Introduction: In the present paper, we show a rare case of the large abdominal wall defect and enterocutaneous fistulas after the tension free repair using prostheses for incisional hernia.
Presentation Of Case: The patient, a 70-year-old man, had a history of a hemicolectomy for a perforating colon cancer, complicated by a large incisional hernia that was closed primarily but recurred. Three years later, the hernia was repaired at the time of a second colectomy using a Composix Kugel Patch.