Publications by authors named "Sresty N"

Background: Endometrial cancer is the most common disease of the female reproductive system. Vaginal cuff brachytherapy (VCB) has intrinsic advantages compared to external beam therapy when treated with radiation. A single-channel cylinder is a standard applicator in VCB.

View Article and Find Full Text PDF

Purpose: To report the feasibility of performing hybrid intra-cavitary and interstitial (IC/IS) brachytherapy in patients with carcinoma cervix under trans-rectal ultrasound (TRUS) guidance.

Material And Methods: All patients who received an external beam radiotherapy (EBRT) dose of 50 Gy in 25 fractions with weekly chemotherapy, followed by a brachytherapy boost (21 Gy in 3 fractions) were prospectively included for analysis. IC/IS brachytherapy was performed using Fletcher style tandem and ovoid applicator with interstitial component under TRUS guidance.

View Article and Find Full Text PDF

Purpose: The aim of the study was to compare the dose to vaginal points between two intracavitary applicators used for HDR brachytherapy in Carcinoma Cervix METHODS AND MATERIALS: Patients reporting to our center for Carcinoma cervix intracavitary brachytherapy were randomly allocated to treatment with either Manchester or Fletcher Suit Delclos (FSD) applicator. All patients received an EBRT dose of 50 Gy in 25 fractions along with weekly Cisplatin (40 mg/m). Brachytherapy was administered using CT based planning.

View Article and Find Full Text PDF

The primary purpose of the study is to evaluate the implementation of Helical TomoTherapy (HT) for eligible stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy (SRS/SBRT/SABR) cases using TomoEDGE option. The study focuses on reduction of treatment time without compromise in plan quality using TomoEDGE. It is a mode in HT that uses a dynamic opening of the jaws during treatment delivery to reduce the dose penumbra which otherwise is not possible with fixed jaws option.

View Article and Find Full Text PDF

Purpose: Total body irradiation (TBI) can be safely delivered on TomoTherapy (Accuray, Sunnyvale, CA, USA) in both pediatric and adult patients with proper imaging and planning despite the length constraint of 135 cm. To overcome this limitation, two CT (Computed Tomography) scans (CT1& CT2) are taken in patients above 135 cm in height. Adequate junction dose coverage is important in TBI.

View Article and Find Full Text PDF

Introduction: Breast cancer (BC) is the most common cancer in Indian females. The irradiation of internal mammary lymph nodal area (IMLN) is recommended by latest guidelines and literature, even in patients with N1 nodal disease, but it is not routinely done in many institutes due to the risk of late lung and heart toxicities. The incidence of isolated IMLN recurrence <1%.

View Article and Find Full Text PDF

Aim: This study represents an enumeration and comparison of gross target volumes (GTV) as delineated independently on contrast-enhanced computed tomography (CT) and T1 and T2 weighted magnetic resonance imaging (MRI) in vestibular schwannomas (VS).

Background: Multiple imaging in radiotherapy improves target localization.

Methods And Materials: 42 patients of VS were considered for this prospective study with one patient showing bilateral tumor.

View Article and Find Full Text PDF

Aim Of The Study: Statistical analysis of pre-treatment dose verification of intensity-modulated radiotherapy (IMRT) fields to assess the quality of the IMRT practice at different radiotherapy centers.

Materials And Methods: The dose verification data acquired by the institutional physicist of 10 different hospitals for various types of patients were collected and analyzed for mean, median, standard deviation (SD), range, minimum and maximum % deviation. The percentage of cases having positive and negative dose differences as well dose differences within ± 3% were also determined.

View Article and Find Full Text PDF

In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source.

View Article and Find Full Text PDF

Purpose: Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment plans.

View Article and Find Full Text PDF

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal Radiotherapy (3D-CRT), and Intensity Modulated Radiotherapy (IMRT) for different sites, and to study the suitability of algorithms with respect to site and technique. For each of the Conventional, 3D-CRT, and IMRT techniques, four different sites, namely, Lung, Esophagus, Prostate, and Hypopharynx were analyzed. Treatment plans were created using 6MV Photon beam quality using the CMS XiO (Computerized Medical System, St.

View Article and Find Full Text PDF

Purpose: Intensity-modulated radiotherapy (IMRT) technique in external beam radiotherapy and interstitial implant brachytherapy (ISBT) play important role in the treatment of head and neck cancers. Both are proved to be highly conformal techniques of radiotherapy. In this study, we investigated whether ISBT can give treatment planning results similar to those of IMRT.

View Article and Find Full Text PDF

Measurements designed to find the collimator backscatter into the beam monitor chamber from Micro Multileaf collimator of 6 MV photon beams of the Siemens Primus linear accelerator were made with the help of dose rate feedback control. The photons and electrons backscattered from the upper and lower secondary collimator jaws give rise to a significant increase in the ion charge measured by monitor chamber. This increase varies between the different accelerators.

View Article and Find Full Text PDF