Close vital signs monitoring is crucial for the clinical management of patients with dengue. We investigated performance of a non-invasive wearable utilising photoplethysmography (PPG), to provide real-time risk prediction in hospitalised individuals. We performed a prospective observational clinical study in Vietnam between January 2020 and October 2022: 153 patients were included in analyses, providing 1353 h of PPG data.
View Article and Find Full Text PDFBackground: Dengue epidemics impose considerable strain on healthcare resources. Real-time continuous and non-invasive monitoring of patients admitted to the hospital could lead to improved care and outcomes. We evaluated the performance of a commercially available wearable (SmartCare) utilising photoplethysmography (PPG) to stratify clinical risk for a cohort of hospitalised patients with dengue in Vietnam.
View Article and Find Full Text PDFProblem: Direct application of digital health technologies from high-income settings to low- and middle-income countries may be inappropriate due to challenges around data availability, implementation and regulation. Hence different approaches are needed.
Approach: Within the Viet Nam ICU Translational Applications Laboratory project, since 2018 we have been developing a wearable device for individual patient monitoring and a clinical assessment tool to improve dengue disease management.
IEEE Trans Biomed Circuits Syst
April 2023
This article presents a novel PPG acquisition platform capable of synchronous multi-wavelength signal acquisition from two measurement locations with up to 4 independent wavelengths from each in parallel. The platform is fully configurable and operates at 1ksps, accommodating a wide variety of transmitters and detectors to serve as both a research tool for experimentation and a clinical tool for disease monitoring. The sensing probes presented in this work acquire 4 PPG channels from the wrist and 4 PPG channels from the fingertip, with wavelengths such that surrogates for pulse wave velocity and haematocrit can be extracted.
View Article and Find Full Text PDFElectrocardiogram (ECG) and photoplethysmogram (PPG) are commonly used to determine the vital signs of heart rate, respiratory rate, and oxygen saturation in patient monitoring. In addition to simple observation of those summarized indexes, waveform signals can be analyzed to provide deeper insights into disease pathophysiology and support clinical decisions. Such data, generated from continuous patient monitoring from both conventional bedside and low-cost wearable monitors, are increasingly accessible.
View Article and Find Full Text PDF