Objective: To evaluate the efficacy of non-fixation versus fixation of meshes in laparoendoscopic repair of M3 inguinal hernias in terms of recurrence, postoperative pain, and surgical complications.
Summary Background Data: International guidelines recommend mesh fixation for large M3 inguinal hernias during laparoendoscopic repairs due to high recurrence rates. However, emerging experimental and registry data suggest that anatomically shaped, rigid and three-dimensional meshes may maintain stability without fixation.
Pol Przegl Chir
April 2024
Introduction: Parastomal hernia (PH) is a prevalent complication following ostomy formation, presenting significant challenges in surgical management. This study aims to validate the European Hernia Society classification for PH through the application of the Hybrid Parastomal Endoscopic Repair (HyPER) method. The study focuses on establishing the practical utility of the European Hernia Society classification in a clinical setting, particularly in guiding surgical approaches and improving patient outcomes.
View Article and Find Full Text PDFThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh in various directions and the strength of the mesh-tissue-staple junction.
View Article and Find Full Text PDFObjective: The aim of the ILAM (Individualized Laparoscopic Anatomical Mesh) study was to create and implant a fully individualized mesh based on CT scans, taking into account the published body of knowledge about the material and mechanical behavior of the implant for laparoscopic inguinal hernia repair.
Summary Background Data: The team creating and conducting this study consisted of surgeons and engineers. A specific project was made and divided into 4 phases.
Background: International guidelines of groin hernia treatment strongly recommend to fixate the mesh in large M3 medial defects during TAPP/TEP procedures. The main purpose of fixation is to decrease the recurrence rate which is alarmingly high in case of those defects. In 2022, a team consisting of hernia surgeons and scientists from universities of technology conducted an experimental study with the use of 3D groin model to verify the hypothesis that fixation is not necessary in above cases.
View Article and Find Full Text PDFIntroduction: Seromas refer to collections of fluid secreted into the so-called dead spaces when extensive dissection takes place. Various methods of preventing seroma have been reported in the literature but their outcomes are far from spectacular.
Aim: To verify the expected benefit on usage of IHSI (intra-operative hypertonic saline irrigation) in aspect of decreasing subcutaneous fluid secretion and decreased hospital stay in patients undergoing various abdominal wall reconstruction procedures.
Introduction: Correct surgical technique and perioperative care are two factors that can reduce the number of complications, improve treatment outcomes and shorten the length of hospital stay. The introduction of enhanced recovery protocols has changed the approach to patient care in some centers. However, there are significant differences among centers, and in some the standard of care has remained unchanged.
View Article and Find Full Text PDFIntroduction: The paper aims to establish the legal nature of the guidelines in the Polish legal system and the possible formal consequences of introducing such guidelines (litigation, professional responsibility) as well as practical implications concerning the method of treating patients.
Methods: Analysis is clarifying fundamental issues that largely determine the content of the study. The basic assumption is to analyze the legal nature of the prepared guidelines from the point of view of public law, i.
Background: Although international guidelines recommend not fixing the mesh in almost all cases of laparoendoscopic repairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of high-quality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials.
View Article and Find Full Text PDFBackground: Post-partum abdominal wall insufficiency (PPAWI) with rectus diastasis is present in over 30% of women after pregnancy. Little is known about how PPAWI affects the social, sexual life and self-esteem of patients. This study was designed to evaluate the safety of onlay mesh combined with abdominoplasty and its impact on the well-being of the patients.
View Article and Find Full Text PDFObjective: The aim of this study was to investigate the approach (open or laparoscopic) and mesh type (synthetic or biological) in ventral hernias in a clean setting.Summary of Background Data: The level of evidence on the optimal surgical approach and type of mesh in ventral hernia repair is still low.
Methods: Patients with a ventral abdominal hernia (diameter 4-10 cm) were included in this double-blind randomized controlled trial across 17 hospitals in 10 European countries.
Background: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall.
Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair.
Wideochir Inne Tech Maloinwazyjne
September 2018
Anterior abdominal wall reconstruction surgery in patients who have undergone multiple laparotomies is associated with a high risk of complications. For this reason, minimally invasive surgery techniques are used to avoid abdominal compartment syndrome, to enhance wound healing and to reduce postoperative pain and blood loss. This paper presents a case of a patient who was admitted to the Department of General Surgery in Puck Hospital as a result of extensive anterior abdominal wall deformation with an end descending colostomy.
View Article and Find Full Text PDFIn the therapy of an inguinal hernia, there is a huge variety in the way of treating and the choice of surgical technique. Practice shows that the intraoperative improvisation and surgeons' own modifications of the original techniques have become part of routine procedure. No mandatory hernia registration system causes the actual detailed herniology status in our country remains unknown.
View Article and Find Full Text PDFWideochir Inne Tech Maloinwazyjne
March 2017
Introduction: In 2012, a total of 56 647 inguinal hernia repairs were performed in Poland. However, the absence of a uniform hernia repair register obscures the current herniology status in Poland, especially regarding laparoendoscopic procedures.
Aim: To determine the awareness of laparoendoscopic procedures among Polish surgeons and to ascertain their everyday clinical practice.
Wideochir Inne Tech Maloinwazyjne
October 2016
More than 1 million inguinal hernia repairs are performed in Europe and the US annually. Although antibiotic prophylaxis is not required in clean, elective procedures, the routine use of implants (90% of inguinal hernia repairs are performed with mesh) makes the topic controversial. The European Hernia Society does not recommend routine antibiotic prophylaxis for elective inguinal hernia repairs.
View Article and Find Full Text PDFBackground: Prophylactic mesh-augmented reinforcement during closure of abdominal wall incisions has been proposed in patients with increased risk for development of incisional hernias (IHs). As part of the BioMesh consensus project, a systematic literature review has been performed to detect those studies where MAR was performed with a non-permanent absorbable mesh (biological or biosynthetic).
Methods: A computerized search was performed within 12 databases (Embase, Medline, Web-of-Science, Scopus, Cochrane, CINAHL, Pubmed publisher, Lilacs, Scielo, ScienceDirect, ProQuest, Google Scholar) with appropriate search terms.
Unlabelled: Laparoscopic ventral hernia repair has become popular technique. Every year, companies are introducing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients.
View Article and Find Full Text PDFBackground: Patients' need to improve outcomes and to reduce the number of complications triggers the development of new materials and surgery concepts. Currently, there are many implants and fixation systems dedicated for intraperitoneal onlay mesh procedure. The aim of this study was to compare two different mesh/fixation system concepts (PH: Physiomesh/Securestrap and VS: Ventralight ST/SorbaFix) for laparoscopic ventral hernia repair with respect to pain.
View Article and Find Full Text PDFWideochir Inne Tech Maloinwazyjne
April 2015
Introduction: Laparoscopic repair is becoming an increasingly popular alternative in the treatment of abdominal wall hernias. In spite of numerous studies evaluating this technique, indications for laparoscopic surgery have not been established. Similarly, implant selection and fixation techniques have not been unified and are the subject of scientific discussion.
View Article and Find Full Text PDFLangenbecks Arch Surg
October 2014
Background: The aim of this study was to evaluate whether the type of the mesh and proper surgical technique can influence the outcome of a tension-free hernia repair in a contaminated filed.
Materials And Methods: This study was based on the model of bacterial peritonitis in rats induced with a mixture composed of Escherichia coli and Bacteroides fragilis. Two animals were used as a control group without induced peritonitis and 10 animals with mesh implanted inside of the peritoneal cavity.