Publications by authors named "Sorce A"

: Considering the physiological analogies between the eye and the kidney, this study aimed to investigate the potential relationship between retinal vascular density, assessed using Optical Coherence Tomography Angiography (OCT-A), and the renal resistive index (RRI) in patients with arterial hypertension. : A total of 82 hypertensive patients (mean age 48 ± 13) were enrolled in the study. Participants underwent routine biochemical evaluations, office-based blood pressure measurement, 24 h ambulatory blood pressure monitoring, OCT-A imaging, and renal Doppler ultrasound examinations.

View Article and Find Full Text PDF

Background: The neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio, and derived-neutrophil-to-lymphocyte ratio (d-NLR), which can be obtained from complete blood count, have gained attention due to their widespread availability and low cost of testing; they have recently been proposed as prognostic markers in various chronic diseases. The primary objective of our study was to investigate the potential prognostic role of inflammatory markers derived from blood cell counts regarding all-cause mortality in patients with kidney failure undergoing hemodialysis, and the use of such markers in risk stratification based on the type of vascular access used.

Methods: This retrospective study included 236 patients from the Nephrology Unit  of Trento.

View Article and Find Full Text PDF

Introduction: The following presentation explores the diagnostic potential of Contrast-Enhanced Mammography (CEM) in evaluating and managing Paget's Disease (PD) of the breast, particularly as an alternative or complementary tool to Magnetic Resonance Imaging (MRI) in cases where MRI is contraindicated or inconclusive.

Clinical Cases: Two clinical cases of PD diagnosed at our Breast Imaging Division between January and May 2024 were analyzed using CEM. These cases involved imaging techniques, including Digital Mammography (DM), Breast Ultrasound (US), MRI and CEM, alongside histopathological confirmation through nipple-areolar complex (NAC) punch biopsies.

View Article and Find Full Text PDF

Contrast-enhanced mammography (CEM) has recently gained recognition as an effective alternative to breast magnetic resonance imaging (MRI) for assessing breast lesions, offering both morphological and functional imaging capabilities. However, the phenomenon of background parenchymal enhancement (BPE) remains a critical consideration, as it can affect the interpretation of images by obscuring or mimicking lesions. While the impact of BPE has been well-documented in MRI, limited data are available regarding the factors influencing BPE in CEM and its relationship with breast cancer (BC) characteristics.

View Article and Find Full Text PDF

The complications of hypertension depend not only on the mean blood pressure (BP) but also on its variability (BPV). Recent studies suggest that the choroid may serve as an indicator of systemic vascular damage. These studies have been made possible by the increased availability of optical coherence tomography (OCT).

View Article and Find Full Text PDF
Article Synopsis
  • - The study assesses how well MRI can diagnose breast implant ruptures and the effect of radiologist experience on accuracy.
  • - It involved 118 patients who had implant surgeries, finding that expert radiologists detected ruptures with much greater accuracy compared to less experienced ones.
  • - The results highlight the need for specialized training in radiology to enhance diagnostic precision, prompting a recommendation for updated radiological guidelines.
View Article and Find Full Text PDF

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium-tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al.

View Article and Find Full Text PDF

Radiological interpretations, while essential, are not infallible and are best understood as expert opinions formed through the evaluation of available evidence. Acknowledging the inherent possibility of error is crucial, as it frames the discussion on improving diagnostic accuracy and patient care. A comprehensive review of error classifications highlights the complexity of diagnostic errors, drawing on recent frameworks to categorize them into perceptual and cognitive errors, among others.

View Article and Find Full Text PDF
Article Synopsis
  • The authors conducted a narrative review to highlight the latest research on ultrasound's application in major rheumatic disorders like rheumatoid arthritis, psoriatic arthritis, and crystal-induced arthropathies.
  • They performed a comprehensive search on PubMed to gather articles that discuss updates on ultrasound use in these conditions.
  • The review offers new definitions, criteria, and diagnostic scores, emphasizing the significance of ultrasound in enhancing patient care in rheumatic diseases.
View Article and Find Full Text PDF

In the landscape of cancer treatment, particularly in the realm of breast cancer management, effective communication emerges as a pivotal factor influencing patient outcomes. This article delves into the nuanced intricacies of communication skills, specifically spotlighting the strategies embraced by breast radiologists. By examining the ramifications of communication on patient experience, interdisciplinary collaboration, and legal ramifications, this study underscores the paramount importance of empathetic and comprehensive communication approaches.

View Article and Find Full Text PDF

Breast cancer remains the most prevalent cancer among women worldwide, necessitating advancements in diagnostic methods. The integration of artificial intelligence (AI) into mammography has shown promise in enhancing diagnostic accuracy. However, understanding patient perspectives, particularly considering the psychological impact of breast cancer diagnoses, is crucial.

View Article and Find Full Text PDF

The performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium-tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature.

View Article and Find Full Text PDF

Purpose: The aim of this study was to describe the safety and efficacy profiles of TACE using DC Beads LUMI.

Materials And Methods: We retrospectively analyzed 90 patients with HCC who underwent TACE with DC Bead LUMI™ between November 2018 and November 2020 at Fondazione IRCCS Cà Granda Policlinico Hospital in Milan, Italy. Patient- and tumour-related factors were registered, including the number of treated lesions, dose of DC Beads LUMI™, dose of Epirubicin, DC Beads LUMI™ target tumour coverage (LC) according to the percentage of target nodule involvement (LC1-0%-25%, LC2-25%-50%, LC3-50%-75%, LC4 75%-100%).

View Article and Find Full Text PDF

All severe cases of SARS-CoV-2 infections are characterized by a high risk of disease progression towards ARDS, leading to a bad outcome. Respiratory symptoms in COVID-19 patients often do not correspond to disease's worsening. In our sample, median age was 74 years (72-75) and 54% were men.

View Article and Find Full Text PDF

The advent of artificial intelligence (AI) represents a real game changer in today's landscape of breast cancer imaging. Several innovative AI-based tools have been developed and validated in recent years that promise to accelerate the goal of real patient-tailored management. Numerous studies confirm that proper integration of AI into existing clinical workflows could bring significant benefits to women, radiologists, and healthcare systems.

View Article and Find Full Text PDF

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium-tritium plasma [B. M.

View Article and Find Full Text PDF

A system of x-ray imaging spectrometer (XRIS) has been implemented at the OMEGA Laser Facility and is capable of spatially and spectrally resolving x-ray self-emission from 5 to 40 keV. The system consists of three independent imagers with nearly orthogonal lines of sight for 3D reconstructions of the x-ray emission region. The distinct advantage of the XRIS system is its large dynamic range, which is enabled by the use of tantalum apertures with radii ranging from 50 μm to 1 mm, magnifications of 4 to 35×, and image plates with any filtration level.

View Article and Find Full Text PDF

Electron-temperature (T) measurements in implosions provide valuable diagnostic information, as T is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T(t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (∼15 ps) scintillator-channels with distinct x-ray filtering.

View Article and Find Full Text PDF

The neutrophil-to-lymphocyte ratio (NLR) is an inflammatory marker predicting the prognosis of several diseases. We aimed to assess its role as a predictor of mortality or admission to the intensive care unit in COVID-19 patients. We retrospectively evaluated a cohort of 411 patients with COVID-19 infection.

View Article and Find Full Text PDF

Electron-temperature (T) measurements in implosions provide valuable diagnostic information, as T is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T(t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (∼15 ps) scintillator channels with distinct x-ray filtering.

View Article and Find Full Text PDF

It has long been known that blood pressure (BP) is characterized by marked short-term fluctuations occurring within a 24-h period and also by long-term oscillations occurring over more prolonged periods of time. An increased short-term blood pressure variability (BPV) appears to importantly contribute to target organ damage and to the enhanced cardiovascular risk of hypertensive patients, over and above the effect of an increase in mean BP levels. Reducing 24-h mean BP is the main aim of antihypertensive therapy, but initial data are available that additional cardiovascular protection can be achieved by reducing BPV.

View Article and Find Full Text PDF

Controversy exists about the association of choroidal thickness (CTh) with blood pressure (BP) values. There is some evidence suggesting that central hemodynamics changes are associated with microvascular disease. Our study was aimed to assess the relationships between CTh and clinic and 24-h BP and between CTh and estimated 24-h aortic pulse pressure (aPP), 24-h aortic systolic BP (aSBP), and 24-h aortic augmentation index (aAIx) in a group of hypertensive patients.

View Article and Find Full Text PDF