Publications by authors named "Stacey J L Sullivan"

Understanding the loads and stresses on different tissues within the shoulder complex is crucial for preventing joint injury and developing shoulder implants. Finite element (FE) models of the shoulder joint can be helpful in describing these forces and the biomechanics of the joint. Currently, there are no validated FE models of the intact shoulder available in the public domain.

View Article and Find Full Text PDF

Non-contact infrared thermometers (NCITs) are being widely used during the COVID-19 pandemic as a temperature-measurement tool for screening and isolating patients in healthcare settings, travelers at ports of entry, and the general public. To understand the accuracy of NCITs, a clinical study was conducted with 1113 adult subjects using six different commercially available NCIT models. A total of 60 NCITs were tested with 10 units for each model.

View Article and Find Full Text PDF

Unlabelled: Although nitinol is widely used in percutaneous cardiovascular interventions, a causal relationship between nickel released from implanted cardiovascular devices and adverse systemic or local biological responses has not been established. The objective of this study was to investigate the relationship between nitinol surface processing, in-vivo nickel release, and biocompatibility. Nitinol stents manufactured using select surface treatments were implanted into the iliac arteries of minipigs for 6 months.

View Article and Find Full Text PDF

Unlabelled: A major limitation with current assessments of corrosion in metallic medical devices is the lack of correlation between in-vitro and in-vivo corrosion performance. Therefore, the objective of this study was to elucidate the relationship between pitting corrosion measured by breakdown potentials (E) in ASTM F2129 testing and corrosion resistance in-vivo. Four groups of Nitinol stents were manufactured using different processing methods to create unique surface properties.

View Article and Find Full Text PDF

Analysis of explanted medical implants can provide a wealth of knowledge about device safety and performance. However, the quality of information may be compromised if the methods used to clean tissue from the device disturb the retrieved condition. Common solutions used to digest tissue may adversely affect the surface of the device and its severity can be material and processing dependent.

View Article and Find Full Text PDF

The flow and polymerization characteristics of poly(methylmethacrylate) (PMMA) bone cement can be changed by manipulating the temperature of the bone cement components or the environment that they are prepared in. To quantify the effects of the initial component temperature (T(ic)) of acrylic bone cement on the rheological and handling characteristics, ASTM F451-99a compliant methods and clinically relevant testing methods were utilized. A rheometer was designed and fabricated using the dimensions of a clinical, commercially available, cement gun and nozzle.

View Article and Find Full Text PDF