Purpose: To identify the laser programming strategy that will achieve optimal refractive outcomes of LASIK with a topography-guided laser for eyes with a disparity between cylinder measured by manifest refraction and cylinder measured by topography.
Setting: Six surgeons at 5 clinical sites in the USA.
Design: Retrospective data review.
Purpose: To assess longitudinal refractive, keratometric, and topographic changes following KAMRA small-aperture inlay implantation.
Design And Setting: Prospective study at a single site refractive surgery center.
Methods: Fifty patients underwent KAMRA small-aperture corneal inlay implantation for the correction of presbyopia.
Purpose: To analyze the impact of the three latest U.S. Food and Drug Administration (FDA)-approved lasers on patient-reported outcomes after LASIK.