Low-dose methotrexate has been proposed as therapy for patients with severely disabling psoriasis and psoriatic arthritis. However, it can be associated with severe toxicity, such as pancytopenia, characterized by anemia (hemoglobin level <13 g/dL in men), thrombocytopenia (platelet count <150 × 109/L), and neutropenia or agranulocytosis (neutrophil count <1.5 × 109/L and 0.
View Article and Find Full Text PDFAntibiotics (Basel)
August 2024
To rapidly achieve ceftazidime target concentrations, a 2 g loading dose (LD) is recommended before continuous infusion, but its adequacy in critically ill patients, given their unique pharmacokinetics, needs investigation. This study included patients from six ICUs in Saint-Etienne and Paris, France, who received continuous ceftazidime infusion with plasma concentration measurements. Using MONOLIX and R, a pharmacokinetic (PK) model was developed, and the literature on ICU patient PK models was reviewed.
View Article and Find Full Text PDFBackground: The case study discusses a complex scenario involving the use of amoxicillin in a critically ill patient undergoing intermittent renal replacement therapy.Severe infections are complicated by septic shock and organ failure, requiring urgent and effective antibiotic treatment.
Methods: The patient's comorbidities, including obesity and acute kidney injury, required careful consideration of the amoxicillin dosing strategies.
Cefotaxime administration is recommended in doses of 3-12 g/day in adults with a Glomerular Filtration Rate (GFR) > 5 mL/min. This study aimed to assess the impact of renal function and obesity on cefotaxime concentrations in intensive care unit (ICU) patients. A retrospective cohort study was conducted on consecutive ICU patients receiving continuous cefotaxime infusion between 2020 and 2022 [IRBN992021/CHUSTE].
View Article and Find Full Text PDFThis work aims to investigate bronchodilator delivery with the use of different vaping drug delivery systems (VDDS) by determining the dose equivalence delivered in relation to different references: a clinical jet nebulizer, a pMDI (pressurized metered dose inhaler) and a DPI (dry powder inhaler). Three different bronchodilators were used (terbutaline, salbutamol hemisulfate, ipratropium bromide). The e-liquids contained the active pharmaceutical ingredient (API) in powder form.
View Article and Find Full Text PDFBackground: Ceftazidime is commonly used as a key antibiotic against Pseudomonas aeruginosa in critically ill patients. ICU patients have severely altered and variable antibiotic pharmacokinetics, resulting in lower antimicrobial concentrations and potentially poor outcome. Several factors, including obesity and renal function, may influence pharmacokinetics.
View Article and Find Full Text PDFPurpose: To describe the long-term physical, functional and mental status of COVID-19 intensive care unit (ICU) patients and their family members 1 year after ICU discharge.
Methods: We performed a prospective observational cohort study among patients admitted to the ICU for COVID-19-associated respiratory failure and their family members. Patients attended a one-year follow-up consultation with family members.
Successful aerosol therapy in mechanically ventilated patients depends on multiple factors. Among these, position of nebulizer in ventilator circuit and humidification of inhaled gases can strongly influence the amount of drug deposited in airways. Indeed, the main objective was to preclinically evaluate impact of gas humidification and nebulizer position during invasive mechanical ventilation on whole lung and regional aerosol deposition and losses.
View Article and Find Full Text PDFPurpose: Several technical features influencing bronchodilator delivery were evaluated using different vaping drug delivery systems (VDDS).
Methods: Terbutaline in powder form, combined with 1, 3- propanediol used as e-liquid was tested at different concentrations (1 and 2.5 mg/mL), power levels (15 W and 30 W), and set applied resistances (0.
Expert Opin Drug Metab Toxicol
April 2022
Introduction: Ceftazidime is used for the treatment of many bacterial infections, including severe infections. Like other beta-lactams, inter-individual variability in ceftazidime pharmacokinetics has been described. Due to its related pathophysiological modifications, obesity might influence ceftazidime pharmacokinetics.
View Article and Find Full Text PDFPurpose: The performance of new-generation high-power electronic nicotine delivery system (ENDS) for the administration of inhaled terbutaline was assessed.
Methods: The formulation of e-liquid was carried out using terbutaline in combination with 1, 3- propanediol. Several terbutaline concentrations (from 0.
In this article, we present a case of apixaban elimination prolonged by 450% in a patient with coronavirus disease 2019 because of multiple conditions, including drug-drug interaction, severe inflammation, and acute kidney injury. Therapeutic drug monitoring was used to explain unusual routine coagulation assays. This grand round highlights the importance of dialog between the clinician and a therapeutic drug monitoring consultant for optimal patient care.
View Article and Find Full Text PDFIdiopathic pulmonary fibrosis is a progressive disease with unsatisfactory systemic treatments. Aerosol drug delivery to the lungs is expected to be an interesting route of administration. However, due to the alterations of lung compliance caused by fibrosis, local delivery remains challenging.
View Article and Find Full Text PDFIn intensive care units, nebulization is a usual route for drug administration to patients under mechanical ventilation (MV). The effectiveness of inhalation devices as well as depositions sites of aerosols for ventilated patients remain poorly documented. In vivo human inhalation studies are scarce due to ethical restrictions because imaging techniques require radioaerosols to assess regional aerosol deposition.
View Article and Find Full Text PDFBackground: Hemodynamic response to prone position (PP) has never been studied in a large series of patients with acute respiratory distress syndrome (ARDS). The primary aim of this study was to estimate the rate of PP sessions associated with cardiac index improvement. Secondary objective was to describe hemodynamic response to PP and during the shift from PP to supine position.
View Article and Find Full Text PDFBackground: Predicting fluid responsiveness may help to avoid unnecessary fluid administration during acute respiratory distress syndrome (ARDS). The aim of this study was to evaluate the diagnostic performance of the following methods to predict fluid responsiveness in ARDS patients under protective ventilation in the prone position: cardiac index variation during a Trendelenburg maneuver, cardiac index variation during an end-expiratory occlusion test, and both pulse pressure variation and change in pulse pressure variation from baseline during a tidal volume challenge by increasing tidal volume (VT) to 8 ml.kg.
View Article and Find Full Text PDFBackground: Limiting tidal volume (V) in patients with ARDS may not be achieved once patient-triggered breaths occur. Furthermore, ICU ventilators offer numerous patient-triggered modes that work differently across brands. We systematically investigated, using a bench model, the effect of patient-triggered modes on the size and variability of V at different breathing frequencies (f), patient effort, and ARDS severity.
View Article and Find Full Text PDFTo offer an enhanced and well-controlled nicotine delivery from the refill liquid to the aerosol is a key point to adequately satisfy nicotine cravings using electronic nicotine delivery systems (ENDS). A recent high-power ENDS, exhibiting higher aerosol nicotine delivery than older technologies, was used. The particle size distribution was measured using a cascade impactor.
View Article and Find Full Text PDFPurpose: A need remains for alternative devices for aerosol drug delivery that are low cost, convenient and easy to use for the patient, but also capable of producing small-sized aerosol particles. This study investigated the potential of recent high power electronic nicotine delivery systems (ENDS) as aerosol generation devices for inhaled bronchodilators.
Methods: The particle size distribution was measured using a cascade impactor.