Publications by authors named "Stephane Fromentin"

Background And Aims: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e.

View Article and Find Full Text PDF

This survey evaluated hypnosis practice in French centres in June 2020. The survey was sent via email to different rhythmology centres in France and responses from cardiologists and nurses were obtained. We present here the preliminary results of this survey.

View Article and Find Full Text PDF

Background: Remote monitoring (RM) can remotely detect atrial tachyarrhythmias (ATAs). The benefit of RM compared to conventional follow-up in the detection and management of ATA was assessed in recipients of dual-chamber pacemakers.

Methods: The multicenter randomized SETAM study enrolled 595 patients in sinus rhythm with a CHA DS -VASc score ≥2, without ATA history and untreated with antiarrhythmics and antithrombotics, randomly assigned to RM (RM-ON; n = 291) versus ambulatory follow-up (RM-OFF; n = 304) during 12.

View Article and Find Full Text PDF

Aim: Atrial flutter (AFL) ablation requires optimal periprocedural anticoagulation in order to minimize thromboembolic events/bleeding risk. This study describes the characteristics of patients receiving new oral anticoagulants before AFL ablation and assesses complications.

Methods: This multicenter, retrospective study reports ischemic and hemorrhagic predischarge, postprocedural complications.

View Article and Find Full Text PDF

Purpose: Patients undergoing left atrial ablation require transseptal puncture, which can be challenging, even for experienced physicians. This study compared the efficacy and safety of radiofrequency (RF) energy transseptal punctures to conventional approach.

Methods: Patients requiring transseptal puncture for left atrial access were included using either conventional approach or the NRG™ RF transseptal needle as first attempt.

View Article and Find Full Text PDF

Background: In patients with common atrial flutter (CAF), radiofrequency ablation (RFA) causes discomfort. Patients undergoing RFA often feel pain which is difficult to control as the mechanisms are unclear.

Hypothesis: Inhaled nitrous oxide (N2O) is a potent sedative-analgesic-anxiolytic agent that may relieve anxiety and discomfort during CAF ablation.

View Article and Find Full Text PDF

Aims: Cavo-tricuspid isthmus (CTI) radiofrequency (RF) ablation is a curative therapy for common atrial flutter (AFl), but is associated with a recurrence rate of 5-26%. Although complete bidirectional conduction block is usually achieved, the recurrence of AF is due to recovered conducting isthmus tissue through which activation wavefronts pass. We evaluated a simple and efficient electrophysiological strategy, which pinpoints the ablation target.

View Article and Find Full Text PDF

Background: A complete line of block (CLOB) in the cavotricuspid isthmus (CTI) is the endpoint of typical atrial flutter ablation. Before CTI block is obtained, a progressive CTI conduction delay due to an incomplete line of block (InLOB) can be difficult to distinguish from CLOB. The purpose of this study was to assess a new simple approach based on the changes in atrio-ventricular (AV) conduction delays during septal and lateral right atrial pacing, to distinguish a CLOB from an InLOB during typical atrial flutter (AFL) ablation.

View Article and Find Full Text PDF