Publications by authors named "Stephen Kry"

Background: A passive dosimeter framework for the measurement of dose in carbon ion beams has yet to be characterized or implemented for regular use.

Purpose: This work determined the dose calculation correction factors for absorbed dose in thermoluminescent dosimeters (TLDs) in a therapeutic carbon ion beam. TLD could be a useful tool for remote audits, particularly in the context of clinical trials as new protocols are developed for carbon ion radiotherapy.

View Article and Find Full Text PDF

Background And Purpose: With the availability of commercial electronic portal imaging detector-based in vivo dosimetry (EPID-based IVD) solutions, many radiotherapy departments are adopting this technology. However, comprehensive commissioning guidance is lacking. This study aims to provide a protocol for testing the accuracy and sensitivity of EPID-based IVD systems.

View Article and Find Full Text PDF

Background: The Joint AAPM-ESTRO TG-360 is developing a quantitative framework to evaluate treatment verification systems used for patient-specific quality assurance (PSQA). A subgroup was commissioned to determine which potential failure modes had the greatest risk to treatment quality and safety, and therefore should be evaluated as part of the PSQA verification.

Purpose: To create an extensive database of potential radiotherapy failure modes that should be detected by PSQA and to determine their relative importance for maximizing treatment quality.

View Article and Find Full Text PDF

Purpose: The Imaging Radiation Oncology Core (IROC) head and neck (H&N) phantom is used to credential institutions for intensity modulated radiation therapy delivery for all anatomic sites where delivery of modulated therapy is a primary challenge. This study evaluated how appropriate the use of this phantom is for varied clinical anatomy by evaluating how closely the IROC H&N phantom described clinical dose errors from beam modeling compared with various anatomic sites.

Methods And Materials: The multileaf collimator (MLC) offset, transmission, percent depth dose, and 7 additional beam modeling parameters for a Varian accelerator were modified in RayStation to match community data at the 2.

View Article and Find Full Text PDF

Historically, total body irradiation (TBI) has been delivered using static, parallel opposed photon beams (2D-TBI). Recently, centers have increasingly used intensity-modulated radiation therapy (IMRT) techniques for TBI. Relative to 2D-TBI, IMRT can reduce doses to critical organs (i.

View Article and Find Full Text PDF

Background: Optically stimulated luminescent dosimeters (OSLDs) can be bleached and reused, but questions remain about the effects of repeated bleaching and fractionation schedules on OSLD performance.

Purpose: The aim of this study was to investigate how light sources with different wavelengths and different fractionation schemes affect the performance of reused OSLDs.

Methods: OSLDs (N = 240) were irradiated on a cobalt-60 beam in different step sizes until they reached an accumulated dose of 50 Gy.

View Article and Find Full Text PDF

Background: Clinical intensity modulated radiation therapy plans have been described using various complexity metrics to help identify problematic radiotherapy plans. Most previous studies related to the quantification of plan complexity and their utility have relied on institution-specific plans which can be highly variable depending on the machines, planning techniques, delivery modalities, and measurement devices used. In this work, 1723 plans treating one of only four standardized geometries were simultaneously analyzed to investigate how radiation plan complexity metrics vary across four different sets of common objectives.

View Article and Find Full Text PDF

. This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification..

View Article and Find Full Text PDF

Dosimetry audits for passive motion management require dynamically-acquired measurements in a moving phantom to be compared to statically calculated planned doses. This study aimed to characterise the relationship between planning and delivery errors, and the measured dose in the Imaging and Radiation Oncology Core (IROC) thorax phantom, to assess different audit scoring approaches. Treatment plans were created using a 4DCT scan of the IROC phantom, equipped with film and thermoluminescent dosimeters (TLDs).

View Article and Find Full Text PDF

Purpose: As carbon ion radiotherapy increases in use, there are limited phantom materials for heterogeneous or anthropomorphic phantom measurements. This work characterized the radiological clinical equivalence of several phantom materials in a therapeutic carbon ion beam.

Methods: Eight materials were tested for radiological material-equivalence in a carbon ion beam.

View Article and Find Full Text PDF

Purpose: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom.

Methods And Materials: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (∼1.

View Article and Find Full Text PDF

Purpose: To quantify the impact of treatment planning system beam model parameters, based on the actual spread in radiotherapy community data, on clinical treatment plans and determine which complexity metrics best describe the impact beam modeling errors have on dose accuracy.

Methods: Ten beam modeling parameters for a Varian accelerator were modified in RayStation to match radiotherapy community data at the 2.5, 25, 50, 75, and 97.

View Article and Find Full Text PDF

Purpose: To analyze trends in institutional performance and failure modes for the Imaging and Radiation Oncology Core's (IROC's) proton liver phantom.

Materials And Methods: Results of 66 phantom irradiations from 28 institutions between 2015 and 2020 were retrospectively analyzed. Univariate analysis and random forest models were used to associate irradiation conditions with phantom results.

View Article and Find Full Text PDF

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene ($~1.

View Article and Find Full Text PDF

Purpose: Our purpose was to identify variations in the clinical use of automatically generated contours that could be attributed to software error, off-label use, or automation bias.

Methods And Materials: For 500 head and neck patients who were contoured by an in-house automated contouring system, Dice similarity coefficient and added path length were calculated between the contours generated by the automated system and the final contours after editing for clinical use. Statistical process control was used and control charts were generated with control limits at 3 standard deviations.

View Article and Find Full Text PDF

Clinical trials have been the center of progress in modern medicine. In oncology, we are fortunate to have a structure in place through the National Clinical Trials Network (NCTN). The NCTN provides the infrastructure and a forum for scientific discussion to develop clinical concepts for trial design.

View Article and Find Full Text PDF

Purpose: Few reports describe the risks of late ocular toxicities after radiation therapy (RT) for childhood cancers despite their effect on quality of life. The Pediatric Normal Tissue Effects in the Clinic (PENTEC) ocular task force aims to quantify the radiation dose dependence of select late ocular adverse effects. Here, we report results concerning retinopathy, optic neuropathy, and cataract in childhood cancer survivors who received cranial RT.

View Article and Find Full Text PDF

Purpose: The Medical Physics Working Group of the Radiation Therapy Study Group at the Japan Clinical Oncology Group is currently developing a virtual audit system for intensity-modulated radiation therapy dosimetry credentialing. The target dosimeters include films and array detectors, such as ArcCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA) and Delta4 (ScandiDos, Uppsala, Sweden). This pilot study investigated the feasibility of our virtual audit system using previously acquired data.

View Article and Find Full Text PDF

FLASH radiation therapy (FLASH-RT), delivered with ultrahigh dose rate (UHDR), may allow patients to be treated with less normal tissue toxicity for a given tumor dose compared with currently used conventional dose rate. Clinical trials are being carried out and are needed to test whether this improved therapeutic ratio can be achieved clinically. During the clinical trials, quality assurance and credentialing of equipment and participating sites, particularly pertaining to UHDR-specific aspects, will be crucial for the validity of the outcomes of such trials.

View Article and Find Full Text PDF

Purpose: Hazard scenarios were created to assess and reduce the risk of planning errors in automated planning processes. This was accomplished through iterative testing and improvement of examined user interfaces.

Methods: Automated planning requires three user inputs: a computed tomography (CT), a prescription document, known as the service request, and contours.

View Article and Find Full Text PDF

Purpose: We describe the methods used to estimate the accuracy of dosimetric data found in literature sources used to construct the Pediatric Normal Tissue Effects in the Clinic (PENTEC) dose-response models, summarize these findings of each organ-specific task force, describe some of the dosimetric challenges and the extent to which these efforts affected the final modeling results, and provide guidance on the interpretation of the dose-response results given the various dosimetric uncertainties.

Methods And Materials: Each of the PENTEC task force medical physicists reviewed all the journal articles used for dose-response modeling to identify, categorize, and quantify dosimetric uncertainties. These uncertainties fell into 6 broad categories.

View Article and Find Full Text PDF

Aim Of The Study: To elucidate the important factors and their interplay that drive performance on IMRT phantoms from the Imaging and Radiation Oncology Core (IROC).

Methods: IROC's IMRT head and neck phantom contains two targets and an organ at risk. Point and 2D dose are measured by TLDs and film, respectively.

View Article and Find Full Text PDF

Background And Purpose: The Global Clinical Trials RTQA Harmonization Group (GHG) set out to evaluate and prioritize clinical trial quality assurance.

Methods: The GHG compiled a list of radiotherapy quality assurance (QA) tests performed for proton and photon therapy clinical trials. These tests were compared between modalities to assess whether there was a need for different types of assessments per modality.

View Article and Find Full Text PDF

The field of human space travel is in the midst of a dramatic revolution. Upcoming missions are looking to push the boundaries of space travel, with plans to travel for longer distances and durations than ever before. Both the National Aeronautics and Space Administration (NASA) and several commercial space companies (e.

View Article and Find Full Text PDF