IEEE Trans Biomed Circuits Syst
February 2024
This review article provides a comprehensive overview of impedance-readout integrated circuits (ICs) for electrical impedance spectroscopy (EIS) applications. The readout IC, a crucial component of on-chip EIS systems, significantly affects key performance metrics of the entire system, such as frequency range, power consumption, accuracy, detection range, and throughput. With the growing demand for portable, wearable, and implantable EIS systems in the Internet-of-Things (IoT) era, achieving high energy efficiency while maintaining a wide frequency range, high accuracy, wide dynamic range, and high throughput has become a focus of research.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
October 2023
This article presents a wireless and wearable body-pressure-monitoring system for the on-site, real-time prevention of pressure injuries for immobilized patients. For the prevention of pressure-induced skin injuries, a wearable pressure sensor system is designed to monitor the pressure at multiple sites on the skin and to alert the danger of prolonged application of pressure on the skin with a pressure-time integral (PTI) algorithm. The wearable sensor unit is developed using a pressure sensor based on a liquid metal microchannel and integrated with a flexible printed circuit board that includes a thermistor-type temperature sensor.
View Article and Find Full Text PDFThis paper presents a wireless kitchen fire prevention system that can detect and notify the fire risk caused by gas stoves. The proposed system consists of two modules. The sensor module detects the concentration of carbon dioxide (CO2) near the gas stove and transmits the monitoring results wirelessly.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
June 2022
This paper reviews architectures and circuit implementations of on-chip sinusoidal signal generators (SSGs) for electrical impedance spectroscopy (EIS) applications. In recent years, there have been increasing interests in on-chip EIS systems, which measure a target material's impedance spectrum over a frequency range. The on-chip implementation allows EIS systems to have low power and small form factor, enabling various biomedical applications.
View Article and Find Full Text PDFThis paper presents an error-tolerant and power-efficient impedance measurement scheme for bioimpedance acquisition. The proposed architecture measures the magnitude and the real part of the target complex impedance, unlike other impedance measurement architectures measuring either the real/imaginary components or the magnitude and phase. The phase information of the target impedance is obtained by using the ratio between the magnitude and the real components.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
December 2021
In this paper, we present a new impedance measurement integrated circuit (IC) for achieving a wideband coverage up to 10 MHz and low power consumption. A frequency-shift technique is applied to down-shift the input frequency, which ranges from 100 kHz to 10 MHz, into an intermediate frequency of 10 kHz, while the frequency-shifting is bypassed when the input frequency falls in the range from 100 Hz to 100 kHz. It results in 100 times relaxation of the requirement on the instrumentation amplifier (IA) bandwidth and the comparator delay, greatly reducing overall power consumption.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
This paper presents a highly scalable readout IC for high-density microelectrode arrays (MEAs). Although the recent development of large-scale high-density MEAs provides opportunities to achieve sub-cellular neural recording over a wide network area, it is challenging to implement the readout IC that can operate with such MEAs. The requirement of high-speed recording in large-scale arrays induces wideband-noise folding, which makes it challenging to achieve a good noise performance for high-fidelity neural recording.
View Article and Find Full Text PDFRadiation sensor interfaces for battery-powered mobile dosimeters must consume low power to monitor the amount of radiation exposure over a long period. This paper proposes a power-efficient radiation sensor interface using a peak-triggered sampling scheme. Since the peak of the analog-to-digital converter's (ADC's) input represents radiation energy, our ADC only operates around the peak value thanks to the proposed sampling scheme.
View Article and Find Full Text PDFThis paper presents a reconfigurable time-to-digital converter (TDC) used to quantize the phase of the impedance in electrical impedance spectroscopy (EIS). The TDC in the EIS system must handle a wide input-time range for analysis in the low-frequency range and have a high resolution for analysis in the high-frequency range. The proposed TDC adopts a coarse counter to support a wide input-time range and cascaded time interpolators to improve the time resolution in the high-frequency analysis without increasing the counting clock speed.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
January 2014
A suspected sibutramine analogue was detected in a slimming functional food by an ultra performance liquid chromatography-electrospray ionisation-time of flight mass spectrometry (UPLC-ESI-TOF/MS) method. The ultraviolet (UV) spectrum of this suspected compound showed close similarity to that of sibutramine. The sample was extracted with 70% MeOH and isolated by semi-preparative column chromatography.
View Article and Find Full Text PDF