Publications by authors named "So Eui Kim"

This study constructed deep learning models using plain skull radiograph images to predict the accurate postnatal age of infants under 12 months. Utilizing the results of the trained deep learning models, it aimed to evaluate the feasibility of employing major changes visible in skull X-ray images for assessing postnatal cranial development through gradient-weighted class activation mapping. We developed DenseNet-121 and EfficientNet-v2-M convolutional neural network models to analyze 4933 skull X-ray images collected from 1343 infants.

View Article and Find Full Text PDF

Photoplethysmography (PPG) is a simple and cost-efficient technique that effectively measures cardiovascular response by detecting blood volume changes in a noninvasive manner. A practical challenge in the use of PPGs in real-world applications is noise reduction. PPG signals are likely to be compromised by various types of noise, such as scattering or motion artifacts, and removing such compounding noises using a monotonous method is not easy.

View Article and Find Full Text PDF

Pulse rate variability (PRV) refers to the change in the interval between pulses in the blood volume pulse (BVP) signal acquired using photoplethysmography (PPG). PRV is an indicator of the health status of an individual's autonomic nervous system. A representative method for measuring BVP is contact PPG (CPPG).

View Article and Find Full Text PDF

Oxygen saturation (SPO) is an important indicator of health, and is usually measured by placing a pulse oximeter in contact with a finger or earlobe. However, this method has a problem in that the skin and the sensor must be in contact, and an additional light source is required. To solve these problems, we propose a non-contact oxygen saturation measurement technique that uses a single RGB camera in an ambient light environment.

View Article and Find Full Text PDF

Photoplethysmography (PPG) is an optical measurement technique that detects changes in blood volume in the microvascular layer caused by the pressure generated by the heartbeat. To solve the inconvenience of contact PPG measurement, a remote PPG technology that can measure PPG in a non-contact way using a camera was developed. However, the remote PPG signal has a smaller pulsation component than the contact PPG signal, and its shape is blurred, so only heart rate information can be obtained.

View Article and Find Full Text PDF

Background: Lipoprotein-associated phospholipase A(2) (Lp-PLA(2)) is a lipoprotein-bound enzyme that can release atherogenic isoprostanes from esterified phospholipids and that may be involved in inflammation and atherosclerosis.

Objective: This study investigates the association between Lp-PLA(2) activity and coronary artery disease (CAD) in relation to oxidative stress markers, in particular urinary 8-epi-prostaglandin F(2alpha) (8-epi-PGF(2alpha)).

Design: We conducted a case-control study in which the cross-sectional relation between Lp-PLA(2) activity, lipoproteins, and oxidative stress markers was determined in 799 patients with angiographically confirmed CAD and 925 healthy controls.

View Article and Find Full Text PDF