The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit.

View Article and Find Full Text PDF

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized.

View Article and Find Full Text PDF

Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.

View Article and Find Full Text PDF

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.

View Article and Find Full Text PDF

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci.

View Article and Find Full Text PDF

Prebunching via echo-enabled harmonic generation (EEHG) is an efficient way to reduce the radiator length and improve the longitudinal coherence as well as output stability in storage-ring-based free-electron lasers. We propose a conceptual design, which uses two straight sections to seed coherent extreme-ultraviolet (EUV) and soft X-ray emission with nearly MHz repetition rate. To take the large energy spread (10) of a storage ring into account and utilize the existing bending magnets between the two straight sections as the first chicane, we implement a special modeling tool, named EEHG optimizer.

View Article and Find Full Text PDF

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster.

View Article and Find Full Text PDF

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate.

View Article and Find Full Text PDF

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.

View Article and Find Full Text PDF
Article Synopsis
  • A new method for monitoring electron beam properties in real-time is developed, using Bragg-diffracted patterns to measure energy and spatial pointing jitter.
  • The technique isolates two types of fluctuations in the diffraction pattern: variations in the spacing of Bragg peaks (radial mode) and shifts of the entire pattern (drift mode).
  • This approach allows for simultaneous energy and spatial measurements during experiments, improving the quality and efficiency of ultrafast electron diffraction and microscopy techniques.
View Article and Find Full Text PDF

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC.

View Article and Find Full Text PDF

Novel features of the longitudinal instability of a single electron bunch circulating in a low-emittance electron storage ring are discussed. Measurements and numerical simulations, performed both in time and frequency domain, show a non-monotonic increase of the electron beam energy spread as a function of single bunch current, characterized by the presence of local minima and maxima, where a local minimum of the energy spread is interpreted as a higher-order microwave instability threshold. It is also shown that thresholds related to the same zero-intensity bunch length depend linearly on the accelerating radio frequency voltage.

View Article and Find Full Text PDF

The electron-positron collider DAPhiNE, the Italian Phi factory, has been recently upgraded in order to implement an innovative collision scheme based on large crossing angle, small beam sizes at the crossing point, and compensation of beam-beam interaction by means of sextupole pairs creating a "crab-waist" configuration in the interaction region. Experimental tests of the novel scheme exhibited an increase by a factor of 3 in the peak luminosity of the collider with respect to the performances reached before the upgrade. In this Letter we present the new collision scheme, discuss its advantages, describe the hardware modifications realized for the upgrade, and report the results of the experimental tests carried out during commissioning of the machine in the new configuration and standard operation for the users.

View Article and Find Full Text PDF

A new fast beam profile monitor has been developed at the Budker Institute of Nuclear Physics. This monitor is based on the Hamamatsu multianode photomultiplier with 16 anode strips and provides turn-by-turn measurement of the transverse beam profile. The device is equipped with an internal memory, which has enough capacity to store 131,072 samples of the beam profile.

View Article and Find Full Text PDF