Aim: To investigate the patient-outcomes of newly developed pressure drop coefficient (CDP) in diagnosing epicardial stenosis (ES) in the presence of concomitant microvascular disease (MVD).

Methods: Patients from our clinical trial were divided into two subgroups with: (1) cut-off of coronary flow reserve (CFR) < 2.0; and (2) diabetes.

View Article and Find Full Text PDF

Background: In this study, lesion flow coefficient (LFC: ratio of % area stenosis [%AS] to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow), was assessed for application in a clinical setting.

Methods And Results: Pressure, flow, and anatomical values were obtained from patients in 251 vessels from two different centers. Fractional flow reserve (FFR), Coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR) and hyperemic microvascular index (HMR) were calculated.

View Article and Find Full Text PDF

The hemodynamic and geometric factors leading to propagation of acute Type B dissections are poorly understood. The objective is to elucidate whether geometric and hemodynamic parameters increase the predilection for aortic dissection propagation. A pulse duplicator set-up was used on porcine aorta with a single entry tear.

View Article and Find Full Text PDF

Aim: To combine pressure and flow parameter, pressure drop coefficient (CDP) will result in better clinical outcomes in comparison to the fractional flow reserve (FFR) group.

Methods: To test this hypothesis, a comparison was made between the FFR < 0.75 and CDP > 27.

View Article and Find Full Text PDF

Objectives And Background: Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity.

Methods: Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP.

View Article and Find Full Text PDF

Background: ECG-gated rest-stress cardiac PET can lead to simultaneous quantification of both left ventricular ejection fraction and flow impairment. In this study, our aim was to assess the benefit of rest and stress PET ejection fraction (EF) (EFp) in relation to single-photon emission computed tomography (SPECT) EF (EFs) and echocardiography EF (EFe). To this effect, the EFp was compared with EFs and EFe.

View Article and Find Full Text PDF

To formulate more accurate guidelines for musculoskeletal disorders (MSD) linked to Hand-Arm Vibration Syndrome (HAVS), delineation of the response of bone tissue under different frequencies and duration of vibration needs elucidation. Rat-tails were vibrated at 125 Hz (9 rats) and 250 Hz (9 rats), at 49 m/s(2), for 1D (6 rats), 5D (6 rats) and 20D (6 rats); D=days (4 h/d). Rats in the control group (6 rats for the vibration groups; 2 each for 1D, 5D, and 20D) were left in their cages, without being subjected to any vibration.

View Article and Find Full Text PDF

Invasive diagnosis of coronary artery disease utilizes either anatomical or functional measurements. In this study, we tested a futuristic parameter, lesion flow coefficient (LFC, defined as the ratio of percent coronary area stenosis (%AS) to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow) for application in a clinical setting. In 51 vessels, simultaneous pressure and flow readings were obtained using a 0.

View Article and Find Full Text PDF

Background: Cardiac positron emission tomography (PET) can lead to flow impairment quantification using PET coronary flow reserve (CFRp: ratio of stress flow to rest flow) and is superior to the current standard, single-photon emission computed tomography. In this study, our first aim was to assess the benefit of CFRp in place of invasive CFR (CFRi) by comparing the correlations of each of the indices with combined pressure and flow index CDP, and combined functional (pressure-flow) and anatomical (%area stenosis, %AS) index, LFC. The second aim was to test the correlation between CFRp and CFRi.

View Article and Find Full Text PDF

The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%.

View Article and Find Full Text PDF

Objectives And Background: Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of intermediate stenosis. CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a non-dimensional index derived from fundamental fluid dynamic principles based on a combination of intracoronary pressure and flow, may improve the functional assessment of coronary lesion severity.

View Article and Find Full Text PDF

The decision to perform intervention on a patient with coronary stenosis is often based on functional diagnostic parameters obtained from pressure and flow measurements using sensor-tipped guidewire at maximal vasodilation (hyperemia). Recently, a rapid exchange Monorail Pressure Sensor catheter of 0.022″ diameter (MPS22), with pressure sensor at distal end has been developed for improved assessment of stenosis severity.

View Article and Find Full Text PDF

Currently, the diagnosis of coronary stenosis is primarily based on the well-established functional diagnostic parameter, fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a "gray" zone of 0.75-0.

View Article and Find Full Text PDF

In current practice, diagnostic parameters, such as fractional flow reserve (FFR) and coronary flow reserve (CFR), are used to determine the severity of a coronary artery stenosis. FFR is defined as the ratio of hyperemic pressures distal (p(rh)) and proximal (p(ah)) to a stenosis. CFR is the ratio of flow at hyperemic and basal condition.

View Article and Find Full Text PDF

Objectives And Background: Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV).

View Article and Find Full Text PDF

In this study, coronary diagnostic parameters, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to distal dynamic pressure), and lesion flow coefficient (LFC: ratio of % area stenosis (%AS) to the CDP at throat region), were evaluated to distinguish levels of %AS under varying contractility conditions, in the presence of microvascular disease (MVD). In 10 pigs, %AS and MVD were created using angioplasty balloons and 90-μm microspheres, respectively. Simultaneous measurements of pressure drop, left ventricular pressure (p), and velocity were obtained.

View Article and Find Full Text PDF

Hand-Arm Vibration Syndrome (HAVS) is caused by hand-transmitted vibration in industrial workers. Current ISO guidelines (ISO 5349) might underestimate vascular injury associated with range of vibration frequencies near resonance. A rat-tail model was used to investigate the effects of higher frequencies >100 Hz on early vascular damage.

View Article and Find Full Text PDF

Objectives And Background: Decisions based on invasive functional diagnostic measurements are often made in the setting of fluctuating hemodynamic variables that may alter resting or hyperemic measurements. The purpose of this investigation is to analyze the effect of myocardial contractility (CY) on invasive functional parameters. We hypothesize that the pressure drop coefficient (CDPe; ratio of pressure drop to distal dynamic pressure) and fractional flow reserve (FFR; ratio of average pressures distal and proximal to a stenosis) are not affected by fluctuations in CY and can distinguish between different severities of epicardial stenosis.

View Article and Find Full Text PDF

A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis.

View Article and Find Full Text PDF

Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered.

View Article and Find Full Text PDF