Background: Current fiducial markers (FMs) in external-beam radiotherapy (EBRT) for prostate cancer (PCa) cannot be positively visualized on magnetic resonance imaging (MRI) and create dose perturbation and significant imaging artifacts on computed tomography (CT) and MRI. We report our initial experience with clinical imaging of a novel multimodality FM, NOVA.
Methods: We tested Gold Anchor [G-FM], BiomarC [carbon, C-FM], and NOVA FMs in phantoms imaged with kilovoltage (kV) X-rays, transrectal ultrasound (TRUS), CT, and MRI.
Purpose: To conduct a population-level analysis of surgical and endovascular interventions for symptomatic uterine leiomyomata by using administrative data from outpatient medical encounters.
Materials And Methods: By using administrative data from all outpatient hospital encounters in California (2005-2011) and Florida (2005-2014), all patients in the outpatient setting with symptomatic uterine leiomyomata were identified. Patients were categorized as undergoing hysterectomy, myomectomy, uterine artery embolization (UAE), or no intervention.
Purpose: To investigate from a population health perspective the effects of transjugular intrahepatic portosystemic shunt (TIPS) creation on recurrent variceal bleeding and survival in patients with cirrhosis.
Materials And Methods: Patients with cirrhosis who presented to outpatient and acute-care hospitals in California (2005-2011) and Florida (2005-2014) with variceal bleeding comprised the study cohort. Patients entered the study cohort at their first presentation for variceal bleeding; all subsequent hospital encounters were then evaluated to determine subsequent interventions, complications, and mortality data.
Purpose: Inferior vena cava (IVC) filters are placed to reduce venous thromboembolism (VTE)-related morbidity and mortality, though the evidence supporting this practice is limited. In 2010, the Food and Drug Administration (FDA) released a device safety advisory due to the risk of filter migration, fracture, and thrombosis with long-term use. The purpose of this study was to evaluate trends and predictors for IVCF placement and retrieval over a 10-year time period from a population health perspective.
View Article and Find Full Text PDFPercutaneous image-guided ablation is now commonly performed in many institutions for the treatment of hepatocellular carcinoma, liver metastases, and renal cell carcinoma in select patients. Accurate interpretation of post-ablation imaging is of supreme importance because treatment algorithms for these diseases rely heavily on imaging to guide management decisions. The purpose of this pictorial essay is to provide abdominal imagers with a review of the indications for percutaneous ablation in the abdomen, a basic overview of ablation modalities in clinical use today, the expected post-ablation imaging findings in the liver and kidney, and potential complications of hepatic and renal ablation procedures.
View Article and Find Full Text PDFThis study reports the differences in evolution and course of multiple pseudoaneurysms (PAs) and an axillary arteriovenous fistula (AVF) after penetrating vascular trauma due to shotgun injury to the head and neck. We describe the unusual case of a young man who, following penetrating shotgun injuries to the head and neck, developed multiple PAs of the common carotid, vertebral and superficial temporal arteries as well as an axillary AVF. Serial angiographic follow-up studies documented differences in time of occurrence, evolution and course of these lesions.
View Article and Find Full Text PDFIntroduction: Penetrating gunshot injuries (GSI) to supra-aortic arteries that cause life-threatening blood loss or major neurologic deficits are increasingly managed using modern endovascular treatment (EVT). We report our experience with EVT of acute GSIs and review the existing literature.
Methods: Emergency EVT was performed in nine of 10 patients (7 men, age 17-50 years) with acute GSIs to supra-aortic arteries requiring acute management.
Objective: Medical physics instruction for diagnostic radiology residency at our institution has been redesigned with an interactive and image-based approach that encourages clinical application. The new medical physics curriculum spans the first 3 years of radiology residency and is integrated with the core didactic curriculum.
Conclusion: Salient features include clinical medical physics conferences, fundamentals of medical physics lectures, practicums, online modules, journal club, and a final review before the American Board of Radiology core examination.
A solar cell based on a hybrid nanowire–film architecture consisting of a vertically aligned array of InGaN/GaN multi-quantum well core–shell nanowires which are electrically connected by a coalesced p-InGaN canopy layer is demonstrated. This unique hybrid structure allows for standard planar device processing, solving a key challenge with nanowire device integration, while enabling various advantages by the nanowire absorbing region such as higher indium composition InGaN layers by elastic strain relief, more efficient carrier collection in thinner layers, and enhanced light trapping from nano-scale optical index changes. This hybrid structure is fabricated into working solar cells exhibiting photoresponse out to 2.
View Article and Find Full Text PDFVertically aligned InGaN/GaN nanorod light emitting diode (LED) arrays were created from planar LED structures using a new top-down fabrication technique consisting of a plasma etch followed by an anisotropic wet etch. The wet etch results in straight, smooth, well-faceted nanorods with controllable diameters and removes the plasma etch damage. 94% of the nanorod LEDs are dislocation-free and a reduced quantum confined Stark effect is observed due to reduced piezoelectric fields.
View Article and Find Full Text PDFThe purpose of this pictorial essay is to review the surgical technique, postoperative anatomy, and potential complications of the laparoscopic sleeve gastrectomy. As the laparoscopic sleeve gastrectomy becomes an increasingly popular bariatric surgery, it is important for radiologists to familiarize themselves with the procedure and possible complications.
View Article and Find Full Text PDFThe availability of a highly accurate, rapid, point-of-care test for hepatitis C virus (HCV) may be useful in addressing the problem of under-diagnosis of HCV, by increasing opportunities for testing outside of traditional clinical settings. A new HCV rapid test device (OraQuick® HCV Rapid Antibody Test), approved recently in Europe for use with venous blood, fingerstick blood, serum, plasma, or oral fluid was evaluated in a multi-center study and performance compared to established laboratory-based tests for detection of HCV. The HCV rapid test was evaluated in prospective testing of subjects with signs and/or symptoms of hepatitis, or who were at risk for hepatitis C using all 5 specimen types.
View Article and Find Full Text PDFBackground: Chagas disease, caused by the parasite Trypanosoma cruzi, represents a serious blood safety problem due to increasing immigration from Latin America. The Food and Drug Administration recently recommended implementation of Chagas antibody screening for US donors as soon as a suitable assay is licensed. An anonymized preclinical study of a prototype T.
View Article and Find Full Text PDFBackground: In 1996, the Ortho HCV Version 3.0 ELISA Test System (HCV 3.0 EIA) was licensed in the United States for donor screening but was neither mandated nor universally implemented.
View Article and Find Full Text PDF© LitMetric 2025. All rights reserved.