, randomised crossover design with at least a seven-day wash-out.

View Article and Find Full Text PDF

A highly sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of buprenorphine and its active metabolite norbuprenorphine in human plasma. Automated solid phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample (1.

View Article and Find Full Text PDF

In the pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipment and areas. The cleaning procedures must be validated and the methods to determine trace amounts of drugs have therefore to be considered with special attention. A high performance liquid chromatographic method for the determination of amlodipine residues in swab samples was developed and validated in order to control a cleaning procedure.

View Article and Find Full Text PDF

A sensitive method for the separation and determination of amlodipine enantiomers in plasma has been developed based on solid-phase extraction (SPE) with disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE technique is used to isolate the drug from the biological matrix and to prepare a cleaner sample before injection and analysis by HPLC coupled to mass spectrometry. The DEC is filled with ethyl silica (50 mg) and is first conditioned with a 2.

View Article and Find Full Text PDF

Dry powder inhalers (DPIs) are used to deliver asthma drugs to patients, but lung deposition may depend upon the degree of inspiratory effort. The pulmonary deposition of the glucocorticosteroid budesonide (SMB-Galephar) has been assessed in 12 asthmatic patients when delivered by the Monodose inhaler (Miat, Milan, Italy); the Pulmicort Turbuhaler DPI (AstraZeneca, Lund, Sweden) was used as a comparator product. Patients inhaled from each device with maximal or sub-maximal inspiratory effort: Monodose inhaler 90 vs 45 l/min; Turbuhaler DPI 60 vs 30 l/min.

View Article and Find Full Text PDF

Bioequivalence of a newly developed semi-solid formulation (Lidose) of fenofibrate (CAS 49562-28-9), and a reference, micronized formulation of fenofibrate was investigated in two randomised, open-label clinical studies with a crossover design. Both studies involved two distinct groups of 24 healthy volunteers. Doses of 67 mg and 200 mg, respectively, were used in study 1 and study 2.

View Article and Find Full Text PDF