Publications by authors named "Steven Wolff"

In the ACC/AHA guidelines, the presence of symptoms plays a central role in determining timing surgery in primary mitral regurgitation (MR). Studies have shown a disconnect between the severity of MR and symptoms. The purpose of this study is to assess risk factors for symptoms in patients with chronic primary MR.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to compare the American Society of Echocardiography (ASE) algorithm for assessing mitral regurgitation (MR) to cardiac magnetic resonance (CMR) and left ventricular (LV) remodeling following mitral intervention.

Background: The ASE recommends integrating multiple echocardiographic parameters for assessing MR. The ASE guidelines include an algorithm that weighs the parameters and highlights those considered indicative of definitely mild or definitely severe MR.

View Article and Find Full Text PDF

Background: Echocardiography guidelines note that a flail leaflet is a specific criterion for severe mitral regurgitation (MR) and that regurgitant severity is underestimated in wall-impinging jets (Coandă effect). Both findings are often considered to be pathognomonic of severe MR.

Objectives: In this study, the authors sought to determine the association of flail leaflet and Coandă effect with MR severity quantified by means of cardiac magnetic resonance (CMR).

View Article and Find Full Text PDF

Patients with valvular heart disease-related heart failure are unable to pump enough blood to meet the body's needs. Magnetic resonance imaging (MRI) can play an important role by identifying these patients and distinguishing them from patients whose valvular disease is not the cause of their heart failure. Heart failure is a major public health problem, with a prevalence of 5.

View Article and Find Full Text PDF

MRI studies have shown a tight correlation between mitral regurgitant volume and left ventricular end-diastolic volume (LV EDV) in patients with primary chronic mitral regurgitation (MR). They have also shown a tight correlation between regurgitant volume and the decrease in LVEDV following mitral valve surgery. The purpose of this study is to validate an empiric calculation that can be used preoperatively to predict the amount of left ventricular remodeling following mitral valve correction.

View Article and Find Full Text PDF

Objectives: This study sought to assess the impact of systolic variation of mitral regurgitation (MR) has on discordance between echocardiography and magnetic resonance imaging (MRI).

Background: Studies have shown discordance between echocardiography and MRI when assessing the severity of MR. Contributing factors to this discordance may include the systolic variation of MR and the use of the color Doppler jet at a single point in time as the basis of many echocardiographic methods.

View Article and Find Full Text PDF

Background: The American Society of Echocardiography (ASE) guidelines suggest the use of several echocardiographic methods to assess mitral regurgitation severity using an integrated approach, without guidance as to the weighting of each parameter. The purpose of this multicenter prospective study was to evaluate the recommended echocardiographic parameters against a reference modality and develop and validate a weighting for each echocardiographic measure of mitral regurgitation severity.

Methods: This study included 112 patients who underwent evaluation with echocardiography and magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Accurate quantification of regurgitant volume is a central component to the management of mitral regurgitation. Cardiac magnetic resonance imaging (CMR) accurately quantifies mitral regurgitation as the difference between left ventricular stroke volume and forward stroke volume using steady state free precession and phase contrast imaging. The CMR measurement of mitral regurgitant volume is reproducible and can quantify mitral regurgitation in patients without regard to regurgitant jet morphology, such as patients with multiple and eccentric jets.

View Article and Find Full Text PDF

Background: The presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverter-defibrillator (ICD) that was "non-MRI-conditional" (i.

View Article and Find Full Text PDF

Purpose: To examine imaging utilization in a matched cohort of patients with and without implantable cardioverter defibrillators (ICD) and to project magnetic resonance imaging (MRI) utilization over a 10-year period.

Materials And Methods: The Truven Health MarketScan Commercial claims and Medicare Supplemental health insurance claims data were used to identify patients with continuous health plan enrollment in 2009-2012. Patients with ICDs were identified using ICD-9 and CPT codes, and matched to patients with the same demographic and comorbidity profile, but no record of device implantation.

View Article and Find Full Text PDF

Background: The decision to undergo mitral valve surgery is often made on the basis of echocardiographic criteria and clinical assessment. Recent changes in treatment guidelines recommending surgery in asymptomatic patients make the accurate assessment of mitral regurgitation (MR) severity even more important.

Objectives: The purpose of this study was to compare echocardiography and magnetic resonance imaging (MRI) in the assessment of MR severity using the degree of left ventricular (LV) remodeling after surgery as the reference standard.

View Article and Find Full Text PDF

The relation between left anterior descending coronary artery (LAD) anatomic features and clinical outcomes in patients with anterior ST-segment elevation myocardial infarction has not been fully investigated. The Intracoronary Abciximab and Aspiration Thrombectomy in Patients With Large Anterior Myocardial Infarction (INFUSE-AMI) trial randomized 452 patients with anterior ST-segment elevation myocardial infarctions who underwent mechanical revascularization to intralesional abciximab versus no abciximab and to manual thrombus aspiration versus no aspiration. The primary end point was infarct size (percentage left ventricular mass) on contrast magnetic resonance imaging at 30 days.

View Article and Find Full Text PDF

Background: Magnetic resonance imaging (MRI) can be safely performed in patients with magnetic resonance (MR)-conditional pacemaker systems but remains relatively contraindicated with non-MR-conditional pacemaker systems.

Objective: The purpose of this study was to evaluate the safety of MRI without positioning restrictions in patients with an MR-conditional pacemaker and currently a non-MR-conditional Medtronic CapSureFix Novus 5076 lead(s).

Methods: The study randomized 266 patients in a 2:1 ratio to the MRI group (177 patients) or to the control group (89 patients).

View Article and Find Full Text PDF

Aim: Cardiovascular magnetic resonance (CMR) has been increasingly used as an alternative method to evaluate the severity of aortic stenosis. The aim of our study was to evaluate whether the indirect measurement of the aortic gradient (Calc-PG), derived from Gorlin's formula, is a reproducible parameter for gradient assessment. Then, we evaluated if this parameter is correlated with left ventricular hypertrophy, considered as a marker of severity of aortic stenosis, better than phase-contrast sequences-derived pressure gradient (PC-PG) and aortic valve area.

View Article and Find Full Text PDF

Introduction: Many challenges to clinical trial accrual exist, resulting in studies with inadequate enrollment and potentially delaying answers to important scientific and clinical questions.

Methods: The National Cancer Institute (NCI) and the American Society of Clinical Oncology (ASCO) cosponsored the Cancer Trial Accrual Symposium: Science and Solutions on April 29-30, 2010 to examine the state of accrual science related to patient/community, physician/provider, and site/organizational influences, and identify new interventions to facilitate clinical trial enrollment. The symposium featured breakout sessions, plenary sessions, and a poster session including 100 abstracts.

View Article and Find Full Text PDF

Background: The systolic variation of mitral regurgitation (MR) is a pitfall in its quantification. Current recommendations advocate using quantitative echocardiographic techniques that account for this systolic variation. While prior studies have qualitatively described patterns of systolic variation no study has quantified this variation.

View Article and Find Full Text PDF

Background: Whether intralesional abciximab administration and thrombus aspiration confer clinical benefits to patients undergoing primary percutaneous coronary intervention for ST-segment-elevation myocardial infarction is controversial.

Methods And Results: A total of 452 patients with ST-segment-elevation myocardial infarction caused by proximal or mid left anterior descending artery occlusion undergoing primary percutaneous coronary intervention with bivalirudin anticoagulation were randomized in a 2×2 factorial design to bolus abciximab delivered locally at the infarct lesion site versus no abciximab and to manual thrombus aspiration versus no aspiration. Treatment with intralesional abciximab, thrombus aspiration, or both therapies compared with no active therapy before stent implantation resulted in lower 1-year rates of death (4.

View Article and Find Full Text PDF

Ventricular dyssynchrony significantly impairs cardiac performance. However, the independent role of interventricular dyssynchrony (interVD) and intraventricular dyssynchrony (intraVD) in the development of abnormalities of systolic and diastolic performance is unclear. Cardiac magnetic resonance imaging was performed in 39 patients with left bundle branch block and 13 healthy patients.

View Article and Find Full Text PDF