Publications by authors named "So Hung Huynh"

There is hitherto a lack of a simple way to disrupt the coating of particles from liquid marbles in order to introduce additional reagents. Here, a 40 μL liquid marble, created on a superhydrophobic substrate with a 2 mm hole, forms an overhead and overhanging liquid component from which a single gas bubble of up to 28 μL volume could be introduced via the latter. This caused a localized clearing of the particle shell at the apical region of the overhead component because the particles could not be energetically sustained at the thin film region of the bubble.

View Article and Find Full Text PDF

Facile creation of multiple drops at appropriate volumes on surfaces without the use of sophisticated instrumentation facilitates downstream evaporative preconcentration of liquid samples for analytical purposes. In this work, a superhydrophobic (SH) substrate comprising wells with a perforated mesh base was developed for simultaneous drop creation in a quick and convenient manner. In contrast to the method of pouring liquid directly over the SH wells, consistent liquid filling was readily achieved by a simple immersion approach.

View Article and Find Full Text PDF

Background: Microplate-based immunoassays are widely used in clinical and research settings to measure a broad range of biomarkers present in complex matrices. Assay variability within and between microplates can give rise to false-negative and false-positive results leading to incorrect conclusions. To date, the contribution of microplates to this variability remains poorly characterized and described.

View Article and Find Full Text PDF

Valves used to control liquid filling and draining processes from storage typically need to be actuated. Here, we show that similar flow enabling and restricting operations can be achieved through millimeter scale holes that function according to the amount of hydrostatic pressure applied without any other intervention. This phenomena is exhibited using receptacles where the base is made of either a hydrophilic or superhydrophobic substrate with hole sizes ranging from 1.

View Article and Find Full Text PDF

Drops with larger volumes placed over a superhydrophobic (SH) surface with a hole do not fall through unless they are evaporated to a size that is small enough. This feature offers the ability to preconcentrate samples for biochemical analysis. In this work, the influence of pinning on the behavior of drops placed on a 0.

View Article and Find Full Text PDF

In this work, 2 μL water drops are placed on substrates that are created to have a circular hydrophilic region bounded by superhydrophobicity so that they exhibit high contact angles. When the substrate is translated by a linear stepper actuator, the random force components present in the actuator are shown to cause the drop to rock resonantly. When the substrate is translated downward at inclination angles of up to 6° with respect to the horizontal, the contact angle hysteresis increases progressively to a limiting condition.

View Article and Find Full Text PDF

Captive bubbles that reside on superhydrophobic surfaces with plastrons move uncontrollably when tilted. A system based on creating moveable local apexes on flexible superhydrophobic foils is shown to allow controlled transport. Simulations done reveal that specific bubble transport speeds are needed to form concentration gradients suited for aerotaxis study and sensing.

View Article and Find Full Text PDF

Captive bubbles on a superhydrophobic (SH) surface have been shown to increase in volume via injection of air through the surrounding plastron. The experimental contact diameter against volume trends were found to follow that predicted by the Surface Evolver simulation generally but corresponded with the simulated data at contact angle (CA) = 158° when the volume was 20 μL but that at CA = 170° when the volume was increased to 180 μL. In this regime, there was a simultaneous outward movement of the contact line as well as a small reduction in the slope that the liquid-air interface makes with the horizontal as air was injected.

View Article and Find Full Text PDF

Superhydrophobic surfaces aid biochemical analysis by limiting sample loss. A system based on wells here tolerated tilting up to 20° and allowed air logic transfer with evidence of mixing. Conditions for intact transfer on 15 to 60 μL drops using compressed air pressure operation were also mapped.

View Article and Find Full Text PDF

The effect of hydrostatic pressure on 6 μL air bubbles formed on micropillar structured PDMS and silicone surfaces using a 2 mm diameter stainless steel tip retreated at 1 mm/s was investigated. Dimensional analysis of the tip retraction process showed the experiments to be conducted in the condition where fluid inertial forces are comparable in magnitude with surface tension forces, while viscous forces were lower. Larger bubbles could be left behind on the structured PDMS surface.

View Article and Find Full Text PDF