Background: A multidisciplinary heart team (HT) approach to patients with complex coronary artery disease has a class IB recommendation, yet there are limited data on adherence to HT treatment recommendations and long-term clinical follow-up. The objective of this study was to assess adherence rates to HT recommendations and assess long-term mortality rates among patients with complex CAD.
Methods And Results: Six hundred eighty-four sequential HT cases for complex coronary artery disease from January 2015 to May 2017 were reviewed.
Background: Cardiologists performing coronary angiography (CA) and percutaneous coronary intervention (PCI) are at risk of health problems related to chronic occupational radiation exposure. Unlike during CA and PCI, physician radiation exposure during right heart catheterization (RHC) and endomyocardial biopsy (EMB) has not been adequately studied. The objective of this study was to assess physicians' radiation doses during RHC with and without EMB and compare them to those of CA and PCI.
View Article and Find Full Text PDFImportance: Transesophageal echocardiography during percutaneous left atrial appendage closure (LAAO) and transcatheter edge-to-edge mitral valve repair (TEER) require an interventional echocardiographer to stand near the radiation source and patient, the primary source of scatter radiation. Despite previous work demonstrating high radiation exposure for interventional cardiologists performing percutaneous coronary and structural heart interventions, similar data for interventional echocardiographers are lacking.
Objective: To assess whether interventional echocardiographers are exposed to greater radiation doses than interventional cardiologists and sonographers during structural heart procedures.
Objective: This study was performed to investigate the efficacy and safety of robotic diagnostic coronary angiography.
Background: Robotic percutaneous coronary intervention is associated with marked reductions in physician radiation exposure. Development of robotic diagnostic coronary angiography might similarly impact occupational safety.
Fewer ST-elevation myocardial infarctions (STEMIs) presentations and increased delays in care occurred during the COVID-19 pandemic in urban areas. Whether these associations occurred in a more rural population has not been previously reported. Our objective was to evaluate the impact of COVID-19 on time-to-presentation for STEMI in rural locations.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
March 2022
Objective: This study was performed to evaluate physician radiation doses with the use of a suspended lead suit.
Background: Interventional cardiologists face substantial occupational risks from chronic radiation exposure and wearing heavy lead aprons.
Methods: Head-level physician radiation doses, collected using real-time dosimeters during consecutive coronary angiography procedures, were compared with the use of a suspended lead suit versus conventional lead aprons.
Background: In acute ischaemic stroke, endovascular thrombectomy (ET) significantly reduces disability compared with thrombolytic therapy, but access to ET is currently limited. Leveraging telerobotic technology to disseminate neurosurgical expertise could increase access to ET. This proof-of-concept evaluation was performed to determine whether remote robotic ET (RRET), wherein an offsite neurosurgeon and an onsite interventional cardiologist collaboratively use telerobotics to perform ET, is technically feasible.
View Article and Find Full Text PDFBackground And Aims: We aimed to characterize the spatial proximity of plaque destabilizing features local endothelial shear stress (ESS), minimal luminal area (MLA), plaque burden (PB), and near-infrared spectroscopy (NIRS) lipid signal in high- vs. low-risk plaques.
Methods: Coronary arteries imaged with angiography and NIRS-intravascular ultrasound (IVUS) underwent 3D reconstruction and computational fluid dynamics calculations of local ESS.
Background: Patient BMI is associated with radiation doses received by interventional cardiologists, yet the association between patient BMI and nurse radiation doses is unknown. This study evaluated the association between patient body mass index (BMI) and nurse radiation doses during coronary angiography.
Methods: Nurse radiation doses were collected by real-time dosimeters during consecutive coronary angiography procedures and are reported as the personal dose equivalent (H10).
Catheter Cardiovasc Interv
February 2021
Objectives: This study was conducted to evaluate the association of geographic distance with robotic telestenting performance by comparing performance measures in transcontinental and regional pre-clinical models of telestenting.
Background: Robotic telestenting, in which percutaneous coronary intervention (PCI) is performed on a remotely located patient, might improve PCI access, but has not been attempted over vast distances likely required to reach many underserved regions.
Methods: Telestenting performance was compared in regional (Boston to New York [206 miles]) and transcontinental (Boston to San Francisco [3,085 miles]) ex vivo models of telestenting, wherein a physician in Boston attempted robotic PCI on endovascular simulators in New York and San Francisco, respectively.
Objective: This study evaluated the impact of network latency on telestenting performance.
Background: The feasibility of long-distance robotic telestenting was recently demonstrated, yet the impact of network performance on telestenting remains unknown.
Methods: Ex vivo and in vivo telestenting models were constructed by connecting a robotic drive over a wired network to a robotic control system up to 103 miles away.
Circ Cardiovasc Interv
January 2019
Background: Consistent with the increasing prevalence of obesity in the general population, obesity has become more prevalent among patients undergoing cardiac catheterization. This study evaluated the association between patient body mass index (BMI) and physician radiation dose during coronary angiography.
Methods And Results: Real-time radiation exposure data were collected during consecutive coronary angiography procedures.
Background: The impact of patient obesity on scrub technologist radiation dose during coronary angiography has not been adequately studied.
Methods: Real-time radiation exposure data were prospectively collected during consecutive coronary angiography cases. Patient radiation dose was estimated by dose area product (DAP).
Objectives: This study was performed to determine if the use of an accessory lead shield is associated with a reduction in radiation exposure among staff members during cardiac catheterization.
Background: Accessory lead shields that protect physicians from scatter radiation are standard in many catheterization laboratories, yet similar shielding for staff members is not commonplace.
Methods: Real-time radiation exposure data were prospectively collected among nurses and technologists during 764 consecutive catheterizations.
Background: This study sought to determine the frequency of large lipid-rich plaques (LRP) in the coronary arteries of individuals with high coronary artery calcium scores (CACS) and to determine whether the CACS correlates with coronary lipid burden.
Methods And Results: Combined near-infrared spectroscopy and intravascular ultrasound was performed in 57 vessels in 20 asymptomatic individuals (90% on statins) with no prior history of coronary artery disease who had a screening CACS ≥300 Agatston units. Among 268 10-mm coronary segments, near-infrared spectroscopy images were analyzed for LRP, defined as a bright yellow block on the near-infrared spectroscopy block chemogram.
Aims: The present study explores the feasibility of telestenting, wherein a physician operator performs stenting on a patient in a separate physical location using a combination of robotics and telecommunications.
Methods And Results: Patients undergoing robotic stenting were eligible for inclusion. All manipulations of guidewires, balloons, and stents were performed robotically by a physician operator located in an isolated separate room outside the procedure room housing the patient.
Background: Reports of left-sided brain malignancies among interventional cardiologists have heightened concerns regarding physician radiation exposure. This study evaluated the impact of a suspended lead suit and robotic system on physician radiation exposure during percutaneous coronary intervention (PCI).
Methods: Real-time radiation exposure data were prospectively collected from dosimeters worn by operating physicians at the head- and chest-level during consecutive PCI cases.
Objective: In a previous exploratory analysis, intracoronary near-infrared spectroscopy (NIRS) found the majority of culprit lesions in ST-segment-elevation myocardial infarction (STEMI) to contain a maximum lipid core burden index in 4 mm (maxLCBI4mm) of >400. This initial study was limited by a small sample size, enrollment at a single center, and post hoc selection of the maxLCBI4mm ≥400 threshold. This study was designed a priori to substantiate the ability of NIRS to discriminate STEMI culprit from nonculprit segments and to confirm the performance of the maxLCBI4mm ≥400 threshold.
View Article and Find Full Text PDFAims: A recent study demonstrated that intracoronary near-infrared spectroscopy (NIRS) findings in non-target vessels are associated with major adverse cardiovascular and cerebrovascular events (MACCE). It is unknown whether NIRS findings at non-stented sites in target vessels are similarly associated with future MACCE. This study evaluated the association between large lipid-rich plaques (LRP) detected by NIRS at non-stented sites in a target artery and subsequent MACCE.
View Article and Find Full Text PDFBackground: Neoatherosclerosis is an emerging phenomenon in which lipid-rich plaques (LRPs) develop within pre-existing stents. This study was undertaken to describe near-infrared spectroscopy (NIRS) and intravascular ultrasound findings in pre-existing stents and to compare NIRS findings in pre-existing stents, in which an increased lipid signal has been speculated to indicate neoatherosclerosis, and NIRS findings in a control group of freshly implanted stents, in which any lipid signal originates from fibroatheroma under the stent.
Methods And Results: At the site of LRP detected by NIRS in a cohort of pre-existing stents, intravascular ultrasound was used to determine the presence of neointimal tissue.
Objective: This study was performed to assess the lipid burden of culprit lesions in non-ST-segment elevation myocardial infarction (non-STEMI) and unstable angina (UA).
Background: A recent intracoronary near-infrared spectroscopy (NIRS) study showed 85% of STEMI culprit lesions have a maximum lipid core burden index in 4-mm (maxLCBI(4mm)) ≥ 400. Whether culprit lesions in non-STEMI and UA are characterized by a similarly large lipid burden is unknown.