Purpose: To investigate the effect of irradiation time and zirconia thickness using low power Er,Cr:YSGG laser irradia)on (for debonding purposes) on the thermal changes and shear bond strength (SBS) of resin-bonded 3% mol yIrium oxide stabilized tetragonal zirconia polycrystal (3YTZP) specimens.
Materials And Methods: 3Y-TZP slices of 0.5-, 2-, and 3- mm thick were used.
Eur J Prosthodont Restor Dent
November 2023
Introduction: Adjustments with diamond burs on the ceramic surface can affect its roughness and decrease flexural strength. This study evaluated the effect of polishing or glazing on the surface roughness and biaxial flexural strength of a zirconia-reinforced lithium silicate glass-ceramic upon adjustment with diamond burs.
Methods: Seventy disks were prepared according to ISO 6872 and divided into seven groups (n = 10) according to different adjustments and finishing processes.
Critical-sized cranial bone defects fail to re-ossify and require the surgical intervention of cranioplasty. To achieve superior bone healing in such cases, a hydrogel consisting of an interpenetrating network of collagen and elastin-like polypeptide to encapsulate bone morphogenetic protein-2 (BMP-2), doxycycline, and 45S5 Bioglass is developed. This hydrogel has an appropriate elastic modulus of 39 ± 2.
View Article and Find Full Text PDFObjectives: Previous studies have reported the fractal dimensional increment of glass-ceramic fracture surfaces. The objective of this study was to determine the relationship between fracture toughness and fractal dimensional increment of two dental glass-ceramics with different volume fraction of crystals and different fracture surface roughness.
Methods: Bar-shaped specimens were prepared from lithium disilicate (LDS) and nanofluorapatite (NFA) glass-ceramics.
This study aimed to characterize the surface topography, effect of polishing on surface roughness, residual stresses, and hardness in two glass-ceramic veneers. Fifty-two (52) upper incisors were collected, prepared, and scanned for ceramic veneers. Half of the teeth were restored with veneers made up of feldspathic ceramic (FE), and the other half with zirconia-reinforced lithium silicate ceramic (SZ).
View Article and Find Full Text PDFObjectives: Previous studies have shown that the fracture toughness of ceramics can be determined from the fractal dimensions (D) of their fracture surfaces and that the surface should be leveled to obtain an accurate D measurement. This study was to determine the effects of leveling operations and distance from the failure origin on the D values.
Methods: Twelve clinically failed zirconia implants from four different manufacturers: Axis Biodental (n=7), Z-Systems (n=3), Straumann (n=1), and Swiss Dental Solutions (n=1) were obtained from one of the authors and thoroughly cleaned.
The goals of this study are to evaluate the ability of the multicomponent collagen-elastin-like polypeptide (ELP)-Bioglass scaffolds to support osteogenesis of rat mesenchymal stem cells (rMSCs), demonstrate in vivo biocompatibility by subcutaneous implantation in Sprague-Dawley rats, monitor degradation noninvasively, and finally assess the scaffold's ability in healing critical-sized cranial bone defects. The collagen-ELP-Bioglass scaffold supports the in vitro osteogenic differentiation of rMSCs over a 3 week culture period. The cellular (rMSC-containing) or acellular scaffolds implanted in the subcutaneous pockets of rats do not cause any local or systemic toxic effects or tumors.
View Article and Find Full Text PDFBackground: Abrasive wear is one of the most common type of wear that not only affect teeth, as also dental restorations. Thus to investigate one of the etiological factors as tooth brushing procedure is clinical relevant in order to select the best material combination that may prevent damage of resin dental restoration's abrasion.
Aims: This study evaluated the influence of tooth brushing on mass loss and surface roughness of direct Venus (Vs) and indirect Signum (Sg) resin composites, with and without a surface sealant, Fortify (F).
Purpose: To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).
Materials And Methods: Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw.
Purpose: This in vitro study investigated the null hypothesis that metal-free crowns induce fracture loads and mechanical behavior similar to metal ceramic systems and to study the fracture pattern of ceramic crowns under compressive loads using finite element and fractography analyses.
Materials And Methods: Six groups (n = 8) with crowns from different systems were compared: conventional metal ceramic (Noritake) (CMC); modified metal ceramic (Noritake) (MMC); lithium disilicate-reinforced ceramic (IPS Empress II) (EMP); leucite-reinforced ceramic (Cergogold) (CERG); leucite fluoride-apatite reinforced ceramic (IPS d.Sign) (SIGN); and polymer crowns (Targis) (TARG).
The aim of this study was to evaluate, in vitro, the biaxial flexural strength (ISO 6872) of a feldspathic ceramic (VM7, Vita Zahnfabrik) coated with a resin cement with different thicknesses and polymerization mode. Control groups consisted in VM7 with and without acid etching with 10% hydrofluoric acid for 1 min. Experimental groups comprised VM7 etched, silanated and coated with Variolink II (Ivoclar Vivadent) cement, that was polymerized through the porcelain in light-cure and dual-cure modes, with thickness ≤150 µm or >150 µm.
View Article and Find Full Text PDFThis study examined the effect of 10% and 16% carbamide peroxide bleaching agents on the surface microhardness of micro-particulate feldspathic ceramics (VM7 and VM13, Vita Zahnfabrik). Forty specimens (8-mm diameter, 2-mm thickness) were divided into four groups (n=10): GI-VM7 + 10% Whiteness, G2-VM7 + 16% Whiteness, G3-VM13 + 10% and G4-VM13 + 16% Whiteness. The home-use bleaching agents were applied for 8 hours on 15 days, and the specimens were stored in distilled water at 37 degrees C.
View Article and Find Full Text PDFObjectives: Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.
Methods: Bar-shaped specimens of IA (n=45) and IZ (n=45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively.
The aim of this study was to assess the effect of bleaching agents (10% and 16% carbamide peroxide) on the roughness of two dental ceramics in vitro, and to analyze the surface by scanning electronic microscopy (SEM). Two bleaching agents (10% and 16%/Whiteness, FGM Gel) and two microparticle feldspathic ceramics (Vita VM7 and Vita VM13) were used. Forty disks of Vita VM7 and Vita VM13 ceramic were manufactured, measuring 4 mm in diameter and 4 mm high, in accordance with the manufacturers' recommendations, and were divided into 4 groups (n = 10): (1) VM7 + Whiteness 10%; (2) VM7 + Whiteness 16%; (3) VM13 + Whiteness 10%; (4) VM13 + Whiteness 16%.
View Article and Find Full Text PDFPurpose: To compare the flexural strength of two glass-infiltrated high-strength ceramics and two veneering glass-ceramics.
Materials And Methods: Four ceramic materials were tested: two glass-infiltrated high-strength ceramics used as framework in metal-free restorations [In-Ceram Zirconia IZ (Gr1) and In-Ceram Alumina IA (Gr2)], and two glass-ceramics used as veneering material in metal-free restorations [Vita VM7 (Gr3) and Vitadur-alpha (Gr4)]. Bar specimens (25 x 5 x 2 mm3) made from core ceramics, alumina, and zirconia/alumina composites were prepared and applied to a silicone mold, which rested on a base from a gypsum die material.