Purpose: Scars and abnormal electrograms may significantly differ according to the activation wavefront. We propose a new fast technique for reliable comparison between sinus rhythm and ventricular pacing using a single map acquisition and the Rhythmia™ 3D mapping system.
Methods: A special programming of the external stimulator was assuring full stable regular paced-beat bigeminy during spontaneous rhythm.
Objectives: This study sought to identify atrial tachycardia (AT) demonstrating atrial activation duration (AAD) lasting longer than the length of the tachycardia cycle (TCL); to assess AT prevalence; and to evaluate the mechanisms and characteristics associated with these AT episodes by using the Rhythmia system (Boston Scientific, Marlborough, Massachusetts).
Background: Ultra-high-density mapping allows very accurate characterization of mechanisms involved in AT. Some complex patterns may involve AAD which is longer than the tachycardia cycle length (TCL) which makes maps difficult to interpret.
Ultra-high-density mapping allows very accurate characterization of circuits/mechanisms in atrial tachycardia (AT). Whether these advantages will translate into a better procedural or long-term clinical outcome is unknown. Sixty consecutive AT ablation procedures using ultra-high-density mapping (Rhythmia™, group 1) were retrospectively compared to 60 consecutive procedures using standard high-density mapping (Carto/NavX™, group 2) (total 209 AT, 79% left AT).
View Article and Find Full Text PDFPacing Clin Electrophysiol
November 2018
Diverging channels of activation may be observed in some ventricular tachycardia (VT) using ultra-high-density mapping. We present here cases of such diverging activation patterns as observed from 60 consecutive VT activation maps using the Rhythmia system™ (Boston Scientific, Marlborough, MA, USA). Diverging directions of activation in the same area with "crossroads" or "flyover" pattern can be traced, implying recording of independent multilayer channels.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
May 2017
Inappropriate sinus tachycardia (IST) is an incompletely understood condition associating unexpectedly fast sinus rates and debilitating symptoms whose management by sinus node modification/ablation demonstrated limited long-term success. We report about a case of IST who underwent two RF procedures using high density mapping system, highlighting some possibly specific features and discussing potential mechanisms.
View Article and Find Full Text PDFHerein, we report a 47-year-old woman with ischemic cardiomyopathy who underwent ablation therapy due to an electrical storm without any triggers. The voltage mapping in sinus rhythm with the Rhythmia system and Orion catheter displayed several LAVAs in and around the anteroapical scar area. Although the patient did not tolerate the induced clinical ventricular tachycardia, which was reproductively induced, 35-second-mapping in the scar zone with the Orion catheter demonstrated the VT circuit with the critical isthmus.
View Article and Find Full Text PDF