Background: The Optilume benign prostatic hyperplasia (BPH) catheter system is a novel minimally invasive paclitaxel-coated dilation system that has demonstrated substantial and durable results in urinary flow and symptoms.
Aim: We now assess the impact of Optilume BPH procedure on sexual function.
Methods: Prior published results have described the methods of data collection during the PINNACLE study, which demonstrated durable improvement in urinary symptoms.
Benign prostatic hyperplasia is a prevalent condition leading to male lower urinary tract symptoms (mLUTS), particularly in aging populations. Current management strategies-spanning watchful waiting, pharmaceutical therapy, and surgical interventions such as transurethral resection of the prostate-face significant limitations, including side effects, low adherence, and patient hesitancy toward invasive treatments. First-line interventional therapy (FIT) emerges as a novel paradigm bridging the gap between medications and surgery.
View Article and Find Full Text PDFObjective: This study aims to compare the long-term outcomes of Aquablation for small-to-moderate (30-80 cm) prostates with the outcomes for large (80-150 cm) prostates at 5-year follow up.
Methods: The Waterjet Ablation Therapy for Endoscopic Resection of Prostate Tissue (WATER; NCT02505919) is a prospective, double-blind, international clinical trial encompassing 116 patients, examining Aquablation versus transurethral resection of the prostate (TURP) for LUTS/BPH in prostates sized between 30 and 80 cm. In parallel, WATER II (W-II; NCT03123250), a prospective, multicentre, single-arm international clinical trial, explores Aquablation outcomes in prostates ranging from 80 to 150 cm.
Objective: To report real-world experience of 4-year safety and efficacy outcomes of Aquablation procedure for the treatment of men with symptomatic benign prostatic hyperplasia (BPH).
Methods: This is a prospective single-center, observational study evaluating the outcomes of robotic-assisted Aquablation therapy for moderate-to-severe BPH between December 2019 and December 2023. Patient-level data included age, prostate volume, IPSS score, peak urinary flow rate (Qmax), post-void residual (PVR) were evaluated at 3 M, 6 M, and Years 1-4.
Introduction: The purpose of this study was to gather initial safety and efficacy data with the Optilume BPH Catheter System for the treatment of lower urinary tract symptoms (LUTS) secondary to benign prostatic hyperplasia (BPH).
Methods: A total of 80 men with moderate-to-severe LUTS secondary to BPH were enrolled and treated with the Optilume BPH Catheter System. Symptoms were evaluated using the International Prostate Symptom Score (IPSS) and Benign Prostatic Hyperplasia-Impact Index (BPH-II).
Key Points: Prior efficacy study—established that more frequent dialysis achieved better outcomes than CONVENTIONAL dialysis in outpatients. We undertook an effectiveness observational on-site nursing home study (=195) comparing on-site more frequent dialysis with CONVENTIONAL dialysis. More frequent dialysis patients, despite being sicker at baseline, returned home faster than CONVENTIONALLY dialyzed patients without worsened death or hospitalization.
View Article and Find Full Text PDFBackground: Patient outcomes were assessed 2 years after treatment with the Optilume BPH Catheter System, a minimally invasive surgical therapy for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH).
Methods: One-hundred forty-eight adult males with symptomatic BPH were enrolled and randomized in a 2:1 fashion to Optilume BPH or Sham (100 Optilume BPH; 48 Sham). Long-term measures include International Prostate Symptom Score (IPSS), peak urinary flow rate (Qmax), Post-Void Residual Urine (PVR), quality of life measures and sexual function.
Objective: To examine how representative 24-hour data collection is of the overall patient experience utilizing a home uroflow device in men with benign prostatic hyperplasia (BPH).
Materials And Methods: Home uroflow data were collected with the iO Urology CarePath device from men at a single urology clinic and retrospectively analyzed. Void characteristics were summarized for data collected over 24 hours compared to data collected over several days or weeks with the device (overall study excludes the 24-hour data).
Prostate Cancer Prostatic Dis
April 2024
Background: The surgical landscape for Lower Urinary Tract Symptoms (LUTS) and Benign Prostatic Hyperplasia (BPH) has evolved with the introduction of Minimally Invasive Surgical Therapies (MISTs), recognizing the impact of sexual function on patients' well-being, and prioritizing ejaculation-sparing approaches.
Methods: This systematic review explored ejaculation sparing after classic endoscopic procedures and MISTs (iTind, Rezūm, Urolift, Aquablation, and TPLA) and a literature search yielded 41 studies.
Results: While all procedures demonstrated efficacy in improving LUTS/BPH symptoms (IPSS, QoL, Qmax), a subset of studies evaluated ejaculatory function.
Prostate Cancer Prostatic Dis
June 2024
Introduction: To report the 5-year efficacy and safety of Aquablation compared with transurethral resection of the prostate for the management of lower urinary tract symptoms secondary to benign prostatic hyperplasia in men with prostate volumes 50-80 mL.
Materials And Methods: In a large double-blinded, multicenter, and prospective randomized controlled trial, 96 randomized men with 50-80 mL prostates who underwent Aquablation or transurethral prostate resection were prospectively identified for subgroup analysis. Follow up was performed for up to 5 years.