Purpose: Our purpose was to determine and model the dose-response relations of different parts of the pelvis regarding the endpoint of hematocrit level drop after pelvic radiation therapy (RT).
Methods And Materials: Two hundred and twenty-one patients treated with RT for prostate adenocarcinoma between 2014 and 2016 were included. All patients had complete blood counts collected at baseline and 3 months post-RT.
Background: Radiotherapy dose predictions have been trained with data from previously treated patients of similar sites and prescriptions. However, clinical datasets are often inconsistent and do not contain the same number of organ at risk (OAR) structures. The effects of missing contour data in deep learning-based dose prediction models have not been studied.
View Article and Find Full Text PDFThe purpose is to reduce normal tissue radiation toxicity for electron therapy through the creation of a surface-conforming electron multileaf collimator (SCEM). The SCEM combines the benefits of skin collimation, electron conformal radiotherapy, and modulated electron radiotherapy. An early concept for the SCEM was constructed.
View Article and Find Full Text PDFIntroduction: Numerous studies have proven the Monte Carlo method to be an accurate means of dose calculation. Although there are several commercial Monte Carlo treatment planning systems (TPSs), some clinics may not have access to these resources. We present a method for routine, independent patient dose calculations from treatment plans generated in a commercial TPS with our own Monte Carlo model using free, open-source software.
View Article and Find Full Text PDF. The aim of this work is an AI based approach to reduce the volume effect of ionization chambers used to measure high energy photon beams in radiotherapy. In particular for profile measurements, the air-filled volume leads to an inaccurate measurement of the penumbra.
View Article and Find Full Text PDFPurpose: To determine the severity of the effects on VMAT dose calculations caused by varying statistical uncertainties (SU) per control point in a Monte Carlo based treatment planning system (TPS) and to assess the impact of the uncertainty during dose volume histogram (DVH) evaluation.
Methods: For this study, 13 archived patient plans were selected for recalculation. Treatment sites included prostate, lung, and head and neck.
Aim: The aim of this study was to measure and compare the output factor (OF) of a CyberKnife Robotic Radiosurgery System with eight different small field detectors and validate with Technical Report Series (TRS) report 483.
Background: Accurate dosimetry of CyberKnife system is limited due to the challenges in small field dosimetry. OF is a vital dosimetric parameter used in the photon beam modeling and any error would affect the dose calculation accuracy.
Purpose: To develop a simplified aluminum compensator system for total body irradiation (TBI) that is easy to assemble and modify in a short period of time for customized patient treatments.
Methods: The compensator is composed of a combination of 0.3 cm thick aluminum bars, two aluminum T-tracks, spacers, and metal bolts.
Purpose: For mobile lung tumors, four-dimensional computer tomography (4D CT) is often used for simulation and treatment planning. Localization accuracy remains a challenge in lung stereotactic body radiation therapy (SBRT) treatments. An attractive image guidance method to increase localization accuracy is 4D cone-beam CT (CBCT) as it allows for visualization of tumor motion with reduced motion artifacts.
View Article and Find Full Text PDFPurpose: Studies have evaluated the viability of using open-face masks as an immobilization technique to treat intracranial and head and neck cancers. This method offers less stress to the patient with comparable accuracy to closed-face masks. Open-face masks permit implementation of surface guided radiation therapy (SGRT) to assist in positioning and motion management.
View Article and Find Full Text PDFDose enhancement due to gold nanoparticles (GNPs) has been quantified experimentally and through Monte Carlo simulations for external beam radiation therapy energies of 6 and 18 MV. The highest enhancement was observed for the 18 MV beam at the highest GNP concentration tested, amounting to a DEF of 1.02.
View Article and Find Full Text PDFBackground: The increased use of deformable registration algorithms in clinical practice has also increased the need for their validation.
Aims And Objectives: The purpose of the study was to investigate the quality, accuracy, and plausibility of three commercial image registration algorithms for 4-dimensional computed tomography (4DCT) datasets using various similarity measures.
Materials And Methods: 4DCT datasets were acquired for 10 lung cancer patients.
Purpose: Monaco treatment planning system (TPS) version 5.1 uses a Monte-Carlo (MC)-based dose calculation engine. The aim of this study is to verify and compare the Monaco-based dose calculations with both Pinnacle collapsed cone convolution superposition (CCCS) and Eclipse anisotropic analytical algorithm (AAA) calculations.
View Article and Find Full Text PDFPurpose: To compare the accuracy of two separate models when calculating dose distributions in patients undergoing stereotactic radiosurgery (SRS) treatment for brain cancer.
Methods: For this comparison, two dose calculation algorithms were evaluated on two different treatment planning systems (TPS): Elekta's Monaco Version 5.11.
The era of real-time radiotherapy is upon us. Robotic and gimbaled linac tracking are clinically established technologies with the clinical realization of couch tracking in development. Multileaf collimators (MLCs) are a standard equipment for most cancer radiotherapy systems, and therefore MLC tracking is a potentially widely available technology.
View Article and Find Full Text PDFPurpose: To create an open-source visualization program that allows one to find potential cone collisions while planning intracranial stereotactic radiosurgery cases.
Methods: Measurements of physical components in the treatment room (gantry, cone, table, localization stereotactic radiation surgery frame, etc.) were incorporated into a script in MATLAB (MathWorks, Natick, MA) that produces three-dimensional visualizations of the components.
Purpose: Single-isocenter multiple brain metastasis stereotactic radiosurgery is an efficient treatment modality increasing in clinical practice. The need to provide accurate, patient-specific quality assurance (QA) for these plans is met by several options. This study reviews some of these options and explores the use of the Octavius 4D as a solution for patient-specific plan quality assurance.
View Article and Find Full Text PDFGold nanoparticles (GNPs) have been studied extensively as promising radiation dose enhancing agents. In the current study, the dose enhancement effect of GNPs for Ir-192 HDR brachytherapy is studied using Monte Carlo N-Particle code, version 6.2 (MCNP6.
View Article and Find Full Text PDFPurpose: Dose-volume histogram (DVH) measurements have been integrated into commercially available quality assurance systems to provide a metric for evaluating accuracy of delivery in addition to gamma analysis. We hypothesize that tumor control probability and normal tissue complication probability calculations can provide additional insight beyond conventional dose delivery verification methods.
Methods: A commercial quality assurance system was used to generate DVHs of treatment plan using the planning CT images and patient-specific QA measurements on a phantom.
Introduction: This research quantifies and compares the effect of hip prostheses on dose distributions calculated using collapsed cone convolution superposition and Monte Carlo (with and without correcting for the density of the implant and surrounding tissues). The use of full volumetric modulated arc therapy arcs versus volumetric modulated arc therapy arcs avoiding the hip implants (skip arcs) was also studied.
Materials And Methods: Six prostate patients with hip prostheses were included in this study.
Background: The prevention of radiation-induced liver disease (RILD) is very significant in ensuring a safe radiation treatment and high quality of life.
Aims And Objectives: The purpose of this study is to investigate the correlation of physical and biological effective dose (BED) metrics with liver toxicity from hypo-fractionated liver radiotherapy.
Materials And Methods: 41 hypo-fractionated patients in 2 groups were evaluated for classic radiation-induced liver disease (RILD) and chronic RILD, respectively.
Introduction: Clinical evaluation of a two-dimensional (2D) liquid-filled ion chamber detector array used in the verification of highly modulated small beams of stereotactic body radiation therapy (SBRT) has been conducted.
Materials And Methods: Measurements with the Octavius 1000 SRS (PTW, Freiburg, Germany) detector with 977 liquid-filled ion chambers were compared against EDR2 film and PTW Octavius Seven29. The performance of detector array has been evaluated on ten SBRT patient plans.