With the recent development of small particle stationary-phases and dedicated instrumentation, the combination of size-exclusion chromatography (SEC) with ultra-high performance liquid chromatography (UHPLC) technology has been realized. It opened up a new polymer analysis technique called UHP-SEC. Although high resolution and fast analysis can be achieved, the multi-solvent suitability for a given column was limited to either organic or aqueous eluents.
View Article and Find Full Text PDFTo date, few studies have examined the role of sea spray aerosols (SSAs) in human exposure to harmful and beneficial marine compounds. Two groups of phycotoxins (brevetoxins and ovatoxins) have been reported to induce respiratory syndromes during harmful algal blooms. The aerosolization and coastal air concentrations of other common marine phycotoxins have, however, never been examined.
View Article and Find Full Text PDFA promising concept for sampling contaminants of emerging concern (CECs) using a home-made Simple Teabag Equilibrium Passive Sampler (STEPS) containing hydrophilic divinylbenzene (h-DVB) sorbent is presented and evaluated for application in estuarine systems. The uptake of a multi-class mixture of CECs with a broad polarity range (Log P ranging from -0.1 to 9.
View Article and Find Full Text PDFFaecal metabolomics markedly emerged in clinical as well as analytical chemistry through the unveiling of aberrations in metabolic signatures as reflection of variance in gut (patho)physiology and beyond. Logistic hurdles, however, hinder the analysis of stool samples immediately following collection, inferring the need of biobanking. Yet, the optimum way of storing stool material remains to be determined, in order to conserve an accurate snapshot of the metabolome and circumvent artifacts regarding the disease and parameter(s) under observation.
View Article and Find Full Text PDFRespiratory exposure to marine phycotoxins is of increasing concern. Inhalation of sea spray aerosols (SSAs), during harmful and blooms induces respiratory distress among others. The biogenics hypothesis, however, suggests that regular airborne exposure to natural products is health promoting via a downregulation of the mechanistic target of rapamycin (mTOR) pathway.
View Article and Find Full Text PDFHydrophilic divinylbenzene (DVB) (Bakerbond) has surfaced as a promising sorbent for active sampling of analytes from aqueous matrices over a very broad polarity range. Given this, hydrophilic DVB may likewise offer potential for passive sampling, if sorbent/water partitioning coefficients () were to be available. In this work, static exposure batch experiments were performed to quantitatively study the equilibrium sorption of 131 environmentally relevant organic contaminants ( values ranging from -1.
View Article and Find Full Text PDFKnowledge about the occurrence of emerging organic micropollutants in the marine environment is still very limited, especially when focusing on the Belgian Part of the North Sea (BPNS). This study therefore optimized and validated a Speedisk® based SPE and LC-Q-Orbitrap HRMS method to tackle the challenge of measuring the expected ultra-trace concentrations in seawater. This method was applied to 18 samples collected at different locations in the open sea and harbor of the BPNS.
View Article and Find Full Text PDFA generic extraction and UHPLC-Q-Orbitrap™-HRMS method was developed for four insect species (mealworm, grasshopper, house cricket and black soldier fly) analyzing a large spectrum of organic chemical contaminants, including pesticides (n = 25), (veterinary) drugs (n = 29), and mycotoxins (n = 23). To prove the method as 'fit-for-purpose', a successful validation was performed, both qualitatively, by determining the screening detection limit (SDL), selectivity and specificity, as well as semi-quantitatively, by assessing the within-day precision (relative standard deviation (RSD)) and recovery. For both the mealworm, grasshopper, house cricket and black soldier fly, 64, 61, 59 and 62 compounds were detected at the respective SDL levels (1-100 μg kg), predominantly below existing maximum residue limits for other edible matrices.
View Article and Find Full Text PDFTo estimate mixture effects caused by the high number of chemicals simultaneously present in the environment, methods for routine effect assessment of environmentally realistic contaminant mixtures are needed. We repeatedly exposed the marine diatom Phaeodactylum tricornutum to Speedisk passive sampler extracts and observed statistically significant growth stimulation up to 6 and 7% for samples from inside and outside the harbor of Zeebrugge, respectively. These effects were found at summed contaminant concentrations (159-166 ng L ) that were within a 1.
View Article and Find Full Text PDFPlasticizers and other plastics additives have been extensively used as ingredients of plastics and are as a result thereof easily released in the aquatic environment, due to different physical diffusion processes. In this context, a dedicated method was developed for the simultaneous quantification of 27 known and a virtually unlimited number of unknown alkylphenols, Bisphenol A and phthalates in 2 aquatic matrices, i.e.
View Article and Find Full Text PDFAmmonia recovery from urine avoids the need for nitrogen removal through nitrification/denitrification and re-synthesis of ammonia (NH) via the Haber-Bosch process. Previously, we coupled an alkalifying electrochemical cell to a stripping column, and achieved competitive nitrogen removal and energy efficiencies using only electricity as input, compared to other technologies such as conventional column stripping with air. Direct liquid-liquid extraction with a hydrophobic gas membrane could be an alternative to increase nitrogen recovery from urine into the absorbent while minimizing energy requirements, as well as ensuring microbial and micropollutant retention.
View Article and Find Full Text PDFIn recent years, metabolomics has surfaced as an innovative research strategy in human metabolism, whereby selection of the biological matrix and its inherent metabolome is of crucial importance. However, focusing on a single matrix may imply that relevant molecules of complementary physiological pathways, covered by other matrices, are missed. To address this problem, this study presents a unique multi-matrix platform for polar metabolic fingerprinting of feces, plasma and urine, applying ultra-high performance liquid-chromatography coupled to hybrid quadrupole-Orbitrap high-resolution mass spectrometry, that is able to achieve a significantly higher coverage of the system's metabolome and reveal more significant results and interesting correlations in comparison with single-matrix analyses.
View Article and Find Full Text PDFThe lack of adequate strategies for monitoring endocrine disrupting compounds (EDCs) in the aquatic environment is emphasized in the European Water Framework Directive. In this context, a new UHPLC-HR-Q-Orbirtrap-MS multi-residue method was developed for the simultaneous measurement of 70 steroidal EDCs in two aquatic matrices, i.e.
View Article and Find Full Text PDF