Background: An innovative solution has been recently proposed for the treatment of heart failure with preserved ejection fraction (HFpEF), using a centrifugal mechanical circulatory support (MCS) device. We sought firstly to assess the hemocompatibility of the proposed device. HFpEF treatment requires the blood pump to operate at low blood flow rate (0.
View Article and Find Full Text PDFAlthough emulsion pumping is a subject of growing interest, a detailed analysis of the fluid dynamic phenomena occurring inside these machines is still lacking. Several computational investigations have been conducted to study centrifugal pumps carrying emulsion by analyzing their overall performance, but no studies involved the rheological behavior of such fluids. The purpose of this study is to perform a computational analysis of the performance and flow characteristics of a centrifugal pump with volute handling emulsions and oil-water mixtures at different water cuts modeled as a shear-thinning non-Newtonian fluid.
View Article and Find Full Text PDFAxial flow fans are used in many fields in order to ensure the mass and heat transfer from air, chiefly in the heating, ventilation and air conditioning industry (HVAC). A more proper understanding of the airflow behavior through the systems is necessary to manage and optimize the fan operation. Computational fluid dynamics (CFD) represents a real tool providing the ability to access flow structures in areas that measuring equipment cannot reach.
View Article and Find Full Text PDFExpert Rev Med Devices
August 2021
: The gap between the number of heart failure patients and the number of potential heart donors has never been larger than today, especially among the pediatric population. The use of mechanical circulatory support is seen as a potential alternative for clinicians to treat more patients. This treatment has proven its efficiency on short-term use.
View Article and Find Full Text PDFIn this study, we present a method for prediction of the drug-release profile based on the physical mechanisms that can intervene in drug release from a drug-carrier. The application presented here incorporates the effects of drug concentration and Reynolds number defining the circulating flow in the testing vein. The experimental data used relate to the release of diclofenac from samples of non-degradable polyurethane subjected to static and continuous flow.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
September 2020
Stenosis in the bifurcated coronary artery has attracted wide attention among the researchers. Many investigations have been carried out by means of Computational Fluid Dynamics (CFD) to better understand the physical mechanism inside the stenotic bifurcated artery. However, the main focus of the existing publications is limited to the variation of hemodynamic parameters affected by the stenosis and bifurcation structure.
View Article and Find Full Text PDF