Current treatments of aortic aneurysm include surgical or endovascular, respectively, anatomical or functional, substitution of the aneurysm tract; however, with these methods, perfusion of at least some collateral branches cannot be fully restored, leading to the risk of paraplegia. We present a novel endovascular "net" prosthesis to strengthen the aortic wall while preserving perfusion of collateral branches. This consists of a polyester mesh "net"-layered conduit in a variable cylindrical shape, which is personalized based on patient computed tomography scan images, and is defined by circular crossing spirals of a thin nitinol wire.
View Article and Find Full Text PDFParaplegia in aortic surgery is due to its impact on spinal cord perfusion whose hemodynamic patterns (SCPHP) are not clearly defined. Detailed morphological analysis of vascular network and collateral network modifications within Monro-Kellie postulate due to the fixed theca confines was performed to identify SCPHP. SCPHP may begin with intraspinal "backflow" (I-BF), that is, hemorrhage from anterior and posterior spinal arteries, backward via the connected anterior and posterior radicular medullary arteries, through the increasing diameter and decreasing resistance of segmental arteries (SAs), off their aortic orifices outside vascular network at 0 operative field pressure.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
February 2010
In past years, we developed expandable devices (type I and II) for sutureless aortic anastomosis. We have now further modified the device (type III) incorporating a second expandable ring, external to the main one, which can be operated contrariwise in such a way that the aortic wall (i.e.
View Article and Find Full Text PDFAsian Cardiovasc Thorac Ann
March 2005
We report a case of primary synovial sarcoma of the lung. The patient was a 32-year-old male who presented with a mass in the right hemithorax invading the peritoneal cavity. The neoplasm was resected through a thoracic-abdominal approach.
View Article and Find Full Text PDFTo reduce the time needed for clamping or circulatory arrest (or both) during substitution of a prosthesis for the thoracic aorta, we developed an expandable device that can be used with any commercially available prosthetic graft to enable sutureless aortic anastomosis. Improvements upon a previous version of the device include the use of nickel-titanium alloy (Nitinol) instead of stainless steel. This, together with an improved wire-looping design, now enables continuous control of diameter, even when the device is in contact with blood.
View Article and Find Full Text PDF