Publications by authors named "Steven Day"

Extracorporeal Membrane Oxygenation (ECMO) serves as a crucial intervention for patients with severe pulmonary dysfunction by facilitating oxygenation and carbon dioxide removal. While traditional ECMO systems are effective, their large priming volumes and significant blood-contacting surface areas can lead to complications, particularly in neonates and pediatric patients. Microfluidic ECMO systems offer a promising alternative by miniaturizing the ECMO technology, reducing blood volume requirements, and minimizing device surface area to improve safety and efficiency.

View Article and Find Full Text PDF

Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.

View Article and Find Full Text PDF

The frequency and richness of the theories developed, tested, and used by researchers in an academic discipline exemplify several pertinent factors, namely, the growth, the maturity, the independence, the legitimacy, and the influence of the discipline. Although organizations have been working on projects for centuries, Project Management (PM) is a considerably new academic discipline with emerging research themes, models, methodologies, frameworks, and paradigms. These PM concepts are anchored on or reinforced by new or existing theories.

View Article and Find Full Text PDF

Non-invasive monitoring of pulmonary health may be useful for tracking several conditions such as COVID-19 recovery and the progression of pulmonary edema. Some proposed methods use impedance-based technologies to non-invasively measure the thorax impedance as a function of respiration but face challenges that limit the feasibility, accuracy, and practicality of tracking daily changes. In our prior work, we demonstrated a novel approach to monitor respiration by measuring changes in impedance from the back of the thigh.

View Article and Find Full Text PDF

Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have been performed to empirically and computationally study hemolysis in medical devices, such as valves and blood pumps, little is known about blood damage in microfluidic devices.

View Article and Find Full Text PDF

To address the unmet clinical need for pediatric circulatory support, we are developing an operationally versatile, hybrid, continuous-flow, total artificial heart ("Dragon Heart"). This device integrates a magnetically levitated axial and centrifugal blood pump. Here, we utilized a validated axial flow pump, and we focused on the development of the centrifugal pump.

View Article and Find Full Text PDF

Cellular senescence increases with aging and results in secretion of pro-inflammatory factors that induce local and systemic tissue dysfunction. We conducted the first preclinical trial in a relevant middle-aged nonhuman primate (NHP) model to allow estimation of the main translatable effects of the senolytic combination dasatinib (D) and quercetin (Q), with and without caloric restriction (CR). A multi-systemic survey of age-related changes, including those on immune cells, adipose tissue, the microbiome, and biomarkers of systemic organ and metabolic health are reported.

View Article and Find Full Text PDF

This study aims to determine whether astronauts who have not flown in space can provide an unbiased comparison to astronauts who have flown in space when analyzing long-term health outcomes such as incidence of chronic disease and mortality. Various propensity score methods failed to achieve good balance between groups, demonstrating that even with sophisticated rebalancing methods the group of non-flight astronauts cannot be demonstrated to be an unbiased comparison group for examining the effect of the hazards of spaceflight on incidence and mortality from chronic diseases.

View Article and Find Full Text PDF

Throughout evolution, organisms repeatedly developed elastic elements to power explosive body motions, overcoming ubiquitous limits on the power capacity of fast-contracting muscles. Seahorses evolved such a latch-mediated spring-actuated (LaMSA) mechanism; however, it is unclear how this mechanism powers the two complementary functions necessary for feeding: rapidly swinging the head towards the prey, and sucking water into the mouth to entrain it. Here, we combine flow visualization and hydrodynamic modelling to estimate the net power required for accelerating the suction feeding flows in 13 fish species.

View Article and Find Full Text PDF

Background: The purpose of this research is to address ongoing device shortfalls for pediatric patients by developing a novel pediatric hybrid total artificial heart (TAH). The valveless magnetically-levitated MCS device (Dragon Heart) has only two moving parts, integrates an axial and centrifugal blood pump into a single device, and will occupy a compact footprint within the chest for the pediatric patient population.

Methods: Prior work on the Dragon Heart focused on the development of pump designs to achieve hemodynamic requirements.

View Article and Find Full Text PDF

Dry electrodes offer an accessible continuous acquisition of biopotential signals as part of current in-home monitoring systems but often face challenges of high-contact impedance that results in poor signal quality. The performance of dry electrodes could be affected by electrode material and skin hydration. Herein, we investigate these dependencies using a circuit skin-electrode interface model, varying material and hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin.

View Article and Find Full Text PDF

Aligned collagen I (COL1) fibers guide tumor cell motility, influence endothelial cell morphology, control stem cell differentiation, and are a hallmark of cardiac and musculoskeletal tissues. To study cell response to aligned microenvironments in vitro, several protocols have been developed to generate COL1 matrices with defined fiber alignment, including magnetic, mechanical, cell-based, and microfluidic methods. Of these, microfluidic approaches offer advanced capabilities such as accurate control over fluid flows and the cellular microenvironment.

View Article and Find Full Text PDF

Clinically-available blood pumps and total artificial hearts for pediatric patients continue to lag well behind those developed for adults. We are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). The hybrid TAH design integrates both an axial and centrifugal blood pump within a single, compact housing.

View Article and Find Full Text PDF
Article Synopsis
  • Microfluidic tissue barrier models aim to improve physiological fluid flow compared to traditional open-well Transwell devices, which have limitations.
  • A new plug-and-play flow module has been developed to integrate microfluidic flow into existing open-well systems, allowing flexibility in experimental design while maintaining traditional protocols.
  • This design enables researchers to study cell behavior and dynamics, such as endothelial cell alignment and neutrophil migration, under flow conditions, potentially leading to broader adoption in engineering and bioscience labs.
View Article and Find Full Text PDF

Randomly oriented type I collagen (COL1) fibers in the extracellular matrix are reorganized by biophysical forces into aligned domains extending several millimeters and with varying degrees of fiber alignment. These aligned fibers can transmit traction forces, guide tumor cell migration, facilitate angiogenesis, and influence tissue morphogenesis. To create aligned COL1 domains in microfluidic cell culture models, shear flows have been used to align thin COL1 matrices (<50m in height) in a microchannel.

View Article and Find Full Text PDF

Advances in the integration of wearable devices in our daily life have led to the development of new electrode designs for biopotential monitoring. Historically, the development and testing of wearable electrodes for the acquisition of biopotential signals has been empirical, relying on experiments on human volunteers. However, the lack of explicit control on human variables, the intra-, and inter-subject variability complicates the understanding of the performance of these wearable electrodes.

View Article and Find Full Text PDF

Background: Mechanical circulatory support (MCS) devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), have become a vital therapeutic option in the treatment of end-stage heart failure for adult patients. Such therapeutic options continue to be limited for pediatric patients. Clinicians initially adapted or scaled existing adult devices for pediatric patients; however, these adult devices are not designed to support the anatomical structure and varying flow capacities required for this population and are generally operated "off-design," which risks complications such as hemolysis and thrombosis.

View Article and Find Full Text PDF

Introduction: Blood contacting medical devices, including rotary blood pumps, can cause shear-induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell-scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs).

Methods: We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD.

View Article and Find Full Text PDF

Objectives: Cancer incidence and mortality are important outcomes in the surveillance of long-term astronaut health. We compare cancer incidence rates, cancer-specific mortality rates, and cancer case-fatality ratios in US astronauts with those in the US general population.

Methods: We use standardised incidence ratios (SIRs) and standardised mortality ratios (SMRs) to index the incidence and mortality of various cancers against rates in the US general population, from the US astronaut cohort inception in April 1959 through 31 December 2017.

View Article and Find Full Text PDF

Space travelers are exposed to unique forms of ionizing radiation that pose potentially serious health hazards. Prior analyses have attempted to quantify excess mortality risk for astronauts exposed to space radiation, but low statistical power has frustrated inferences. If exposure to deep space radiation were causally linked to deaths due to two particular causes, e.

View Article and Find Full Text PDF