Publications by authors named "Song Tianming"

Despite the numerous available treatments for cancer, many patients succumb to side effects and reoccurrence. Zinc oxide (ZnO) quantum dots (QDs) are inexpensive inorganic nanomaterials with potential applications in photodynamic therapy. To verify the photoluminescence of ZnO QDs and determine their inhibitory effect on tumors, we synthesized and characterized ZnO QDs modified with polyvinylpyrrolidone.

View Article and Find Full Text PDF

Cerenkov luminescence imaging is an emerging optical technique for imaging the distribution of radiopharmaceuticals in vivo. However, because of the light scattering effect, it cannot obtain optical information from deep internal organs. To overcome this challenge, we established a novel endoscopic Cerenkov luminescence imaging system that used a clinically approved laparoscope and an electron-multiplying charge-coupled device camera.

View Article and Find Full Text PDF

Cerenkov luminescence tomography (CLT) is a promising tool that enables three-dimensional noninvasive in vivo detection of radiopharmaceuticals. Conventionally, multispectral information and diffusion theory were introduced to achieve whole-body tomographic reconstruction. However, the diffusion theory inevitably causes systematic error in blue bands of the electromagnetic spectrum due to high-tissue absorption, and CL has a blue-weighted broad spectrum.

View Article and Find Full Text PDF

Cerenkov luminescence imaging utilizes visible photons emitted from radiopharmaceuticals to achieve in vivo optical molecular-derived signals. Since Cerenkov radiation is weak, non-optimum for tissue penetration and continuous regardless of biological interactions, it is challenging to detect this signal with a diagnostic dose. Therefore, it is challenging to achieve useful activated optical imaging for the acquisition of direct molecular information.

View Article and Find Full Text PDF

Multimodality imaging of positron emission tomography/computed tomography (PET/CT) provides both metabolic information and the anatomic structure, which is significantly superior to either PET or CT alone and has greatly improved its clinical applications. Because of the higher soft-tissue contrast of magnetic resonance imaging (MRI) and no extra ionizing radiation, PET/MRI imaging is the hottest topic currently. PET/MRI is swiftly making its way into clinical practice.

View Article and Find Full Text PDF

Measuring the x-ray flux exiting the target's laser entrance hole (LEH) is the most common diagnostic that quantifies the x-ray intensity inside the laser-driven hohlraum. However, this signal accounts for only a small portion of the incident laser power and thus is likely to be affected by unwanted x-ray background from non-target area, leading to an overestimation of the hohlraum drive. Unwanted emission might be produced when the laser light is clipped by the LEH (LEH clipping) because of a lack of clearance for laser spot, or with a laser spot comprising of discrete structure, or even with a poor pointing accuracy.

View Article and Find Full Text PDF

The first observation of the K-shell photoabsorption edge of strongly coupled matter with an ion-ion coupling parameter of about 65 generated by intense x-ray radiation-driven shocks is reported. The soft x-ray radiation generated by laser interaction with a "dog bone" high-Z hohlraum is used to ablate two thick CH layers, which cover a KCl sample, to create symmetrical inward shocks. While the two shocks impact at the central KCl sample, a highly compressed KCl is obtained with a density of 3-5 times solid density and a temperature of about 2-4 eV.

View Article and Find Full Text PDF

A method for the recovery of soft x-ray spectra in indirect-drive inertial confinement fusion experiments is presented. Virtual detection channels with bandpass responses are obtained using linear combinations of the channel response functions of a filtered x-ray diode array and a weighted correction is introduced to improve the recovery. These virtual channels can be used to calculate radiation fluxes in some specific photon energy bands and hence to recover the spectrum of the whole photon energy range from 80 eV to 4.

View Article and Find Full Text PDF

The proposal of simultaneously determining the hohlraum peak radiation temperature T(R) and M-band fraction f(M) by shock velocity measurement technique [Y. S. Li et al.

View Article and Find Full Text PDF

This note describes multi-updates of the novel flat-response x-ray detector in fabrication technology, experimental application, and data uncertainty evaluation. Unlike the previous design, the compound filter is combined into one piece through an improved fabrication process that greatly enhanced its self-supporting capability. A method of pinhole-array imaging is introduced into the experimental application process to stop any debris from the hohlraum and to uniformly reduce the radiation flux.

View Article and Find Full Text PDF

A novel flat-response x-ray detector has been developed for the measurement of radiation flux from a hohlraum. In order to obtain a flat response in the photon energy range of 0.1-4 keV, it is found that both the cathode and the filter of the detector can be made of gold.

View Article and Find Full Text PDF