Diffuse correlation spectroscopy (DCS) is a powerful tool for assessing microvascular hemodynamic in deep tissues. Recent advances in sensors, lasers, and deep learning have further boosted the development of new DCS methods. However, newcomers might feel overwhelmed, not only by the already-complex DCS theoretical framework but also by the broad range of component options and system architectures.
View Article and Find Full Text PDFDiffuse correlation spectroscopy (DCS) is an optical method that offers non-invasive assessment of blood flow in tissue through the analysis of intensity fluctuations in diffusely backscattered coherent light. The non-invasive nature of the technique has enabled several clinical applications for deep tissue blood flow measurements, including cerebral blood flow monitoring as well as tumor blood flow mapping. While a promising technique, in measurement configurations targeting deep tissue hemodynamics, the standard DCS implementations suffer from insufficient signal-to-noise ratio (SNR), depth sensitivity, and sampling rate, limiting their utility.
View Article and Find Full Text PDFSpeckle contrast optical spectroscopy (SCOS) is an emerging camera-based technique that can measure human cerebral blood flow (CBF) with high signal-to-noise ratio (SNR). At low photon flux levels typically encountered in human CBF measurements, camera noise and nonidealities could significantly impact SCOS measurement SNR and accuracy. Thus, a guide for characterizing, selecting, and optimizing a camera for SCOS measurements is crucial for the development of next-generation optical devices for monitoring human CBF and brain function.
View Article and Find Full Text PDFSignificance: Achieving pathologic complete response (pCR) after neoadjuvant chemotherapy (NACT) is a significant predictor of increased likelihood of survival in breast cancer patients. Early prediction of pCR is of high clinical value as it could allow personalized adjustment of treatment regimens in non-responding patients for improved outcomes.
Aim: We aim to assess the association between hemoglobin-based functional imaging biomarkers derived from diffuse optical tomography (DOT) and the pathological outcome represented by pCR at different timepoints along the course of NACT.
Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique.
View Article and Find Full Text PDFSignificance: Monte Carlo (MC) simulations are currently the gold standard in the near-infrared and diffuse correlation spectroscopy (NIRS/DCS) communities for generating light transport paths through tissue. However, realistic and diverse models that capture complex tissue layers are not easily available to all; moreover, manually placing optodes on such models can be tedious and time consuming. Such limitations may hinder the adoption of representative models for basic simulations and the use of these models for large-scale simulations, e.
View Article and Find Full Text PDFSignificance: Combining near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) allows for quantifying cerebral blood volume, flow, and oxygenation changes continuously and non-invasively. As recently shown, the DCS pulsatile cerebral blood flow index () can be used to quantify critical closing pressure (CrCP) and cerebrovascular resistance ().
Aim: Although current DCS technology allows for reliable monitoring of the slow hemodynamic changes, resolving pulsatile blood flow at large source-detector separations, which is needed to ensure cerebral sensitivity, is challenging because of its low signal-to-noise ratio (SNR).
Diffuse correlation spectroscopy (DCS) is an optical technique that can be used to characterize blood flow in tissue. The measurement of cerebral hemodynamics has arisen as a promising use case for DCS, though traditional implementations of DCS exhibit suboptimal signal-to-noise ratio (SNR) and cerebral sensitivity to make robust measurements of cerebral blood flow in adults. In this work, we present long wavelength, interferometric DCS (LW-iDCS), which combines the use of a longer illumination wavelength (1064 nm), multi-speckle, and interferometric detection, to improve both cerebral sensitivity and SNR.
View Article and Find Full Text PDFIEEE Trans Med Imaging
August 2023
Near-infrared diffuse optical tomography (DOT) is a promising functional modality for breast cancer imaging; however, the clinical translation of DOT is hampered by technical limitations. Specifically, conventional finite element method (FEM)-based optical image reconstruction approaches are time-consuming and ineffective in recovering full lesion contrast. To address this, we developed a deep learning-based reconstruction model (FDU-Net) comprised of a Fully connected subnet, followed by a convolutional encoder-Decoder subnet, and a U-Net for fast, end-to-end 3D DOT image reconstruction.
View Article and Find Full Text PDFDiffuse correlation spectroscopy (DCS) has emerged as a versatile, noninvasive method for deep tissue perfusion assessment using near-infrared light. A broad class of applications is being pursued in neuromonitoring and beyond. However, technical limitations of the technology as originally implemented remain as barriers to wider adoption.
View Article and Find Full Text PDFNear-infrared diffuse optical tomography (DOT) has the potential to improve the accuracy of breast cancer diagnosis and aid in monitoring the response of breast tumors to chemotherapy by providing hemoglobin-based functional imaging. The use of structural lesion priors derived from clinical breast imaging methods, such as mammography, can improve recovery of tumor optical contrast; however, accurate lesion prior placement is essential to take full advantage of prior-guided DOT image reconstruction. Simultaneous optical and anatomical imaging may not always be possible or desired, which can make the accurate registration of the lesion prior challenging.
View Article and Find Full Text PDFThis report is the second part of a comprehensive two-part series aimed at reviewing an extensive and diverse toolkit of novel methods to explore brain health and function. While the first report focused on neurophotonic tools mostly applicable to animal studies, here, we highlight optical spectroscopy and imaging methods relevant to noninvasive human brain studies. We outline current state-of-the-art technologies and software advances, explore the most recent impact of these technologies on neuroscience and clinical applications, identify the areas where innovation is needed, and provide an outlook for the future directions.
View Article and Find Full Text PDFTime-domain diffuse correlation spectroscopy (TD-DCS) offers a novel approach to high-spatial resolution functional brain imaging based on the direct quantification of cerebral blood flow (CBF) changes in response to neural activity. However, the signal-to-noise ratio (SNR) offered by previous TD-DCS instruments remains a challenge to achieving the high temporal resolution needed to resolve perfusion changes during functional measurements. Here we present a next-generation optimized functional TD-DCS system that combines a custom 1,064 nm pulse-shaped, quasi transform-limited, amplified laser source with a high-resolution time-tagging system and superconducting nanowire single-photon detectors (SNSPDs).
View Article and Find Full Text PDFCurrently, there is great interest in making neuroimaging widely accessible and thus expanding the sampling population for better understanding and preventing diseases. The use of wearable health devices has skyrocketed in recent years, allowing continuous assessment of physiological parameters in patients and research cohorts. While most health wearables monitor the heart, lungs and skeletal muscles, devices targeting the brain are currently lacking.
View Article and Find Full Text PDFBackground: Absolute quantification of metabolites in MR spectroscopic imaging (MRSI) requires a stable reference signal of known concentration. The Electronic REference To access In vivo Concentrations (ERETIC) has shown great promise but has not been applied in patients and 3D MRSI. ERETIC hardware has not been integrated with receive arrays due to technical challenges, such as coil combination and unwanted coupling between multiple ERETIC and receive channels, for which we developed mitigation strategies.
View Article and Find Full Text PDFObjective: Diffuse correlation spectroscopy (DCS) is an optical technique that allows for the non-invasive measurement of blood flow. Recent work has shown that utilizing longer wavelengths beyond the traditional NIR range provides a significant improvement to signal-to-noise ratio (SNR). However, current detectors both sensitive to longer wavelengths and suitable for clinical applications (InGaAs/InP SPADs) suffer from suboptimal afterpulsing and dark noise characteristics.
View Article and Find Full Text PDFThe ability of diffuse correlation spectroscopy (DCS) to measure cerebral blood flow (CBF) in humans is hindered by the low signal-to-noise ratio (SNR) of the method. This limits the high acquisition rates needed to resolve dynamic flow changes and to optimally filter out large pulsatile oscillations and prevents the use of large source-detector separations ( ), which are needed to achieve adequate brain sensitivity in most adult subjects. To substantially improve SNR, we have built a DCS device that operates at 1064 nm and uses superconducting nanowire single-photon detectors (SNSPD).
View Article and Find Full Text PDFObjectives: Real-time noninvasive monitoring of cerebral blood flow (CBF) during surgery is key to reducing mortality rates associated with adult cardiac surgeries requiring hypothermic circulatory arrest (HCA). We explored a method to monitor cerebral blood flow during different brain protection techniques using diffuse correlation spectroscopy (DCS), a noninvasive optical technique which, combined with frequency-domain near-infrared spectroscopy (FDNIRS), also provides a measure of oxygen metabolism.
Methods: We used DCS in combination with FDNIRS to simultaneously measure hemoglobin oxygen saturation (SO), an index of cerebral blood flow (CBF), and an index of cerebral metabolic rate of oxygen (CMRO) in 12 patients undergoing cardiac surgery with HCA.
Contamination of diffuse correlation spectroscopy (DCS) measurements of cerebral blood flow (CBF) due to systemic physiology remains a significant challenge in the clinical translation of DCS for neuromonitoring. Tunable, multi-layer Monte Carlo-based (MC) light transport models have the potential to remove extracerebral flow cross-talk in cerebral blood flow index ( ) estimates. We explore the effectiveness of MC DCS models in recovering accurate changes in the presence of strong systemic physiology variations during a hypercapnia maneuver.
View Article and Find Full Text PDFStudying tissue hemodynamics following breast compression has the potential to reveal new contrast mechanisms for evaluating breast cancer. However, how compression will be distributed and, consequently, how hemodynamics will be altered inside the compressed breast remain unclear. To explore the effect of compression, 12 healthy volunteers were studied by applying a step compression increase (4.
View Article and Find Full Text PDF