The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed.

View Article and Find Full Text PDF

Time-of-flight mass spectrometry (TOFMS) is one of the simplest and most powerful approaches for mass spectrometry. Realization of the advantages inherent in TOFMS requires innovation in the theory and practice of the technique. Instrumental developments, in turn, create new capabilities that enable applications in chemical measurement.

View Article and Find Full Text PDF

Enzymatic digestion of proteins is a critical step in bottom-up and middle-down proteomics. Here, we demonstrate a method for decreasing the time required for proteolytic digestion of proteins from multiple hours to minutes by using an in-line microstrip cavity for programmed microwave heating. When a nanospray emitter tip, containing a digestion sample, is exposed to a region of highly focused microwave field, the rate of proteolytic digestion is enhanced and the time required for digestion greatly decreased.

View Article and Find Full Text PDF

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime.

View Article and Find Full Text PDF

Glow discharges have long been used for depth profiling and bulk analysis of solid samples. In addition, over the past decade, several methods of obtaining lateral surface elemental distributions have been introduced, each with its own strengths and weaknesses. Challenges for each of these techniques are acceptable optical throughput and added instrumental complexity.

View Article and Find Full Text PDF

The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level.

View Article and Find Full Text PDF

Our research group earlier used dispersion that occurs during flow injection to detect and reduce matrix interference in inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS). In the absence of a matrix interference, the ratio of signals from any two sample constituents should remain constant, independent of the dilution, over the course of a flow-injection transient. However, when an interferent is present, the signal ratio from different analytes will change with dilution, owing to the difference in severity of the interference on specific analytes.

View Article and Find Full Text PDF

Distance-of-flight mass spectrometry (DOFMS) separates ions of different mass-to-charge (m/z) by the distance they travel in a given time after acceleration. Like time-of-flight mass spectrometry (TOFMS), separation and mass assignment are based on ion velocity. However, DOFMS is not a variant of TOFMS; different methods of ion focusing and detection are used.

View Article and Find Full Text PDF

A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS.

View Article and Find Full Text PDF

Distance-of-flight mass spectrometry (DOFMS) is demonstrated for the first time with a commercially available ion detector-the IonCCD camera. Because DOFMS is a velocity-based MS technique that provides spatially dispersive, simultaneous mass spectrometry, a position-sensitive ion detector is needed for mass-spectral collection. The IonCCD camera is a 5.

View Article and Find Full Text PDF

Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single cells and live first instar larvae.

View Article and Find Full Text PDF

Ambient desorption/ionization (ADI) sources coupled to mass spectrometry (MS) offer outstanding analytical features: direct analysis of real samples without sample pretreatment, combined with the selectivity and sensitivity of MS. Since ADI sources typically work in the open atmosphere, ambient conditions can affect the desorption and ionization processes. Here, the effects of internal source parameters and ambient humidity on the ionization processes of the flowing atmospheric pressure afterglow (FAPA) source are investigated.

View Article and Find Full Text PDF

In the last several years, illicit electronic components have been discovered in the inventories of several distributors and even installed in commercial and military products. Illicit or counterfeit electronic components include a broad category of devices that can range from the correct unit with a more recent date code to lower-specification or non-working systems with altered names, manufacturers and date codes. Current methodologies for identification of counterfeit electronics rely on visual microscopy by expert users and, while effective, are very time-consuming.

View Article and Find Full Text PDF

In this study, we demonstrate the performance of a new mass spectrometry concept called zoom time-of-flight mass spectrometry (zoom-TOFMS). In our zoom-TOFMS instrument, we combine two complementary types of TOFMS: conventional, constant-energy acceleration (CEA) TOFMS and constant-momentum acceleration (CMA) TOFMS to provide complete mass-spectral coverage as well as enhanced resolution and duty factor for a narrow, targeted mass region, respectively. Alternation between CEA- and CMA-TOFMS requires only that electrostatic instrument settings (i.

View Article and Find Full Text PDF

Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification.

View Article and Find Full Text PDF

Fundamental aspects of constant-momentum acceleration time-of-flight mass spectrometry (CMA-TOFMS) are explored as a means to improve mass resolution. By accelerating all ions to the same momentum rather than to the same energy, the effects of the initial ion spatial and energy distributions upon the total ion flight time are decoupled. This decoupling permits the initial spatial distribution of ions in the acceleration region to be optimized independently, and energy focus, including ion turn-around-time error, to be accomplished with a linear-field reflectron.

View Article and Find Full Text PDF

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based, spatially dispersive MS technique in which ions are detected simultaneously along the plane of a spatially selective detector. In DOFMS, ions fly though the instrument and mass separate over a set period of time. The single flight time at which all ions are measured defines the specific m/z values that are detectable; the range of m/z values is dictated by the length of the spatially selective detector.

View Article and Find Full Text PDF

Work presented here demonstrates application of nanopipettes pulled to orifice diameters of less than 100 nm as electrospray ionization emitters for mass spectrometry. Mass spectrometric analysis of a series of peptides and proteins electrosprayed from pulled-quartz capillary nanopipette emitters with internal diameters ranging from 37 to 70 nm is detailed. Overall, the use of nanopipette emitters causes a shift toward the production of ions of higher charge states and leads to a reduction in width of charge-state distribution as compared to typical nanospray conditions.

View Article and Find Full Text PDF

The flowing atmospheric-pressure afterglow (FAPA) is a promising new source for atmospheric-pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA.

View Article and Find Full Text PDF

Resolution in time-of-flight mass spectrometry (TOFMS) is ordinarily limited by the initial energy and space distributions within an instrument's acceleration region and by the length of the field-free flight zone. With gaseous ion sources, these distributions lead to systematic flight-time errors that cannot be simultaneously corrected with conventional static-field ion-focusing devices (i.e.

View Article and Find Full Text PDF

The solution-cathode glow discharge (SCGD) is an optical emission source for atomic spectrometry comprised of a moderate-power atmospheric-pressure DC glow discharge sustained directly upon the surface of an electrically conductive solution. The SCGD boasts a simple, inexpensive design and has demonstrated detection limits similar to those of more conventional excitation sources used in atomic spectrometry. Although the analytical performance of the SCGD as an optical emission source is well characterized, the mechanism through which the discharge atomizes and excites analyte from the sample solution remains a point of debate.

View Article and Find Full Text PDF

A new method of detection for ion chromatography (IC) is described that couples replacement-ion chromatography (RIC) with an atmospheric-pressure solution-cathode glow discharge (SCGD). In the new instrument, a conventional suppressed IC arrangement is followed by a "replacement column" that consists of a cation-exchange micromembrane suppressor continuously regenerated with Li(2)SO(4). In this arrangement analytes are stoichiometrically converted to Li salts when they pass through the replacement column and are introduced into the SCGD, where they are detected indirectly by atomic emission spectrometry.

View Article and Find Full Text PDF

Rationale: Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass separation technique in which ions are spread across a spatially selective detector according to m/z. In this work, we investigate the practical mass range available for DOFMS with a finite-length detector.

Methods: A glow-discharge DOFMS instrument has been constructed for the analysis of atomic ions.

View Article and Find Full Text PDF

Distance-of-flight mass spectrometry (DOFMS) offers the advantages of physical separation of ions, array detection of ions, focusing of initial ion energy, great simplicity, and a truly unlimited mass range. DOFMS instrumentation is similar to that of time-of-flight mass spectrometry (TOFMS) and shares its ion-source versatility, batch analysis, and rapid spectral-generation rate. With constant-momentum ion acceleration and an ion mirror, there is a time at which ions of all mass-to-charge values are energy focused at their particular distances along the flight path.

View Article and Find Full Text PDF