Aims: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation.

View Article and Find Full Text PDF
Article Synopsis
  • Conduction system pacing (CSP) is shown to potentially outperform traditional right ventricular pacing methods, prompting exploration of a new catheter for easier implantation.
  • The BIO|MASTER.Selectra 3D study reported a 93.6% success rate for achieving CSP in 147 out of 157 patients, with no serious complications within a week post-implantation.
  • Results indicate that patient outcomes can improve with the Selectra 3D catheter, which allows flexibility between His bundle pacing (HBP) and left bundle branch area pacing (LBBAP), yielding nearly 99% success in procedures where both methods were considered.
View Article and Find Full Text PDF

Background: Catheter ablation is an established therapy for paroxysmal atrial fibrillation (PAF). The TactiFlex Ablation Catheter, Sensor Enabled (TactiFlex SE) is a next-generation radiofrequency ablation catheter incorporating fiber optics-based contact force-sensing technology with a flexible, laser-cut tip.

Objective: The study sought to evaluate the safety and effectiveness of the TactiFlex SE ablation catheter for treatment of drug-refractory PAF.

View Article and Find Full Text PDF

Atrial fibrillation is now a pandemic in our ageing community. Although James L. Cox devised a surgical procedure with near-universal curative success in 1987, catheter-based interventions have flourished.

View Article and Find Full Text PDF

Junctional ectopic tachycardia (JET) is a tachyarrhythmia arising from the atrioventricular node and His bundle area. Enhanced normal automaticity has been postulated as the mechanism of JET in the majority of patients. It is more common in children and can be seen as congenital or in postoperative settings.

View Article and Find Full Text PDF

Purpose: Since the introduction of the Biotronik Linox S/SD leads in 2006, there have been multiple reports of premature lead failure. The purpose of this study was to investigate the longevity of the Linox S/SD leads and to identify the possible predictors of lead failure in a single tertiary implant center.

Methods: We retrospectively reviewed patients who underwent implantation of Linox S/SD leads or Sorin Vigila 1CR/2CR leads (the same Linox S/SD leads marketed by Sorin) at our center.

View Article and Find Full Text PDF

Pacemakers can be directly involved in initiating or sustaining different forms of arrhythmia. These can cause symptoms such as dyspnea, palpitations, and decompensated heart failure. Early detection of these arrhythmias and optimal pacemaker programming is pivotal.

View Article and Find Full Text PDF

Here, we discuss the case of a man with a history of ischemic cardiomyopathy and cardiac resynchronization therapy defibrillator implantation, who presented to emergency department with decompensated heart failure due to the loss of resynchronization therapy. The reason for the malfunction was left ventricle upper rate interval lock-in due to inappropriate programming of the device.

View Article and Find Full Text PDF

We discuss a 46-year-old man with history of hypertension and inferior wall myocardial infarction and mild left ventricular dysfunction who presented with aborted sudden cardiac death due to episodes of ventricular tachyarrhythmia detected by a Reveal-LINQ which had been implanted one year prior to presentation.