Publications by authors named "Stefan Tenbohlen"

Ultrahigh-frequency (UHF) sensing is one of the most promising techniques for assessing the quality of power transformer insulation systems due to its capability to identify failures like partial discharges (PDs) by detecting the emitted UHF signals. However, there are still uncertainties regarding the frequency range that should be evaluated in measurements. For example, most publications have stated that UHF emissions range up to 3 GHz.

View Article and Find Full Text PDF

The accurate measurement and the investigation of electromagnetic transients are becoming more important, especially with the increasing integration of renewable energy sources into the power grid. These sources introduce new transient phenomena due to the extensive use of power electronics. To achieve this, the measurement devices must have a broadband response capable of measuring fast transients.

View Article and Find Full Text PDF

The introduction of artificial intelligence (AI) to ultra-high-frequency (UHF) partial discharge (PD) monitoring systems in power transformers for the localization of PD sources can help create a robust and reliable system with high usability and precision. However, training the AI with experimental data or data from electromagnetic simulation is costly and time-consuming. Furthermore, electromagnetic simulations often calculate more data than needed, whereas, for localization, the signal time-of-flight information is the most important.

View Article and Find Full Text PDF

Ultra-high frequency (UHF) partial discharge (PD) measurements in power transformers are becoming popular because of the advantages of the method. Therefore, it is necessary to improve the basic understanding of the propagation of signals inside the transformer tank and the factors that influence the sensitivity of the measurement. Since the winding represents a major obstacle to the propagation of the UHF signals, it is necessary to study the effect of winding design on signal propagation.

View Article and Find Full Text PDF

Diagnoses of power transformers by partial discharge (PD) measurement are effective to prevent dielectric failures of the apparatus. Ultra-high frequency (UHF) method has recently received attention due to its various advantages, such as the robustness against external noise and the capability of PD localization. However, electromagnetic (EM) waves radiated from PD tend to suffer attenuation before arriving at UHF sensors, because active part of the transformer disturbs the EM wave propagation.

View Article and Find Full Text PDF