Introduction: Various benefits of needleless suture loop techniques in anterior cruciate ligament reconstruction graft preparation have been discussed, yet their impact on graft diameter remains unexplored. We hypothesized that the suture loop technique would reduce the graft diameter compared to the conventional locking suture technique.
Methods: Fifty-seven patients whose grafts were made with the Krackow stitch (group K) and 54 patients with the suture loop (group SL) were analyzed retrospectively.
The anterior cruciate ligament (ACL) TightRope RT (TR) was recently introduced as a novel cortical suspension device for ACL reconstruction. It has an adjustable graft loop that gives the surgeon some advantages during ACL reconstruction. We report three patients who required removal of the TR after an outside-in anatomical ACL reconstruction because of lateral knee pain.
View Article and Find Full Text PDF