: Despite the preferred application of arterial conduits, the greater saphenous vein (SV) remains indispensable for coronary bypass grafting (CABG), especially in multi-vessel coronary artery disease (CAD). The objective of the present work was to address the role of mechanical forces in the activation of maladaptive vein bypass remodeling, a process determining progressive occlusion and recurrence of ischemic heart disease. : We employed a custom bioreactor to mimic the coronary shear and wall mechanics in human SV vascular conduits and reproduce experimentally the biomechanical conditions of coronary grafting and analyzed vein remodeling process by histology, histochemistry and immunofluorescence.
View Article and Find Full Text PDFBackground Aims: The Pall Celeris system is a filtration-based point-of-care device designed to obtain a high concentrate of peripheral blood total nucleated cells (PB-TNCs). We have characterized the Pall Celeris-derived TNCs for their in vitro and in vivo angiogenic potency.
Methods: PB-TNCs isolated from healthy donors were characterized through the use of flow cytometry and functional assays, aiming to assess migratory capacity, ability to form capillary-like structures, endothelial trans-differentiation and paracrine factor secretion.
Background: Prospective single-arm study, aimed at evaluating safety and effectiveness at 12 and 24 months of the paclitaxel-eluting nitinol stent (Zilver PTX), and focused in particular on the treatment of complex lesions and/or diabetic patients.
Methods: Between May 2010 and March 2012, 67 patients (78% males) were treated by Zilver PTX, because of stenosis or occlusions of the superficial femoral artery in one of two centers. The mean age of patients was 70.
Asian Cardiovasc Thorac Ann
June 2013
A 79-year-old man underwent coronary artery bypass grafting and ascending aorta prosthetic replacement for aneurysm at our Institution. His postoperative course was characterized by rapid onset of hypotension and anemia. Re-exploration found no surgical source of bleeding.
View Article and Find Full Text PDFInt J Artif Organs
December 2012
We report on a patient with a femoropopliteal bypass infected by Kytococcus sedentarius. Treatment consisted of resection of the infected prosthesis with homograft substitution and antibiotic therapy started postoperatively. At 6 months followup, the patient showed no signs of infection and results of laboratory findings were normal.
View Article and Find Full Text PDFObjectives: Thoracic endovascular aneurysm repair (TEVAR) is an appealing alternative to the standard surgical approach, but requires rigorous radiological follow-up. The cumulative radiation exposure (RE) of patients undergoing TEVAR-including pre-operative workup, the procedure and subsequent follow-up computed tomography (CT) imaging-has not previously been investigated.
Methods: From August 2003 to February 2011, 48 patients underwent TEVAR at our institution.
Surgical treatment of abdominal aortic aneurysm after previous pneumonectomy is a challenge because of the impaired respiratory function and increased surgical risks. Endovascular aneurysm repair in anatomically suited high-surgical-risk patients offers excellent short-term results and provides good protection from aneurysm-related death. In this article, we report a successful endovascular aneurysm repair of an infrarenal aortic aneurysm in a patient with past left pneumonectomy.
View Article and Find Full Text PDFObjective: To minimize paraplegia during thoracoabdominal aortic aneurysm repair, the concept of the collateral network was developed. That is, spinal cord perfusion is provided by an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural space and in the paravertebral muscles, including intercostal and lumbar segmental as well as subclavian and hypogastric arteries.
Methods: Collateral network pressure was measured with a catheter in the distal end of a ligated segmental artery in pigs and human beings.
Background: Bicuspid aortic valves (BAV) are frequently associated with root/ascending aorta dilatation, but there is controversy regarding when to operate to prevent dissection of a dilated aorta associated with a well-functioning BAV.
Methods: From 1988 through 2008, 158 patients (mean age: 56 ± 13.5 years) with a dilated ascending aorta (AA) and a well-functioning BAV were referred to our institution.
Background: Endovascular repair of descending thoracic and thoracoabdominal aortic aneurysms is an appealing alternative to the standard surgical approach, but precludes revascularization of segmental arteries (SAs). For safer surgical and endovascular repairs, an accurate prediction of the risk of paraplegia in relation to the extent of SA sacrifice is needed.
Methods: From January 1994 to October 2008, 609 patients (mean age, 63 ± 14 years) underwent surgical descending thoracic or thoracoabdominal aortic aneurysm repair without SA reimplantation.
Background: In a pig model, we compared spinal cord injury after extensive segmental artery (SA) sacrifice in a single stage with recovery after a two-stage procedure: lumbar artery followed by thoracic SA sacrifice.
Methods: Twenty juvenile Yorkshire pigs were randomly assigned to undergo extensive SA sacrifice at 32 degrees C in a single operation (group 1, n = 10), or thoracic SA ligation 7 days after lumbar artery sacrifice (group 2, n = 10). Spinal cord perfusion pressure (SCPP) was monitored using a catheter placed in the distal stump of L1.
Objective: Paraplegia remains a devastating, and still too frequent, complication after repair of extensive thoracoabdominal aortic aneurysms. Strategies to prevent ischemic spinal cord damage after extensive segmental artery sacrifice-or occlusion, essential for endovascular repair-are still evolving.
Methods: Ninety patients who underwent extensive segmental artery sacrifice (median, 13; range, 9-15) during open surgical repair from June 1994 to December 2007 were reviewed retrospectively.
Background: The optimal treatment of chronic distal aortic dissection remains controversial, with endovascular stent-graft techniques challenging traditional surgery.
Methods: From January 1994 to April 2007, 104 patients (82 male, median age 60.5 years) with chronic distal aortic dissection underwent surgical repair, 0 to 21 years after initial diagnosis of acute type A or B dissection (median 2.
Iatrogenic acute type B dissection is a rare complication of intraaortic balloon pumping. Delayed visceral and spinal cord malperfusion can occur for distal progression of the dissection or relative hypotension. Cerebrospinal fluid drainage and percutaneous balloon fenestration provide a safe and effective method for managing ischemic complications.
View Article and Find Full Text PDFBackground: Reoperative descending thoracic aorta (DTA) or thoracoabdominal aortic aneurysm (TAAA) surgery is a challenge because of increased risk of lung injury and diffuse bleeding.
Methods: Sixty patients (34 male, mean age 54.4 years) underwent redo thoracotomy for DTA (22 patients) or extended thoracoabdominal incision for reoperative TAAA (38 patients) from March 1988 to June 2007, after 1.
Eur J Cardiothorac Surg
December 2009
Objective: To shorten cooling/rewarming associated with hypothermic neuroprotection strategies during complex aortic arch surgery, selective cerebral perfusion (SCP) at 28 degrees C has recently been advocated, although its safe limits - especially with regard to the ischaemic tolerance of the spinal cord - have not been systematically examined.
Methods: Twenty juvenile Yorkshire pigs (30.3+/-2.
Background: Although maintenance of adequate spinal cord perfusion pressure (SCPP) by the paraspinal collateral network is critical to the success of surgical and endovascular repair of descending thoracic and thoracoabdominal aortic aneurysms, direct monitoring of SCPP has not previously been described.
Methods: A catheter was inserted into the distal end of a ligated thoracic segmental artery (SA) (T6 to L1) in 13 patients, 7 of whom underwent descending thoracic and thoracoabdominal aortic aneurysm repair using deep hypothermic circulatory arrest. Spinal cord perfusion pressure was recorded from this catheter before, during, and after serial SA sacrifice, in pairs, from T3 through L4, at 32 degrees C.
Here we report a rare case of a 74-year-old man with a pseudoaneurysm of the anterior tibial artery and a concomitant arteriovenous fistula (AVF). The patient was admitted because of increasing pain following the formation of a large mass located in the anterior mid-portion of the calf after a moderate non-penetrating blunt trauma. A polytetrafluoroethylene-covered stent was placed over the origin of the pseudoaneurysm, with complete exclusion of the pseudoaneurysm and disappearance of the AVF.
View Article and Find Full Text PDF