IEEE Trans Ultrason Ferroelectr Freq Control
December 2022
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.
View Article and Find Full Text PDFArray transducers can allow wavelength and frequency selectivity and can be used to generate different types of waves, such as ultrasonic bulk or guided waves. Dual-array transducers consist of two interlaced arrays, where the elements of each array are electrically connected. Therefore, by driving each array with a pair of phased pulses one can achieve a degree of wave generation control that allows unidirectional generation, unlike single array transducers that generate waves in both 0° and 180° directions with respect to the array's longitudinal axis.
View Article and Find Full Text PDFThe interaction of guided waves with wall thinning can be complex, depending on the thinning geometry and the frequency. At a high frequency-thickness, when a shear-horizontal (SH) guided wave mode impinges upon a tapered wall thinning region, there is mode conversion to other propagating SH modes, either in reflection or transmission, which heavily depends on the shape of the taper. In this paper, we have combined the reciprocity theorem of elastodynamics and the theory of multiple reflections, in order to analytically calculate the scattered SH wavefield in plates, due to the interaction with an arbitrary tapered thinning.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2021
Shear horizontal (SH) waves are commonly generated by periodic permanent magnet (PPM) electromagnetic acoustic transducers (EMATs) in metallic media. Conventional PPM EMATs generate ultrasonic waves, which simultaneously propagate both forward and backward. This can be an undesirable characteristic, since the backward wave can be eventually reflected, reaching the receiver transducer where it can mix with the signal of interest.
View Article and Find Full Text PDFWhen shear horizontal ultrasonic guided waves interact with thickness discontinuities in plates, the reflected and transmitted wavefields can be composed of several modes due to mode conversion. It is known that in a plate with a symmetric discontinuity, with respect to the plate's mid-plane, mode conversion is restricted to modes that share the same symmetry as the incident mode. In this paper, we use an analytical model based on the reciprocity principle and finite element analysis to investigate mode conversion due to the interaction with different types of discontinuity, namely, non-symmetric, symmetric and geometrically symmetric but with opposite boundary conditions, that is one side of the discontinuity free and the other rigidly fixed.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
December 2020
Periodic permanent magnet (PPM) array electromagnetic acoustic transducers (EMATs) can efficiently generate and receive shear horizontal (SH) ultrasonic waves. Conventional PPM EMATs typically generate waves which simultaneously propagate both forward and backward. This can complicate the received signals and make it difficult to locate the position of scatterers.
View Article and Find Full Text PDFMammographic breast density (MBD) is an important imaging biomarker of breast cancer risk, but it has been suggested that increased MBD is not a genuine finding once corrected for age and body mass index (BMI). This study examined the association of various factors, including both residing in and working in the urban setting, with MBD. Questionnaires were completed by 1144 women attending for mammography at the London Breast Institute in 2012-2013.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2020
A phased electromagnetic acoustic transducer (EMAT) array system has been developed for the detection and characterization of surface-breaking defects. An array of four linear coils that are individually controlled is used to generate a Rayleigh wave. The high-current electronics combined with the coil designs enables the array to generate either narrowband or broadband signals, and controlling the phase delay between the channels makes it possible to change the ultrasound wavelength without requiring the physical separation of the coils to be changed.
View Article and Find Full Text PDFAccurate average flow velocity determination is essential for flow measurement in many industries, including automotive, chemical, and oil and gas. The ultrasonic transit-time method is common for average flow velocity measurement, but current limitations restrict measurement accuracy, including fluid dynamic effects from unavoidable phenomena such as turbulence, swirls or vortices, and systematic flow meter errors in calibration or configuration. A new spatial averaging method is proposed, based on flexural ultrasonic array transducer technology, to improve measurement accuracy and reduce the uncertainty of the measurement results.
View Article and Find Full Text PDFThe flexural ultrasonic transducer comprises a piezoelectric ceramic disc bonded to a membrane. The vibrations of the piezoelectric ceramic disc induce flexural modes in the membrane, producing ultrasound waves. The transducer is principally utilized for proximity or flow measurement, designed for operation at atmospheric pressure conditions.
View Article and Find Full Text PDFThis data article reports the data for reflection and transmission coefficients of the SH0 and SH1 ultrasonic guided waves modes due to their interaction with tapered wall thinning in aluminium plates. Several thinning depths and edge taper angles were machined, at the total of 35 different samples. Periodic permanent magnet array electromagnet acoustic transducers were used to generate and receive the waves.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2018
Shear horizontally (SH) guided waves, generated by periodic permanent magnet arrays, have been used previously in nondestructive evaluation of metal plates and pipes. When an SH guided wave interacts with a defect or a change in sample thickness, the incident SH wave may undergo mode conversion. Analysis of mode conversion is complicated, due to the interference of several propagating modes in the received signal that can often temporally overlap.
View Article and Find Full Text PDFFlexural ultrasonic transducers are principally used as proximity sensors and for industrial metrology. Their operation relies on a piezoelectric ceramic to generate a flexing of a metallic membrane, which delivers the ultrasound signal. The performance of flexural ultrasonic transducers has been largely limited to excitation through a short voltage burst signal at a designated mechanical resonance frequency.
View Article and Find Full Text PDFElectromagnetic acoustic transducers (EMATs) are non-contact, ultrasonic transducers that are usually kept within 5 mm from the sample surface to obtain a sufficient signal-to-noise ratio (SNR). One important issue associated with operation on a ferromagnetic plate is that the strong attraction force from the magnet can affect measurements and make scanning difficult. This paper investigates a method to generate fundamental, symmetric Lamb waves on a ferromagnetic plate.
View Article and Find Full Text PDFObjective: Although mesenchymal stem/stromal cells represent a promising therapeutic strategy for acute respiratory distress syndrome, clinical translation faces challenges, including scarcity of bone marrow donors, and reliance on bovine serum during mesenchymal stem/stromal cell proliferation. We wished to compare mesenchymal stem/stromal cells from human umbilical cord, grown in xeno-free conditions, with mesenchymal stem/stromal cells from human bone marrow, in a rat model of Escherichia coli pneumonia. In addition, we wished to determine the potential for umbilical cord-mesenchymal stem/stromal cells to reduce E.
View Article and Find Full Text PDFThree designs for electrodynamic flexural transducers (EDFT) for air-coupled ultrasonics are presented and compared. An all-metal housing was used for robustness, which makes the designs more suitable for industrial applications. The housing is designed such that there is a thin metal plate at the front, with a fundamental flexural vibration mode at ∼50 kHz.
View Article and Find Full Text PDFBackground: Data from providers of private cancer care are not yet formally included in English cancer registration data. This study aimed to test the exchange of breast cancer data from one Hospital Corporation of America International (HCAI) hospital in London with the cancer registration system and assess the suitability of these data for comparative analyses of case mix and adjusted survival.
Methods: Data on 199 London women receiving 'only HCAI care', 278 women receiving 'some HCAI care' (HCAI and other services), and 31,234 other London women diagnosed between 2005 and 2011 could be identified and compared.
Introduction: Life expectancies in the UK are increasing and with this there is an increasing elderly population with more complex co-morbidity. Emergency surgery in the elderly is challenging in terms of decision making, managing co-morbidity and post-operative rehabilitation with high morbidity and mortality. To optimise service design and development, it is important to understand the changing pattern of emergency surgical care for this group.
View Article and Find Full Text PDFAim: We propose long-term -ostomy rate following laparoscopic rectal cancer resection must be included as an overall quality indicator of treatment in conjunction with frequently reported and readily available end points.
Method: A database was collated prospectively of consecutive rectal cancer resections over a 6-year period. Recorded data included pre-operative MRI (tumour stage and height from the anal-verge), as well as demographics, treatment, local recurrence rate, survival and -ostomy rate as the primary outcome measure.
IEEE Trans Ultrason Ferroelectr Freq Control
April 2015
Wetted ultrasonic transit time flow meters typically consist of one or more pairs of transducers, containing piezoelectric elements, which alternate between transmitting and detecting an ultrasonic pulse. Typical piezoelectric materials and the adhesives used to attach the piezoelectric element in such devices can be damaged by hostile environments, such as extreme temperature, potentially limiting possible applications of ultrasonic flow measurement techniques. We have investigated a design for a flow meter with an integrated thermal buffer waveguide consisting of five parallel stainless steel strips.
View Article and Find Full Text PDFThe use of phased array methods are commonplace in ultrasonic applications, where controlling the variation of the phase between the narrowband emitters in an array facilitates beam steering and focusing of ultrasonic waves. An approach is presented here whereby emitters of alternating polarity arranged in a one-dimensional array are pulsed simultaneously, and have sufficiently wide, controlled bandwidth to emit a two-dimensional wave. This pulsed approach provides a rapid means of simultaneously covering a region of space with a wave-front, whereby any wave that scatters or reflects off a body to a detector will have a distinct arrival time and frequency.
View Article and Find Full Text PDFJ Public Health (Oxf)
December 2013
Background: We investigated socioeconomic and ethnic inequalities in screen-detected breast cancer in London-a city with relatively low breast cancer screening uptake and a diverse population.
Methods: Data on 11 957 breast cancers in London women aged 50-64 between 1998 and 2005 were extracted from the Thames Cancer Registry. We investigated the relationship between socioeconomic deprivation and the incidence and 5-year relative survival of screen-detected and non screen-detected cancers.
IEEE Trans Ultrason Ferroelectr Freq Control
January 2012
The propagation of Lamb waves generated by a pulsed laser beam in an aluminum sheet is modeled using finite element analysis, and the interaction with defects is studied and compared to experimental results. The ultrasonic Lamb waves are detected by an electromagnetic acoustic transducer (EMAT). The frequency content of the received wave is shown to be enhanced when the generation point is situated directly over the defect in both the modeled and experimental cases.
View Article and Find Full Text PDFBackground: Breast screening uptake in London is below the Government's target of 70% and we investigate whether ethnicity affects this. Information on the ethnicity for the individual women invited is unavailable, so we use an area-based method similar to that routinely used to derive a geographical measure for socioeconomic deprivation.
Methods: We extracted 742,786 observations on attendance for routine appointments between 2004 and 2007 collected by the London Quality Assurance Reference Centre.