Background: Lumbar interbody fusion (IF) is a common procedure to fuse the anterior spine. However, a lack of consensus on image-based fusion assessment limits the validity and comparison of IF studies. This systematic review aims to (1) report on IF assessment strategies and definitions and (2) summarize available literature on the diagnostic reliability and accuracy of these assessments.
View Article and Find Full Text PDFObjective: To determine the comparability among 10 radiographic anteversion methods for acetabular cup orientation in total hip arthroplasty (THA) found in the literature and the "gold" standard of assessing the anteversion with CT.
Methods: This is a retrospective study that blindly compares 10 different conventional radiographic anteversion measurements with the "gold" standard, the measurement of anteversion on the transverse plane of the 3-D images made with CT. The patient archiving and communications system (PACS) was systematically searched for subjects that had undergone a CT angiogram of the abdomen and lower extremities, including the pelvis, had at least one THA in situ and had undergone anterior-posterior (AP) and cross-lateral pelvic radiography between January 2013 and August 2016 in the Diakonessenhuis Hospital Utrecht/Zeist, a non-academic institution.
Background: This study aims to analyze the incidence and outcomes of bicycle-related injuries in hospitalized patients in The Netherlands.
Methods: Bicycle accidents resulting in hospitalization in a level-I trauma center in The Netherlands between 2007 and 2017 were retrospectively identified. We subcategorized data of patients involved in a regular bicycle, race bike, off-road bike or e-bike accident.
J Biomed Mater Res B Appl Biomater
April 2019
Polyetheretherketone (PEEK) is commonly used as a spinal spacer for intervertebral fusion surgery. Unfortunately, PEEK is bioinert and does not effectively osseointegrate into living bone. In contrast, comparable spacers made of silicon nitride (Si N ) possess a surface nanostructure and chemistry that encourage appositional bone healing.
View Article and Find Full Text PDFObjectives: Degenerative lumbosacral stenosis (DLSS) is characterized by intervertebral disc degeneration and causes lower back pain in dogs. Temporary distraction in rabbit models with induced intervertebral disc degeneration showed signs of intervertebral disc repair. In the present study, we assessed safety and efficacy of temporary segmental distraction in a dog with clinical signs of DLSS.
View Article and Find Full Text PDFIntroduction:: Dislocation is 1 of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system.
View Article and Find Full Text PDFLittle is known about the clinical application of highly cross-linked polyethylene (HXLPE) blended with vitamin E. This study evaluates an uncemented iso-elastic monoblock cup with vitamin E blended HXLPE. 112 patients were followed up for 2years.
View Article and Find Full Text PDFPurpose: We evaluated the 5-year survival of the uncemented Optan anatomically adapted femoral stem, with revision for aseptic loosening as the endpoint.
Methods: Between January 2004 and March 2007, 432 total hip arthroplasties (THAs) were performed in 432 patients. After follow-up for a mean time of 5 years, the patients were evaluated using the WOMAC questionnaire and plain radiography.
J Biomed Mater Res B Appl Biomater
November 2014
The mal-positioning of total hip arthroplasty components can result in edge loading conditions. Purpose of this study was to determine if the wear rate of ceramic-on-ceramic and metal-on-polyethylene increases under edge loading conditions. The literature was reviewed to determine which of the commonly used hip bearings is the most forgiving to implant mal-orientation.
View Article and Find Full Text PDFBackground: Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible.
View Article and Find Full Text PDFBackground Context: Polyetheretherketone (PEEK) cages have been widely used during the past decade in patients with degenerative disorders of the cervical spine. Their radiolucency and low elastic modulus make them attractive attributes for spinal fusion compared with titanium and bone graft. Still, limitations are seen such as pseudoarthrosis, subsidence, and migration of the cages.
View Article and Find Full Text PDFBackground: Monoblock acetabular components used in uncemented total hip arthroplasty (THA) have certain mechanical characteristics that potentially reduce acetabular osteolysis and polyethylene wear. However, the degree to which they achieve this goal is not well documented.
Questions/purposes: The purpose of this study was to use a systematic review of controlled trials to test the hypothesis that monoblock cups have superior (1) polyethylene wear rate; (2) frequency of cup migration; (3) frequency of acetabular osteolysis; and (4) frequency of aseptic loosening compared with modular components used in uncemented THA.
The Morscher monoblock cup is designed for optimal osteointegration and holds the potential for excellent long-term survival. The Metasul-on-Metasul bearing was introduced to eliminate wear-induced periprosthetic osteolysis. This study reviews 137 Morscher cups with a 28-mm Metasul-on-Metasul bearing used in primary THA at 5.
View Article and Find Full Text PDFTissue Eng Part B Rev
April 2010
The use of fluorochromes in bone research is a widely accepted technique that dates back to the 1950s. Several pioneers, such as Harold Frost, have thoroughly investigated the potential of fluorochrome use for the study on bone formation and bone remodeling dynamics. Since the development of bone tissue engineering, a renewed interest in the benefits of fluorochrome use was perceived.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of implant location on bone formation in goats using autologous bone marrow-derived stromal cells in porous calcium phosphate scaffolds. Intramuscular locations were compared to posterolateral spine fusion locations in eight goats. As scaffolds, we used biphasic calcium phosphate porous blocks of 5 x 5 x 5 mm.
View Article and Find Full Text PDFMost current methods for cell monitoring on 3D porous scaffolds involve end-stage investigation of scaffolds. Repeated measurements on scaffolds, without disturbing cell vitality and proliferation, are needed to relate in vitro to in vivo data. Alamar Blue was used for this purpose.
View Article and Find Full Text PDF