Introduction: Many military service members and civilians suffer from lower extremity trauma. Despite recent advancements in lower limb bracing technology, it remains unclear whether these newer advanced braces offer improved comfort and functionality compared to conventional options. The IDEO (Intrepid Dynamic Exoskeletal Orthosis), a type of "advanced" orthosis was developed to assist in maintaining high functional performance in patients who have experienced high-energy lower extremity trauma and underwent limb salvage surgeries.
View Article and Find Full Text PDFFoot-drop is one of the most diagnosed and physically limiting symptoms persons with multiple sclerosis (pwMS) experience. Clinicians prescribe ankle-foot orthosis (AFO) and functional electrical stimulation (FES) devices to help alleviate the effects of foot drop, but it is unclear how their clinical and functional gait improvements compare given the user's level of disability, type of multiple sclerosis, walking environment, or desired physical activity. The research questions explored were what is the current state of AFO and FES research for pwMS? What are the prevailing research trends? What definitive clinical and functional device comparisons exist for pwMS? eight databases were systematically searched for relevant literature published between 2009 and 2021.
View Article and Find Full Text PDFLife Sci Space Res (Amst)
August 2022
With long-term space flights being planned for the Moon and Mars, proper countermeasures must be taken to facilitate human health in microgravity environments. Exercise is a vital countermeasure used to prevent bone and muscle loss, among other health interests. Future exploration missions encourage creating an exercise device that is both compact and can be used to properly execute exercise by the astronauts.
View Article and Find Full Text PDFBackground: There are alternative transfemoral (TF) socket interface designs that have not been compared with the standard of care, ischial ramus containment (IRC). The interface directly affects performance.
Objectives: To compare 3 TF interface designs, IRC, dynamic socket (DS), and subischial (Sub-I), regarding gait, balance, mobility, and preference.
Background: The most crucial aspect of a prosthesis is the socket, as it will directly determine gait stability and quality. The current standard of care ischial ramus containment socket is reported to increase coronal stability through gait; however, socket discomfort is the primary complaint among prosthetic users.
Objectives: The purpose of this study is to compare ischial ramus containment to alternatives in the transfemoral amputee population.
Annu Int Conf IEEE Eng Med Biol Soc
July 2018
Our team developed a mobile wheelchair control kit designed to allow power wheelchair users the ability to maneuver their wheelchair without the need to manipulate a joystick with their hands. A smartphone and its internal accelerometer sensor was used to detect the vector of gravity, and thus detecting the pitch and roll. The wheelchair control system was tested with the phone attached in three mounting positions: hand held, hat and arm band and compared to the manipulation using the wheelchair joystick.
View Article and Find Full Text PDFThis study was a randomized crossover of stair ambulation of Transfemoral Amputees (TFAs) using the Genium and C-Leg prosthetic knees. TFAs typically have difficulty ascending and descending stairs, limiting community mobility. The objective of this study was to determine the relative efficacy of the Genium and C-Leg prostheses for stair ascent and descent, and their absolute efficacy relative to non-amputees.
View Article and Find Full Text PDFThe Continuous Scale-Physical Functional Performance-10 (CS-PFP-10) test consists of 10 standardized daily living tasks that evaluate overall physical functional performance and performance in five individual functional domains: upper body strength (UBS), upper body flexibility (UBF), lower body strength (LBS), balance and coordination (BAL), and endurance (END). This study sought to determine the concurrent validity of the CS-PFP-10 test and its functional domains that involve the lower extremities (LBS, BAL, or END) in comparison to measures that have established validity for use in persons with transfemoral amputation (TFA). Ten TFA patients functioning at K3 or higher (Medicare Functional Classification Level) completed the study.
View Article and Find Full Text PDFUse of the Genium microprocessor knee (MPK) system reportedly improves knee kinematics during walking and other functional tasks compared to other MPK systems. This improved kinematic pattern was observed when walking on different hill conditions and at different speeds. Given the improved kinematics associated with hill walking while using the Genium, a similar improvement in the symmetry of knee kinetics is also feasible.
View Article and Find Full Text PDFMicroprocessor prosthetic knees (MPKs) have advanced technologically, offering new features to decrease impairment and activity limitations for persons with transfemoral amputation (TFA). The Genium knee is functionally untested, and functional differences between it and intact knees are unknown. This study sought to determine whether Genium use improves functional performance compared with the C-Leg.
View Article and Find Full Text PDFCompared to non-microprocessor knees, the C-Leg microprocessor knee (MPK) is bioenergentically and economically more efficient and safer for transfemoral amputation (TFA) patients. The Genium MPK has demonstrated improvements in perceived function, knee kinematics, and physical functional performance compared to C-Leg. Clinical and health economic analyses have not been conducted with the Genium knee system.
View Article and Find Full Text PDFBackground: Approximately 683 persons engaged in military service experienced transtibial amputation (TTA) related to recent war in Iraq and Afghanistan. Military TTAs function at a level beyond basic ambulation. No empirical data demonstrate which higher functioning prosthetic feet maximize injured service personnel's ability to continue performing at a level commensurate with return to duty.
View Article and Find Full Text PDFThe choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to inform evidence-based clinical practice regarding prescription of these devices and training of users.
View Article and Find Full Text PDFBackground And Aim: Longer residual limb lengths provide an increased lever arm. Longer residual limbs may produce increased joint moments; the two may be correlated. These correlations have not been evaluated in transfemoral amputees during transitional movements.
View Article and Find Full Text PDFBackground: Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user.
View Article and Find Full Text PDFBackground: Typical upper limb prostheses may limit sports participation; therefore, specialized terminal devices are often needed. The purpose of this study was to evaluate the ability of transradial amputees to play golf using a specialized terminal device.
Case Description And Methods: Club head speed, X-factor, and elbow motion of two individuals with transradial amputations using an Eagle Golf terminal device were compared to a non-amputee during a golf swing.
Annu Int Conf IEEE Eng Med Biol Soc
September 2015
This paper reviews the variations in human upper body motion of subjects completing activities of daily living. This study was completed to serve as a reference to evaluate the quality of simulated of human motion. In this paper we define the variation in motion as the variation in subjects' parameters (link lengths), joint angles, and hand positions, for a given task.
View Article and Find Full Text PDFTransitional movements are a determinant of functional independence and have limited study in amputees. Microprocessor prosthetic knees' abilities to assist transfemoral amputees with sitting and standing have not been studied. Through cross-sectional study, 21 transfemoral amputees, divided into 3 groups of 7 by knee type (power knee, C-leg, Mauch SNS) and 7 non-amputee controls (n=28) performed sit to stand and stand to sit while kinematic and kinetic data were recorded.
View Article and Find Full Text PDFTo assist upper extremity amputees with achieving stable grasps of cylindrical tools, this article describes the development and testing of a prosthetic device for recreational kayak paddling. Initial development included participation of a non-amputee expert kayakist. Subsequent testing of the device used a pseudo-prosthesis for testing on a non-amputee subject, followed by qualitative feedback on the device from a unilateral transradial amputee.
View Article and Find Full Text PDFThis study examined the kinematic differences of a bilateral transradial amputee using myoelectric and body-powered prostheses during select activities of daily living. First in harness suspended, body powered then self-suspended externally powered prostheses, the subject's shoulder and elbow joint movements were calculated and compared while completing an elbow range of motion test, simulated drinking from an empty cup, and opening a door. In this case, body-powered prostheses allowed for greater range of elbow flexion but required more shoulder flexion to complete the tasks that required continuous grasp.
View Article and Find Full Text PDFClin Biomech (Bristol)
November 2008
Background: Recent studies have documented motions of the upper limbs of healthy subjects during activities of daily living. The aim of this study was to investigate compensatory motions of the upper extremity and torso during tasks for transradial prosthesis users and to determine if bracing simulates prosthesis use.
Methods: Seven transradial myoelectric prosthesis users and 10 non-amputee volunteers performed four common tasks.