Background: The National Institute of Standards and Technology (NIST) has produced over 40 botanical dietary supplement Standard Reference Materials (SRMs) and reference materials (RMs) with values assigned for chemical markers and/or active compounds. Although environmental accumulation or inadvertent introduction of toxic elements (arsenic, cadmium, lead, and mercury) is a potential source of exposure in botanical dietary supplement products, the majority of the dietary supplement SRMs/RMs do not have values assigned for the four major toxic elements.
Objective: To determine As, Cd, Pb, and Hg content in the current inventory of NIST botanical dietary supplement SRMs/RMs.
Background: Dietary supplements derived from botanicals are commonly consumed and investigated in biomedical studies for their potential health benefits. Accurate identification and quantification of key chemical constituents from botanical ingredients is necessary for consistent product preparations and reproducible research results. Manufacturers need quantitative reference materials of the chemical constituents of interest to verify the content of ingredients and products.
View Article and Find Full Text PDFNinety archived human serum samples from the Vitamin D External Quality Assessment Scheme (DEQAS) were analyzed using a reference measurement procedure (RMP) based on isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS) for the determination of 24,25-dihydroxyvitamin D [24,25(OH)D]. These 24,25(OH)D results, in conjunction with concentration values assigned using RMPs for 25-hydroxyvitamin D [25(OH)D] and 25-hydroxyvitamin D [25(OH)D], provide a valuable resource for assessing the accuracy of measurements for 24,25(OH)D and for investigating the relationship between 24,25(OH)D and 25(OH)D. Results for 24,25(OH)D using the RMP were compared to DEQAS consensus values demonstrating that the consensus values were not sufficient to assess the accuracy of measurements among different laboratories and methods.
View Article and Find Full Text PDFThe US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels.
View Article and Find Full Text PDFThe majority of circulating 25-hydroxyvitamin D (25(OH)D) is protein bound and perhaps less available than the free fraction of 25(OH)D; therefore, researchers have proposed that the measurement of free 25(OH)D in human serum may be a better indicator of vitamin D health status than total 25(OH)D. The availability of a new enzyme-linked immunosorbent assay (ELISA) for the determination of free 25(OH)D provides a method for direct measurement of the low levels of non-protein bound 25(OH)D. As an initial step towards harmonization of measurements of free 25(OH)D, the ELISA was used to measure free 25(OH)D in three existing Standard Reference Materials (SRMs): SRM 972a Vitamin D Metabolites in Frozen Human Serum, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level), and SRM 1949 Frozen Prenatal Human Serum.
View Article and Find Full Text PDFCertified reference materials (CRMs) are routinely used by analytical chemists to validate new analytical methods and to demonstrate the quality of their quantitative measurements. Even though CRMs for trace element and trace organic analysis have been available and widely used for over 50 years, the majority of papers published in analytical chemistry journals do not mention the use of CRMs. What if analytical/bioanalytical chemistry journals required the use of CRMs to publish a paper? This feature article attempts to address this question by providing examples of recent papers that have made exceptional use of CRMs to validate new analytical methods and to describe novel, alternative uses of CRMs that provide new characterization of the CRM.
View Article and Find Full Text PDFAnalytical techniques for chemical analysis of oil, oil photochemical and biological transformation products, and dispersants and their biodegradation products benefited significantly from research following the 2010 (DWH) disaster. Crude oil and weathered-oil matrix reference materials were developed based on the Macondo well oil and characterized for polycyclic aromatic hydrocarbons, hopanes, and steranes for use to assure and improve the quality of analytical measurements in oil spill research. Advanced gas chromatography (GC) techniques such as comprehensive two-dimensional GC (GC × GC), pyrolysis GC with mass spectrometry (MS), and GC with tandem MS (GC-MS/MS) provide a greater understanding at the molecular level of composition and complexity of oil and weathering changes.
View Article and Find Full Text PDFBackground: In collaboration with the Office of Dietary Supplements at the National Institutes of Health, the National Institute of Standards and Technology issued a suite of botanical matrix reference materials (RMs) and Standard Reference Material® (SRM) for determination of isoflavones and toxic elements in kudzu dietary supplement ingredients.
Objective: RM 8650 Pueraria montana var. lobata (Kudzu) Rhizome, SRM 3268 Pueraria montana var.
Insufficient assessment of the identity and chemical composition of complex natural products, including botanicals, herbal remedies, and dietary supplements, hinders reproducible research and limits understanding mechanism(s) of action and health outcomes, which in turn impede improvements in clinical practice and advances in public health. This review describes available analytical resources and good methodological practices that support natural product characterization and strengthen the knowledge gained for designing and interpreting safety and efficacy investigations. The practice of validating analytical methods demonstrates that measurements of constituents of interest are reproducible and appropriate for the sample (e.
View Article and Find Full Text PDFAn interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D [25(OH)D], 25-hydroxyvitamin D [25(OH)D], 3-epi-25-hydroxyvitamin D [3-epi-25(OH)D], and 24R,25-dihydroxyvitamin D [24R,25(OH)D] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays.
View Article and Find Full Text PDFAn interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D (25(OH)D) and 25-hydroxyvitamin D (25(OH)D). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D, 25(OH)D, 3-epi-25-hydroxyvitamin D (3-epi-25(OH)D), and 24R,25-dihydroxyvitamin D (24R,25(OH)D) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays.
View Article and Find Full Text PDFDuring the past 40 years, the National Institute of Standards and Technology (NIST) has developed over 180 natural matrix Standard Reference Materials® (SRMs) for the determination of trace organic constituents in environmental, clinical, food, and dietary supplement matrices. A list of the Top Ten SRMs intended for organic analysis was identified based on selection criteria including analytical challenge to assign certified values, challenges in material preparation, novel matrices, longevity, widespread use, and unique design concept or intended use. The environmental matrix SRMs include air particulate matter, marine sediment, mussel tissue, and human serum with the focus on contaminants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).
View Article and Find Full Text PDFAn intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D (> 30 nmol/L), were assigned target values for 25(OH)D and 25(OH)D using reference measurement procedures (RMP).
View Article and Find Full Text PDFObjectives: Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy.
Methods: Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester.
The present study investigates the analytical potential of low-temperature photoluminescence spectroscopy for the analysis of seven phenanthrothiophenes with molecular mass 234 g mol. The studied PASHs include Phenanthro [1,2-b]thiophene, Phenanthro [2,1-b]thiophene, Phenanthro [2,3-b]thiophene, Phenanthro [3,2-b]thiophene, Phenanthro [3,4-b]thiophene, Phenanthro [4,3-b]thiophene and Phenanthro [9,10-b]thiophene. Excitation and emission spectra recorded from n-alkane solutions at room temperature, 77 K and 4.
View Article and Find Full Text PDFThe Dietary Supplement Label Database (DSLD) is sponsored by the Office of Dietary Supplements (ODS) and the National Library of Medicine (NLM). It provides a searchable, free database of the contents of ∼65,000 supplement labels. A companion database of analytically verified product labels [the Dietary Supplement Ingredient Database (DSID)] was created by ODS, NLM, and the USDA.
View Article and Find Full Text PDFSecondary organic aerosol (SOA) accounts for a significant fraction of particulate matter (PM) in the atmosphere. Source identification, including the SOA fraction, is critical for the effective management of air pollution. Molecular SOA markers (tracers) are key compounds allowing the source apportionment of SOA using different methodologies.
View Article and Find Full Text PDFFor over 40 years, food-matrix certified reference materials (CRMs) have been available for determination of trace element content, and a wide variety of materials are available from most producers of CRMs. However, the availability of food-matrix CRMs for organic nutrients has been more limited. The European Commission (EC) Bureau Communautaire de Référence (BCR) and the National Institute of Standards and Technology (NIST) introduced food-matrix CRMs with values assigned for vitamins and other organic nutrients such as fatty acids and carotenoids in the 1990s.
View Article and Find Full Text PDF