Purpose: To evaluate the feasibility and accuracy of quantification of calcified coronary stenoses using virtual non-calcium (VNCa) images in coronary CT angiography (CCTA) with photon-counting detector (PCD) CT compared with quantitative coronary angiography (QCA).
Materials And Methods: This retrospective, institutional-review board approved study included consecutive patients with calcified coronary artery plaques undergoing CCTA with PCD-CT and invasive coronary angiography between July and December 2022. Virtual monoenergetic images (VMI) and VNCa images were reconstructed.
Preoperative evaluation of the mitral valve but also of tricuspid valve and right ventricular (RV) function is mandatory in primary mitral regurgitation (MR) secondary to mitral valve prolapse (MVP). Tricuspid annulus (TA) diameter plays a pivotal role in the surgical decision to perform preventive combined tricuspid valve annuloplasty. Cardiac magnetic resonance (CMR) is the gold standard for the assessment of RV size and function.
View Article and Find Full Text PDFBackground: Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently showed encouraging results. Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time consuming.
Aims: To investigate the accuracy and reproducibility of new automated fast 3D TTE software (HeartModel; Philips Healthcare, Andover, MA, USA) for the quantification of LV volumes and MR severity in patients with isolated degenerative primary MR; and to compare regurgitant volume (RV) obtained with 3D TTE with a cardiac magnetic resonance (CMR) reference.
Background: Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fraction (LVEF). Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time-consuming.
Aims: To evaluate the feasibility, accuracy and reproducibility of new fully automated fast 3D TTE software (HeartModel; Philips Healthcare, Andover, MA, USA) for quantification of LV volumes and LVEF in routine practice; to compare the 3D LV volumes and LVEF obtained with a cardiac magnetic resonance (CMR) reference; and to optimize automated default border settings with CMR as reference.
Background: Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context.
View Article and Find Full Text PDFBackground: The purpose of the study was to determine the long-term prognostic value of normal adenosine stress cardiac magnetic resonance imaging (CMR) in patients referred for evaluation of myocardial ischemia.
Methods: We reviewed 300 consecutive patients (age 65 ± 11 years, 74% male) with suspected or known coronary disease and normal wall motion who had undergone adenosine stress CMR negative for ischemia and scar. Most patients were at intermediate risk of coronary artery disease.
A paucity of data on outcome of coronary multislice computed tomography (CT) is available. The aim of this study was to assess the long-term follow-up of 64-slice CT in a homogenous patient group. In total 222 patients (136 men, 61%, 59 ± 11 years of age) with chest pain at intermediate risk of coronary artery disease (CAD) and no previous CAD underwent 64-slice CT.
View Article and Find Full Text PDF