Publications by authors named "Stephen Bayne"

With the advancement of technology, electric equipment and loads have become more sensitive to problems related to power quality, such as voltage sag, swell, imbalances, and harmonics. To detect faults and to protect sensitive loads from these voltage distortions, a Dynamic Voltage Restorer (DVR) series compensator is among the best available cost-effective solutions. One of the main goals of the DVR is to achieve a control structure that is robust, stable, and can handle properly the disturbances (e.

View Article and Find Full Text PDF

Objectives: The long history of the Academy of Dental Materials (ADM) is documented with its strategies (a) to rapidly communicate science among its members, (b) to establish special awards to stimulate new science, and (c) to develop new dental materials scientists.

Methods: We searched the history of the last 35 years of the ADM newsletters, transactions, journals, and officer notes. We document the (a) presidents, (b) meeting history, (c) membership growth, and (d) development of special awards through 2019 with the recent creation of the ADM Marshall Post-Doctoral Award.

View Article and Find Full Text PDF

Unattended, compact, terrestrial and space sensors require sources that have high energy and power densities to continuously operate for 3 to 99 years depending on application. Currently, chemical sources cannot fully satisfy these applications, especially in solid state form. Betavoltaic (βV) nuclear batteries using β-emitting radioisotopes possess energy densities 1000 times greater than conventional chemical sources.

View Article and Find Full Text PDF

Of all of the material parameters associated with a semiconductor, the carrier lifetime is by far the most complex and dynamic, being a function of the dominant recombination mechanism, the equilibrium number of carriers, the perturbations in carriers (e.g., carrier injection), and the temperature, to name the most prominent variables.

View Article and Find Full Text PDF

Statement Of The Problem: Recent interest in shaded zirconia has raised questions about the relative stability of the tetragonal phase after colorant oxide additions.

Purpose: The purpose of this in vitro study was to evaluate the effects of fatigue cycling on the stability of a commercially available dental zirconia (Procera) in both unshaded and shaded compositions by measuring the change in biaxial flexural strength (BFS) after 500 000 cycles at 80-N loads and in phase composition as detected by x-ray diffraction (XRD).

Material And Methods: Partially stabilized zirconia disks (NobelProcera) were fabricated in unshaded and shaded forms (12 mm diameter × 0.

View Article and Find Full Text PDF

With the advent of modern power semiconductor switching elements, the envelope defining "high power" is an ever increasing quantity. Characterization of these semiconductor power devices generally falls into two categories: switching, or transient characteristics, and static, or DC characteristics. With the increasing native voltage and current levels that modern power devices are capable of handling, characterization equipment meant to extract quasi-static IV curves has not kept pace, often leaving researchers with no other option than to construct ad hoc curve tracers from disparate pieces of equipment.

View Article and Find Full Text PDF

Obtaining accurate collector to emitter voltage measurements when characterizing high voltage silicon carbide (SiC) devices requires the ability to measure voltages in the range of zero to 10 V while the device is in the on-state and the ability to withstand ultra-high voltages while the device is in the off-state. This paper presents a specialized voltage probe capable of accurately measuring the aforementioned range. A comparison is made between the proposed probe and other commonly used high voltage probe alternatives in relation to high voltage SiC device testing.

View Article and Find Full Text PDF

Statement Of Problem: Shaded versions of dental zirconia may improve initial color matching to teeth, but might change color with cyclic mechanical loading.

Purpose: The purpose of this study was to measure the color of unshaded and shaded zirconia dental ceramic before and after cyclic mechanical loading and calculate color differences (ΔE).

Material And Methods: Disk-shaped specimens (N = 30, Nobel Procera, 0.

View Article and Find Full Text PDF

This paper describes the design and implementation of a small-scale pulsed power system specifically intended to evaluate the suitability of experimental silicon and silicon carbide high power Super Gate Turn Off thyristors for high action (500 A(2) s and above) pulsed power applications where energy is extracted from a storage element in a rapid and controlled manner. To this end, six of each type of device was placed in a controlled three phase rectifier circuit which was in turn connected to an aircraft ground power motor-generator set and subjected to testing protocols with varying power levels, while parameters such as offset firing angle were varied.

View Article and Find Full Text PDF

Evidence-based dentistry (EBD) is reviewed in depth to underscore the limitations for evidence-based dental materials information that exist at this time. Anecdotal estimates of evidence for dental practice are in the range of 8 percent to 10 percent. While the process of evaluating the literature base for dental evidence began 20 years ago, it was not practical to implement it until high-speed wireless connections, open access to journals, and omnipresent connections via smart phones became a reality.

View Article and Find Full Text PDF

A high energy, modular, completely automated test bed with integrated data acquisition and characterization systems was successfully designed in order to perform both safe operating area as well as very high volume reliability testing on experimental silicon carbide Super Gate Turn Off (SGTO) thyristors. Although the system follows a modular design philosophy, with each functional block acting as a peripheral to a main control module and can be adapted to arbitrary power and pulse width levels, for the specific SGTO devices initially evaluated it was configured to have the device discharge variable current levels of up to 6 kA into a 0.5 Ω resistive load with a relatively square pulse fixed at 100 μs full width at half maximum delivering energy levels up to 1.

View Article and Find Full Text PDF

Purpose: Manual toothbrushes (MTBs) and power toothbrushes (PTBs) are effective oral physiotherapy aids for plaque removal. End-rounded bristles are safer and reduce damage to oral tissues. Nylon bristles are more effective in plaque removal because the bristle is stiffer than natural bristles.

View Article and Find Full Text PDF

The framework presented in this article demonstrates strategies for a global approach to e-curricula in dental education by considering a collection of outcome assessment tools. By combining the outcomes for overall assessment, a global model for a pilot project that applies e-assessment tools to virtual learning environments (VLE), including haptics, is presented. Assessment strategies from two projects, HapTEL (Haptics in Technology Enhanced Learning) and UDENTE (Universal Dental E-learning), act as case-user studies that have helped develop the proposed global framework.

View Article and Find Full Text PDF

The study objective was to correlate wear between an in vitro method for simulating wear and in vivo wear of a posterior dental composite. Ten subjects (12 restorations) were selected from a five-year clinical study (University of North Carolina, School of Dentistry) that assessed wear of SureFil composite (Caulk, Dentsply). Subject casts were digitized and changes in volume and mean depth with time were calculated from the 3D digital models for contact and contact-free wear.

View Article and Find Full Text PDF

Objective: Review correlations of in vivo clinical performance with in vitro laboratory tests of restorative dental materials involving polymer-based matrices. Identify those factors interfering with the process.

Materials And Methods: An evidence-based dentistry approach was used to identify clinical trials, critical reviews, and meta-analyses involving correlations.

View Article and Find Full Text PDF

In 2007, new clinical criteria were approved by the FDI World Dental Federation and simultaneously published in three dental journals. The criteria were categorized into three groups: esthetic parameters (four criteria), functional parameters (six criteria), and biological parameters (six criteria). Each criterion can be expressed with five scores, three for acceptable and two for non-acceptable (one for reparable and one for replacement).

View Article and Find Full Text PDF

In 2007, new clinical criteria were approved by the FDI World Dental Federation and simultaneously published in three dental journals. The criteria were categorized into three groups: esthetic parameters (four criteria), functional parameters (six criteria) and biological parameters (six criteria). Each criterion can be expressed with five scores, three for acceptable and two for non-acceptable (one for reparable and one for replacement).

View Article and Find Full Text PDF

Objective: Adhesion or cohesion includes an adherend, adhesive, and intervening interface. Adhesive joints may include one or more interfaces. Adhesion science focuses on understanding the materials properties associated with formation of the interfaces, changes in the interfaces with time, and events associated with failure of the interfaces.

View Article and Find Full Text PDF

Background: Scientific advances in cariology in the past 150 years have led to the understanding that dental caries is a chronic, dietomicrobial, site-specific disease caused by a shift from protective factors favoring tooth remineralization to destructive factors leading to demineralization. Epidemiologic data indicate that caries has changed in the last century; it now is distributed unequally in the U.S.

View Article and Find Full Text PDF

Background: The authors conducted a study to evaluate the clinical performance of a dual-cured, three-step dentin adhesive (OptiBond Dual Cure, Kerr, a subsidiary of Sybron Dental Specialties, Orange, Calif.; no longer on the market) at 12 years.

Methods: The authors restored 100 noncarious cervical lesions without use of macromechanical retention or enamel bevels.

View Article and Find Full Text PDF

Purpose: An in vitro study was performed to assess the effect of different degrees of clinical reduction of zirconia abutments on the failure load of clinical assemblies.

Materials And Methods: Zirconia abutments (Y-TZP Ceramic Abutment, Astra Tech) were prepared with 0, 0.5, or 1 mm of external axial reduction starting 1 mm above the height-of-contour.

View Article and Find Full Text PDF

About 35 years ago, Ryge provided a practical approach to the evaluation of the clinical performance of restorative materials. This systematic approach was soon universally accepted. While that methodology has served us well, a large number of scientific methodologies and more detailed questions have arisen that require more rigor.

View Article and Find Full Text PDF